Anritsu S251C manual Printing a Screen

Page 43

Chapter 3 Getting Started

Printing

Printing is accomplished by selecting an available printer and pressing the print key as de- scribed below. Refer to the particular printer operating manual for specific printer settings.

Printing a Screen

Step 1. Connect the printer as shown in Figure 3-4.

Site Master S251C

 

 

ESCAPE

1

2

CLEAR

START

AUTO

 

CAL

SCALE

 

3

4

 

SAVE

RECALL

 

SETUP

SETUP

 

5

6

 

LIMIT

MARKER

 

7

8

ENTER

 

SAVE

RECALL

RUN

DISPLAY

DISPLAY

HOLD

9

0

+/-

ON

PRINT

SYS

OFF

.

 

 

MODE

FREQ/DIST

AMPLITUDE

SWEEP

SEIKO

PRINTER

SERIAL CABLE 2000-1012

HP 350

DESKJET

SERIAL-TO-PARALLEL INTERFACE CABLE 2000-753

Figure 3-4-. Site Master Printer Setup

Step 2. Obtain the desired measurement display

Step 3. Press the SYS key and the OPTIONS soft key (Figure 3-5) .

OPTIONS

Site Master S251C

OPTIONS

CLOCK

SELF TEST

STATUS

 

 

ESCAPE

 

1

2

CLEAR

 

 

 

START

AUTO

 

 

CAL

SCALE

 

 

3

4

 

 

SAVE

RECALL

 

 

SETUP

SETUP

 

 

5

6

 

 

LIMIT

MARKER

 

 

7

8

ENTER

 

 

 

SAVE

RECALL

RUN

SYS

DISPLAY

DISPLAY

HOLD

 

9

0

+/-

 

ON

PRINT

SYS

 

OFF

.

 

 

 

 

 

 

MODEFREQ/DIST AMPLITUDE SWEEP

Figure 3-5-. SYS Key and OPTIONS Soft Key

3-8

Image 43
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Introduction Standard AccessoriesDescription Options Optional AccessoriesPerformance Specifications Description Site Master Performance Specifications 2 ESD Precautions Preventive MaintenanceAnnual Verification Anritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude MODE=POWER Monitor Softkeys Power Monitor Menu OptionMODE=RF Source Softkeys RF Source MenuLimit Segment 1 Segment SYS Self Test SymbolsSelf Test Errors Error CodesERRORD2 Range ErrorsCharging the Battery in the Optional Charger Battery InformationCharging a New Battery Charging the Battery in the Site MasterBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Calibration Procedure Single PortRF in Test Port RF OUT Test Port Calibration Procedure Dual PortSave and Recall a Setup Setting the ScaleSave and Recall a Display Recalling a Display Changing the Units Set the Distance and Cable TypeChanging the Display Language Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals One Port MeasurementsMeasurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test Procedures2is an example of a typical system return loss trace Insertion Loss Measurement Procedure Cable Loss ModeType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Procedure DTF-Return Loss Mode Distance-To-Fault DTF Transmission Line TestProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Introduction Two Port MeasurementsTMA-S TMA MeasurementsTMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement 15. System Isolation Antenna to Antenna IsolationAntenna-to-Antenna Isolation Measurement Quency settings for common systems21/4-22 System Requirements FeaturesCommunication Port Setting InstallationInterface Cable Installation Using Software ToolsDownloading Traces from the Site Master Plot Properties Plot CaptureSaving Traces Trace Overlay or Plot OverlaySaving a Plot to a Spreadsheet Custom Cable ListPrinting Formats Creating a DatabaseAppendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Examples Appendix B WindowingAppendix B Windowing B-4