Anritsu S251C manual Performance Specifications 2

Page 12

 

Chapter 1 General Information

Table 1-2.Performance Specifications (2 of 2)

 

 

 

Cable Insertion Loss:

 

Range

0.00 to 54.00 dB

Resolution

0.01 dB

Bias Tee

 

input voltage:

12.5 to 15.0 Vdc

output current:

270 ma maximum surge, 25 ms

 

240 ma maximum steady

General

 

Internal Memory:

 

Trace Memory

200 maximum

Instrument config.

10 setup locations with associated calibration

RS-232

9 pin D-sub, three wire serial

Electromagnetic Compatibility

Meets European Community requirements for

 

CE marking

Power Supply:

 

External DC Input

+11 to +15 Vdc, 1250 mA max.

Temperature:

 

Storage

–20° C to 75° C

Operation

0° C to 50° C

Weight:

1.82 kg (4.0 pounds)

Dimensions:

25.4 x 17.8 x 6.1 cm

 

(10 x 7 x 2.4 inches)

*±2 ppm/ ￿°C from 25°C

**Fault location is accomplished by inverse Fourier Transformation of data taken with the Site Master. Resolution and maximum range depend on the number of frequency data points, frequency sweep range and relative propagation veloc- ity of the cable being tested.

***Immunity measurement is made in CW mode with incoming interfering signal exactly at the same frequency (worst case situation). Typical immunity is better when swept frequency is used.

1 - 5

Image 12
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Standard Accessories IntroductionDescription Optional Accessories OptionsPerformance Specifications Description Site Master Performance Specifications 2 Preventive Maintenance ESD PrecautionsAnnual Verification Anritsu Service Centers Test Connector Panel Chapter Functions and OperationsFront Panel Overview Active Function Block Soft KeysFunction Hard Keys ModeKeypad Hard Keys ClearAuto Soft Keys MODE=FREQ FREQ/DIST SoftkeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude Power Monitor Menu Option MODE=POWER Monitor SoftkeysRF Source Menu MODE=RF Source SoftkeysLimit Segment 1 Segment SYS Symbols Self TestError Codes Self Test ErrorsRange Errors ERRORD2Battery Information Charging a New BatteryCharging the Battery in the Site Master Charging the Battery in the Optional ChargerBattery Charge Indicator Battery LifeImportant Battery Information Power On Procedure Chapter Getting StartedSelect the Frequency or Distance CalibrationCalibration Procedure Single Port CalibrationCalibration Procedure Dual Port RF in Test Port RF OUT Test PortSetting the Scale Save and Recall a SetupSave and Recall a Display Recalling a Display Set the Distance and Cable Type Changing the UnitsChanging the Display Language Printing Printing a ScreenPrinter Switch Settings PrinterUsing the Soft Carrying Case Using the Site Master Soft Carrying CaseOne Port Measurements Line Sweep FundamentalsInformation Required for a Line Sweep MeasurementsTypical Line Sweep Test Procedures System Return Loss Measurement2is an example of a typical system return loss trace Procedure Cable Loss Mode Insertion Loss MeasurementType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Distance-To-Fault DTF Transmission Line Test Procedure DTF-Return Loss ModeProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Two Port Measurements IntroductionTMA Measurements TMA-STMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement Antenna to Antenna Isolation 15. System IsolationQuency settings for common systems Antenna-to-Antenna Isolation Measurement21/4-22 Features System RequirementsInstallation Communication Port SettingUsing Software Tools Interface Cable InstallationDownloading Traces from the Site Master Plot Capture Plot PropertiesTrace Overlay or Plot Overlay Saving TracesCustom Cable List Saving a Plot to a SpreadsheetCreating a Database Printing FormatsCoaxial Cable Technical Data Appendix a Reference DataAppendix a Reference Data A-4 Appendix B Windowing ExamplesAppendix B Windowing B-4