Chapter 2 Functions and Operations

 

AMPLITUDE

Displays the amplitude or scale menu depending on the measurement mode.

 

Amplitude

Provides for changing the display scale. Selected values may be changed using

 

Menu

the Up/Down arrow key or keypad.

 

 

Choosing AMPLITUDE in FREQ or DTF measurement modes causes the soft

 

 

keys, below, to be displayed and the corresponding values to be shown in the

 

 

message area.

 

 

￿ TOP — Opens the top parameter for data entry and provides for setting the

 

 

top scale value. Press ENTER when data entry is complete.

 

 

￿ BOTTOM — Opens the bottom parameter for data entry and provides for set-

 

 

ting the bottom scale value. Press ENTER when data entry is complete.

 

SWEEP

Displays the Sweep function soft key menu for the current operating mode.

 

 

Sweep Menu

Provides for changing the display resolution, single or continuous sweep, and

 

 

access to the Trace Math functions.

 

 

Choosing SWEEP in FREQ or DTF measurement modes causes the soft keys

 

 

 

 

below to be displayed.

 

 

￿ RESOLUTION — Opens the display to change the resolution. Choose 130,

 

 

259, or 517 data points. (In DTF mode, resolution can be adjusted through

 

 

the DTF-AID table.)

 

 

￿ SINGLE SWEEP — Toggles the sweep between single sweep and continu-

 

 

ous sweep. In single sweep mode, each sweep must be activated by the

 

 

RUN/HOLD button.

 

 

￿ TRACE MATH — Opens up the Trace Math functions (trace-memory or

 

 

trace+memory) for comparison of the real time trace in the display with any

 

 

of the traces from memory. (Not available in DTF mode.)

 

 

￿ TRACE OVERLAY — Opens up the Trace Overlay functions menu to allow

 

 

the current trace to be displayed at the same time as a trace in memory.

 

 

Choose ON or OFF and SELECT TRACE to select the trace from memory to

 

 

perform trace overlay.

 

2 - 9

Image 24
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Standard Accessories IntroductionDescription Optional Accessories OptionsPerformance Specifications Description Site Master Performance Specifications 2 Preventive Maintenance ESD PrecautionsAnnual Verification Anritsu Service Centers Test Connector Panel Chapter Functions and OperationsFront Panel Overview Active Function Block Soft KeysFunction Hard Keys ModeKeypad Hard Keys ClearAuto Soft Keys MODE=FREQ FREQ/DIST SoftkeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude Power Monitor Menu Option MODE=POWER Monitor SoftkeysRF Source Menu MODE=RF Source SoftkeysLimit Segment 1 Segment SYS Symbols Self TestError Codes Self Test ErrorsRange Errors ERRORD2Battery Information Charging a New BatteryCharging the Battery in the Site Master Charging the Battery in the Optional ChargerBattery Charge Indicator Battery LifeImportant Battery Information Power On Procedure Chapter Getting StartedSelect the Frequency or Distance CalibrationCalibration Procedure Single Port CalibrationCalibration Procedure Dual Port RF in Test Port RF OUT Test PortSetting the Scale Save and Recall a SetupSave and Recall a Display Recalling a Display Set the Distance and Cable Type Changing the UnitsChanging the Display Language Printing Printing a ScreenPrinter Switch Settings PrinterUsing the Soft Carrying Case Using the Site Master Soft Carrying CaseOne Port Measurements Line Sweep FundamentalsInformation Required for a Line Sweep MeasurementsTypical Line Sweep Test Procedures System Return Loss Measurement2is an example of a typical system return loss trace Procedure Cable Loss Mode Insertion Loss MeasurementType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Distance-To-Fault DTF Transmission Line Test Procedure DTF-Return Loss ModeProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Two Port Measurements IntroductionTMA Measurements TMA-STMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement Antenna to Antenna Isolation 15. System IsolationQuency settings for common systems Antenna-to-Antenna Isolation Measurement21/4-22 Features System RequirementsInstallation Communication Port SettingUsing Software Tools Interface Cable InstallationDownloading Traces from the Site Master Plot Capture Plot PropertiesTrace Overlay or Plot Overlay Saving TracesCustom Cable List Saving a Plot to a SpreadsheetCreating a Database Printing FormatsCoaxial Cable Technical Data Appendix a Reference DataAppendix a Reference Data A-4 Appendix B Windowing ExamplesAppendix B Windowing B-4