Anritsu S251C manual Appendix a Reference Data, Coaxial Cable Technical Data

Page 74

Appendix A

Reference Data

Coaxial Cable Technical Data

Table A-1 provides a standard listing of common coaxial cables along with their Relative Propagation Velocity and Nominal Attenuation values in dB/m @1000, 2000, and 2500 MHz.

Table A-1.Coaxial Cable Technical Data (1 of 3)

 

 

 

 

 

Relative

Nominal

Nominal

Nominal

 

 

Attenuation

Attenuation

Attenuation

Manufacturer

Cable Type

Propagation

dB/m @

dB/m @

dB/m @

 

 

Velocity (Vf)

 

 

1000 MHz

2000 MHz

2500 MHz

 

 

 

 

 

 

 

 

 

Andrew

FSJ1-50A

0.84

0.197

0.285

0.323

 

 

 

 

 

 

Andrew

FSJ2-50

0.83

0.134

0.196

0.224

 

 

 

 

 

 

Andrew

FSJ4-50B

0.81

0.119

0.176

0.202

 

 

 

 

 

 

Andrew

LDF4-50A

0.88

0.077

0.113

0.133

 

 

 

 

 

 

Andrew

LDF5-50A

0.89

0.043

0.064

0.077

 

 

 

 

 

 

Andrew

LDF6-50

0.89

0.032

0.048

0.056

 

 

 

 

 

 

Andrew

LDF7-50A

0.88

0.027

0.041

0.047

 

 

 

 

 

 

Andrew

LDF12-50

0.88

0.022

0.035

N/A

 

 

 

 

 

 

Andrew

HJ4-50

0.914

0.087

0.126

0.15

 

 

 

 

 

 

Andrew

HJ4.5-50

0.92

0.054

0.079

0.084

 

 

 

 

 

 

Andrew

HJ5-50

0.916

0.042

0.063

0.07

 

 

 

 

 

 

Andrew

HJ7-50A

0.921

0.023

0.034

0.04

 

 

 

 

 

 

Andrew

HJ12-50

0.931

0.019

0.029

N/A

 

 

 

 

 

 

Belden

RG8, 8A

0.659

0.262

N/A

N/A

 

 

 

 

 

 

Belden

RG9, 9A

0.659

0.289

N/A

N/A

 

 

 

 

 

 

Belden

RG17, 17A

0.659

0.18

N/A

N/A

 

 

 

 

 

 

Belden

RG55, 55A, 55B

0.659

0.541

N/A

N/A

 

 

 

 

 

 

Belden

RG58, 58B

0.659

0.558

N/A

N/A

 

 

 

 

 

 

Belden

RG58A, 58C

0.659

0.787

N/A

N/A

 

 

 

 

 

 

Belden

RG142

0.659

0.443

N/A

N/A

 

 

 

 

 

 

Belden

RG174

0.659

0.984

N/A

N/A

 

 

 

 

 

 

Belden

RG178B

0.659

1.509

N/A

N/A

 

 

 

 

 

 

Belden

RG188

0.659

1.017

N/A

N/A

 

 

 

 

 

 

Belden

RG213

0.659

0.292

N/A

N/A

A-1

Image 74
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Description Standard AccessoriesIntroduction Optional Accessories OptionsPerformance Specifications Description Site Master Performance Specifications 2 Preventive Maintenance ESD PrecautionsAnnual Verification Anritsu Service Centers Test Connector Panel Chapter Functions and OperationsFront Panel Overview Active Function Block Soft KeysFunction Hard Keys ModeKeypad Hard Keys ClearAuto Soft Keys MODE=FREQ FREQ/DIST SoftkeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude Power Monitor Menu Option MODE=POWER Monitor SoftkeysRF Source Menu MODE=RF Source SoftkeysLimit Segment 1 Segment SYS Symbols Self TestError Codes Self Test ErrorsRange Errors ERRORD2Charging the Battery in the Site Master Battery InformationCharging a New Battery Charging the Battery in the Optional ChargerBattery Charge Indicator Battery LifeImportant Battery Information Power On Procedure Chapter Getting StartedSelect the Frequency or Distance CalibrationCalibration Procedure Single Port CalibrationCalibration Procedure Dual Port RF in Test Port RF OUT Test PortSave and Recall a Display Setting the ScaleSave and Recall a Setup Recalling a Display Changing the Display Language Set the Distance and Cable TypeChanging the Units Printing Printing a ScreenPrinter Switch Settings PrinterUsing the Soft Carrying Case Using the Site Master Soft Carrying CaseOne Port Measurements Line Sweep FundamentalsInformation Required for a Line Sweep MeasurementsTypical Line Sweep Test Procedures System Return Loss Measurement2is an example of a typical system return loss trace Procedure Cable Loss Mode Insertion Loss MeasurementType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Distance-To-Fault DTF Transmission Line Test Procedure DTF-Return Loss ModeProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Two Port Measurements IntroductionTMA Measurements TMA-STMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement Antenna to Antenna Isolation 15. System IsolationQuency settings for common systems Antenna-to-Antenna Isolation Measurement21/4-22 Features System RequirementsInstallation Communication Port SettingDownloading Traces from the Site Master Using Software ToolsInterface Cable Installation Plot Capture Plot PropertiesTrace Overlay or Plot Overlay Saving TracesCustom Cable List Saving a Plot to a SpreadsheetCreating a Database Printing FormatsCoaxial Cable Technical Data Appendix a Reference DataAppendix a Reference Data A-4 Appendix B Windowing ExamplesAppendix B Windowing B-4