Anritsu S331C, S113C, S332C, S114C manual Printing a Screen

Page 51

Chapter 3 Getting Started

Printing

Printing is accomplished by selecting an available printer and pressing the print key as de- scribed below. Refer to the particular printer operating manual for specific printer settings.

Printing a Screen

Step 1. Connect the printer as shown in Figure 3-4.

Site Master S332C

 

 

ESCAPE

1

2

CLEAR

START

AUTO

 

CAL

SCALE

 

3

4

 

SAVE

RECALL

 

SETUP

SETUP

 

5

6

 

LIMIT

MARKER

 

 

 

ENTER

7 8

SAVE RECALL RUN

DISPLAY DISPLAY HOLD

9 0 +/-

SEIKO

PRINTER

SERIAL CABLE 2000-1012

HP 350

DESKJET

ON PRINT

OFF.

MODE

FREQ/DIST

AMPLITUDE

SWEEP

SYS

SERIAL-TO-PARALLEL

INTERFACE CABLE 2000-753

Figure 3-4-. Site Master Printer Setup

Step 2. Obtain the desired measurement display

Step 3. Press the SYS key and the OPTIONS soft key (Figure 3-5) .

OPTIONS

Site Master S332C

OPTIONS

CLOCK

SELF TEST

STATUS

 

 

ESCAPE

 

1

2

CLEAR

 

 

 

START

AUTO

 

 

CAL

SCALE

 

 

3

4

 

 

SAVE

RECALL

 

 

SETUP

SETUP

 

 

5

6

 

 

LIMIT

MARKER

 

 

7

8

ENTER

 

 

 

SAVE

RECALL

RUN

SYS

DISPLAY

DISPLAY

HOLD

 

9

0

+/-

 

ON

PRINT

SYS

 

OFF

.

 

 

 

 

 

 

MODE

FREQ/DIST

AMPLITUDE

SWEEP

Figure 3-5-. SYS Key and OPTIONS Soft Key

3-10

Image 51
Contents Users Guide Warranty Page Table of Contents Power Measurement Iii/iv Page Description Standard AccessoriesChapter General Information IntroductionOptions Optional AccessoriesPerformance Specifications Description Site Master Spectrum Analyzer Calibration Preventive MaintenanceInstaCal Module Annual VerificationAnritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys MODE=SPECTRUM Analyzer FREQ/DIST Amplitude Softkeys Power Monitor Mode Soft Key Labels Functions and Operations Functions and Operations Amplitude RUN/HOLD button Functions and Operations Power Monitor Menu Functions and Operations Limit SYS Self Test SymbolsError Codes Self Test ErrorsError Message ERRORD2 Range ErrorsInstalled InstaCal Error MessagesError MessageDescription Charging the Battery in the Optional Charger Battery InformationCharging a New Battery Charging the Battery in the Site MasterBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Verification Trace Characteristics in Return Loss ModeCalibration Manual Calibration ProcedureInstaCal Module Verification Termination MethodOffset Method Calibration with the Test Port Extension Cable InstaCal Module Calibration ProcedureAuto Scale Setting the ScaleSave and Recall a Setup Saving a SetupRecalling a Display Recalling a SetupSave and Recall a Display Saving a DisplaySet the Distance and Cable Type Changing the UnitsChanging the Display Language Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals Chapter Cable & Antenna MeasurementsCable & Antenna Measurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test ProceduresInsertion Loss Measurement Procedure Cable Loss ModeSet M1 to Marker to Peak Set M2 to Marker to Valley Typical Transmission Line Cable Loss Trace Procedure Return Loss ModeTypical Return Loss Trace Distance-To-Fault DTF Transmission Line Test Shows an example of a typical DTF return loss trace Procedure DTF-SWR ModeAntenna Subsystem Return Loss Test 11/4-12 Page Occupied Bandwidth Chapter Spectrum Analyzer MeasurementsChannel Power Measurement with the Site Master Channel Power MeasurementProcedure Example Acpr Specification Adjacent Channel Power MeasurementCW Wave Out-of-Band Spurious Emission Measurements In-Band/Out-of-Channel Measurements Field Strength Measurement VdBV PdBm Antenna CalculationsPage Power Measurement Chapter Power MeasurementDisplaying Relative Power Features Chapter Site Master Software ToolsSystem Requirements Communication Port Setting InstallationUsing Software Tools Interface Cable InstallationDownloading Traces from the Site Master Graph Titles Display ModePlot Capture Plot PropertiesMisc Trace Overlay or Plot OverlaySaving Traces MarkersCustom Cable List Saving a Plot to a SpreadsheetCreating a Custom Cable List Entering Antenna Factors Uploading a Cable ListQuerying the Site Master Cable List Uploading Antenna Factors Creating a DatabasePrinting Formats Appendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Page Appendix B Windowing IntroductionExamples Appendix B Windowing B-4 Page

S113C, S332C, S114C, S331C specifications

Anritsu, a leader in test and measurement solutions, offers a range of handheld tools that cater to the needs of professionals in the RF and microwave industries. Among these tools are the Anritsu S331C, S114C, S332C, and S113C, each designed with unique features and technologies that make them suitable for various applications.

The Anritsu S331C is a Cable and Antenna Analyzer that is particularly valued for its accuracy and ease of use. It operates within a frequency range of 3 MHz to 4 GHz, making it applicable for both wireless and microwave communication systems. One of its standout features is the built-in Time Domain Reflectometry (TDR) function, which allows technicians to pinpoint faults in cables quickly. The S331C's intuitive touch-screen interface ensures seamless operation, while its lightweight design allows for portability in the field.

On the other hand, the Anritsu S114C is a versatile handheld RF power meter that can measure a wide range of power levels and frequencies. Its exceptional measurement accuracy and broad dynamic range make it suitable for various applications, from network testing to maintenance. It supports both peak and average power measurements, providing users with the flexibility to adapt to different testing scenarios. The S114C also features a memory function that allows users to store and recall measurement data easily.

The S332C model is designed for more advanced applications, offering vector network analysis capabilities. Operating within a frequency range of 5 kHz to 4 GHz, it is used for characterizing components such as filters, amplifiers, and cables. The S332C features a high-resolution display and supports automated measurements, making it a powerful tool for engineers involved in the design and validation of RF components.

Lastly, the Anritsu S113C is an excellent choice for professionals requiring a compact and efficient solution for insertion loss and return loss measurements. This analyzer covers a frequency range of 5 kHz to 4 GHz and is especially suited for testing antennas and RF components. The S113C's lightweight design, combined with its user-friendly interface, allows operators to conduct measurements easily in various environments, ensuring high performance and reliability.

In summary, the Anritsu S331C, S114C, S332C, and S113C represent a comprehensive suite of handheld analyzers that cater to diverse needs in the RF and microwave sectors. With features like TDR function, RF power measurements, vector network analysis, and a focus on portability, these instruments are essential tools for professionals looking to enhance their testing capabilities and ensure high-quality network performance.