AMPLITUDE

Displays the amplitude or scale menu depending on the measurement mode.

Amplitude

Provides for changing the display scale. Selected values may be changed using

Menu

the Up/Down arrow key or keypad.

 

Choosing AMPLITUDE in FREQ or DTF measurement modes causes the soft

 

keys, below, to be displayed and the corresponding values to be shown in the

 

message area.

 

￿ TOP — Opens the top parameter for data entry and provides for setting the

 

top scale value. Press ENTER when data entry is complete.

 

￿ BOTTOM — Opens the bottom parameter for data entry and provides for set-

 

ting the bottom scale value. Press ENTER when data entry is complete.

 

Choosing AMPLITUDE in SPECTRUM ANALYZER mode causes the soft keys,

 

below, to be displayed and the corresponding values to be shown in the message

 

area.

 

￿ REF LEVEL — Activates the amplitude reference level function.

 

￿ SCALE — Activates the scale function in a 2 through 15 dB logarithmic am-

 

plitude scale.

 

￿ ATTEN — Sets the Anritsu input attenuator so that it is either coupled auto-

 

matically to the reference level (AUTO) or manually adjustable (MANUAL).

 

￿ UNITS — Choose from the menu of amplitude related units. Selection of

 

dBm sets absolute decibels relative to 1 mW as the amplitude unit. Selection

 

of dBV, dBmV or dB￿V sets absolute decibels relative to 1 volt, 1 millivolt,

 

or 1 microvolt respectively as the amplitude unit.

2-12

Image 27 Contents
Users Guide Warranty Page Table of Contents Power Measurement Iii/iv Page Description Standard AccessoriesChapter General Information IntroductionOptions Optional AccessoriesPerformance Specifications Description Site Master Spectrum Analyzer Calibration Preventive MaintenanceInstaCal Module Annual VerificationAnritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys MODE=SPECTRUM Analyzer FREQ/DIST Amplitude Softkeys Power Monitor Mode Soft Key Labels Functions and Operations Functions and Operations Amplitude RUN/HOLD button Functions and Operations Power Monitor Menu Functions and Operations Limit SYS Self Test SymbolsError Codes Self Test ErrorsError Message ERRORD2 Range ErrorsInstalled InstaCal Error MessagesError MessageDescription Charging the Battery in the Optional Charger Battery InformationCharging a New Battery Charging the Battery in the Site MasterBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Verification Trace Characteristics in Return Loss ModeCalibration Manual Calibration ProcedureInstaCal Module Verification Termination MethodOffset Method Calibration with the Test Port Extension Cable InstaCal Module Calibration ProcedureAuto Scale Setting the ScaleSave and Recall a Setup Saving a SetupRecalling a Display Recalling a SetupSave and Recall a Display Saving a DisplaySet the Distance and Cable Type Changing the UnitsChanging the Display Language Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals Chapter Cable & Antenna MeasurementsCable & Antenna Measurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test ProceduresInsertion Loss Measurement Procedure Cable Loss ModeSet M1 to Marker to Peak Set M2 to Marker to Valley Typical Transmission Line Cable Loss Trace Procedure Return Loss ModeTypical Return Loss Trace Distance-To-Fault DTF Transmission Line Test Shows an example of a typical DTF return loss trace Procedure DTF-SWR ModeAntenna Subsystem Return Loss Test 11/4-12 Page Occupied Bandwidth Chapter Spectrum Analyzer MeasurementsChannel Power Measurement with the Site Master Channel Power MeasurementProcedure Example Acpr Specification Adjacent Channel Power MeasurementCW Wave Out-of-Band Spurious Emission Measurements In-Band/Out-of-Channel Measurements Field Strength Measurement VdBV PdBm Antenna CalculationsPage Power Measurement Chapter Power MeasurementDisplaying Relative Power Features Chapter Site Master Software ToolsSystem Requirements Communication Port Setting InstallationUsing Software Tools Interface Cable InstallationDownloading Traces from the Site Master Graph Titles Display ModePlot Capture Plot PropertiesMisc Trace Overlay or Plot OverlaySaving Traces MarkersCustom Cable List Saving a Plot to a SpreadsheetCreating a Custom Cable List Entering Antenna Factors Uploading a Cable ListQuerying the Site Master Cable List Uploading Antenna Factors Creating a DatabasePrinting Formats Appendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Page Appendix B Windowing IntroductionExamples Appendix B Windowing B-4 Page