Cornelius TP01070 manual Back Block

Page 12

FlavorFusion® Training Manual

5.Tilt the valve removal tool up to release the latch.

 

Back Block

Valve Removal Tool

Release Latch

FIGURE 15

FIGURE 16

6.Pull the valve off the back block.

FIGURE 17

7.Push the valve on the back block and push up on the back block release latch to replace the valve.

FIGURE 18

Publication Number: TP01070

- 8 -

© 2004-2007, IMI Cornelius Inc.

Image 12
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Product Overview Theory of OperationSystem Requirements Syrup brands psi min Syrup bonus psi maxProgramming Mode Flashing Sequences ProgrammingDispense Type 1, Carbonated water dispense Solid LED Setting Water Flow Rate Valve with Flow AdjustersAdjusting Syrup/Water Ratio Brix Setting a Button to Dispense Non-carbonated Water OnlySetting a Button to Dispense Carbonated Water Only Timed Dispense ProcedureDisassembly MechanicalControl Box Components Valve Removal Back Block Valve Service Carbonator TankMotor Removal System Plumbing Diagram Plumbing Diagram Flavor Fusion -16 BrandInterface Board Detail Interface Board and Harness PIN-OUT DetailPOINT-POINT Wiring Diagram FusionLadder Type Wiring Diagram Wiring Ladder Schematic 115V- Flavor FusionTroubleshooting PCBDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Diagnostics Guide for the Main Control Board see Figure ConditionIMI Cornelius Inc