Cornelius TP01070 manual Valve Service, Carbonator Tank, Motor Removal

Page 13

FlavorFusion®/FlavorOverload Training Manual

VALVE SERVICE

NOTE: Before servicing the valve the BIB connector must be disconnected an the pressure must be relieved.

1.Remove the locking screw after removing the valve from its mounting block.

2.

Twist the solenoid 90o.

Spring Clip

Locking Screw

3.Pull the solenoid loose from the valve body.

4.To remove the tubing squeeze the spring clip together and pull off.

FIGURE 19

CARBONATOR TANK

Always disconnect water and CO2 and relieve the carbonator pressure before removing the car- bonator probe.

MOTOR REMOVAL

NOTE: Apply anti seizing lubricant to the threads of mounting bolts when service is required.

Grounding Connection/

Upper and Lower Level

CO2 Inlet

Control Probes

Relief

Valve

FIGURE 20

Heater, Agitation

Heater Spring

Motor, & Gear Box

Motor

Mounting

Screws

FIGURE 21

© 2004-2007, IMI Cornelius Inc.

- 9 -

Publication Number: TP01070

Image 13
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Theory of Operation Product OverviewSyrup brands psi min Syrup bonus psi max System RequirementsProgramming Programming Mode Flashing SequencesDispense Type 1, Carbonated water dispense Solid LED Valve with Flow Adjusters Setting Water Flow RateSetting a Button to Dispense Non-carbonated Water Only Adjusting Syrup/Water Ratio BrixSetting a Button to Dispense Carbonated Water Only Timed Dispense ProcedureMechanical DisassemblyControl Box Components Valve Removal Back Block Carbonator Tank Valve ServiceMotor Removal System Plumbing Diagram Flavor Fusion -16 Brand Plumbing DiagramInterface Board and Harness PIN-OUT Detail Interface Board DetailFusion POINT-POINT Wiring DiagramWiring Ladder Schematic 115V- Flavor Fusion Ladder Type Wiring DiagramPCB TroubleshootingDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Condition Diagnostics Guide for the Main Control Board see FigureIMI Cornelius Inc