Cornelius TP01070 manual Adjusting Syrup/Water Ratio Brix, Timed Dispense Procedure

Page 9

FlavorFusion®/FlavorOverload Training Manual

FIGURE 3

Adjusting Syrup/Water Ratio (Brix)

Timed Dispense Procedure

1.Enter programming mode for the valve block by simultaneously pressing and holding both programming buttons for 4 seconds (see FIGURE 3). The LED’s for flavors 1-4 should flash off and then back on. The drink icon should turn off.

2.Set the valve block to a 4 second pour mode by simultaneously pressing and holding Flavor 1 and Flavor 4 buttons until the flash pattern for all for buttons changes.

3.Place the water end of the ratio cup under the appropriate nozzle and press the left program button for a 4 second dispense of carbonated water. (Push the right program button for still water pour.)

4.Place the syrup end of the ratio cup under the nozzle and press the appropriate flavor button for a 4 second dispense of syrup. The fill line should be the same for both water and the syrup. Adjust the syrup flow control if necessary, then empty cup and repeat steps 3 and 4.

5.Repeat for all syrups in valve bank.

6.Exit 4 second pour mode by simultaneously pressing and holding Flavor 1 and Flavor 4 buttons until the flash pattern for all for buttons changes.

7.Exit programming mode by simultaneously pressing and holding both programming buttons for 4 seconds.

Setting a Button to Dispense Non-carbonated Water Only

1.Program the designated button to dispense non-carbonated water (see Programming Mode.)

2.Do not connect a syrup source to the inlet circuit of the designated button (1-14 or A1-A2.) If circuit 1 through 14 is chosen leave the coldplate inlet circuit plugged with the red cap. If circuit A1 or A2 is chosen, plug the end of the inlet tube with a red cap from the coldplate, or with tape.

Setting a Button to Dispense Carbonated Water Only

1.Program the designated button to dispense carbonated water (see Programming Mode.)

2.Do not connect a syrup source to the inlet circuit of the designated button (1-14 or A1-A2.) If circuit 1 through 14 is chosen leave the coldplate inlet circuit plugged with the red cap. If circuit A1 or A2 is chosen, plug the end of the inlet tube with a red cap from the coldplate, or with tape.

NOTE: The ambient circuits A1 and A2 do not give up a cold plate circuit.

© 2004-2007, IMI Cornelius Inc.

- 5 -

Publication Number: TP01070

Image 9
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Theory of Operation Product OverviewSyrup brands psi min Syrup bonus psi max System RequirementsProgramming Mode Flashing Sequences ProgrammingDispense Type 1, Carbonated water dispense Solid LED Valve with Flow Adjusters Setting Water Flow RateSetting a Button to Dispense Non-carbonated Water Only Adjusting Syrup/Water Ratio BrixSetting a Button to Dispense Carbonated Water Only Timed Dispense ProcedureDisassembly MechanicalControl Box Components Valve Removal Back Block Valve Service Carbonator TankMotor Removal System Plumbing Diagram Flavor Fusion -16 Brand Plumbing DiagramInterface Board and Harness PIN-OUT Detail Interface Board DetailFusion POINT-POINT Wiring DiagramWiring Ladder Schematic 115V- Flavor Fusion Ladder Type Wiring DiagramPCB TroubleshootingDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Condition Diagnostics Guide for the Main Control Board see FigureIMI Cornelius Inc