Cornelius TP01070 manual Diagnostics Guide for the Main Control Board see Figure, Condition

Page 23

FlavorFusion®/FlavorOverload Training Manual

DIAGNOSTICS GUIDE FOR THE MAIN CONTROL BOARD (SEE FIGURE 22)

State

Observed State

Sensor Input

Control Response

Service Remedy

 

of Red LED

 

 

 

 

 

 

 

 

0

Flash rate 3

Both probes read “wet”

Standby mode.

No service required

 

seconds

 

Pump = OFF

 

 

 

 

 

 

1

Flash rate

Pump is OFF and HIGH

Waiting for level to

No service required

 

1/2 second

probe reads “dry” and LOW

drop below LOW

 

 

 

probe reads “wet”

probe. Pump = OFF

 

 

 

 

 

 

2

Flash rate

Both HIGH and LOW

Normal mode.

No service required

 

1/2 second

probes read “dry”

Pump = ON

 

 

 

 

 

 

3

Flash rate

Entered when HIGH probe

Normal mode.

No service required

 

1/2 second

does not detect liquid, and

Pump = ON

 

 

 

LOW probe does detect

 

 

 

 

liquid, and pump is ON

 

 

 

 

 

 

 

4

Flash rate 1

Entered when HIGH probe

THIS IS AN ERROR

- Check electrical

 

second

reads “wet” and LOW probe

CONDITION.

connections at the

 

 

reads “dry”

 

carbonator tank, and at

 

 

 

 

connector J4 on the main

 

 

 

 

control board

 

 

 

 

- Black wire should be

 

 

 

 

connected to the LOW

 

 

 

 

probe and also to Pin 4 of

 

 

 

 

Connector J4

 

 

 

 

- Reverse the connections

 

 

 

 

if incorrect

 

 

 

 

- Replace harness if

 

 

 

 

necessary

 

 

 

 

 

5

ON

Poor signal connection to

Able to continue to

Check the harness

 

continuously,

the carbonator tank. May

function but

connections of the red

 

but “flickers”

result in short cycling of the

carbonator pump

signal wire at both ends:

 

every 3

carbonator pump.

short-cycles. Pump

1) at the carbonator ring

 

seconds

 

will come on each

terminal and

 

 

 

time a drink is drawn.

2) at Pin 5 of the J4

 

 

 

THIS SITUATION

connector at the main

 

 

 

SHOULD BE

control board

 

 

 

CORRECTED.

 

 

 

 

 

 

6

ON

Entered when pump has

THIS IS AN ERROR

Unplug the unit and plug it

 

continuously

run continuously for 5

CONDITION.

back in. This will reset the

 

 

minutes

 

unit's main control board

 

 

 

 

and restart the carbonator

 

 

 

 

pump.

 

 

 

 

 

LED

FIGURE 22

© 2004-2007, IMI Cornelius Inc.

- 19 -

Publication Number: TP01070

Image 23
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Theory of Operation Product OverviewSyrup brands psi min Syrup bonus psi max System RequirementsDispense Type 1, Carbonated water dispense Solid LED Programming Mode Flashing SequencesProgramming Valve with Flow Adjusters Setting Water Flow RateTimed Dispense Procedure Adjusting Syrup/Water Ratio BrixSetting a Button to Dispense Non-carbonated Water Only Setting a Button to Dispense Carbonated Water OnlyControl Box Components DisassemblyMechanical Valve Removal Back Block Motor Removal Valve ServiceCarbonator Tank System Plumbing Diagram Flavor Fusion -16 Brand Plumbing DiagramInterface Board and Harness PIN-OUT Detail Interface Board DetailFusion POINT-POINT Wiring DiagramWiring Ladder Schematic 115V- Flavor Fusion Ladder Type Wiring DiagramPCB TroubleshootingDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Condition Diagnostics Guide for the Main Control Board see FigureIMI Cornelius Inc