PROGRAMMING

NOTE: The programming mode is exactly the same for both brand and bonus keypads.

To enter the programming mode, press and hold the two program buttons (see FIGURE 3) at the top of the keypad for approximately 4 seconds. All keypad LEDs will flash off for approximately 1 second to indicate the start of the programming mode.

To exit programming mode, press and hold the two program buttons for approximately 4 seconds. All keypad LEDs will flash off for approximately 1 second, resuming normal operation mode.

Programming Mode Flashing Sequences

Once in programming mode, each dispense button LED flashes in a sequence cycle according to one (1) of six (6) dispense types. For Brand Keypads, only dispense types 1 and 2 should be used. For Bonus Flavor Keypads, dispense types 3 through 6 are used. The six (6) dispense types are described below, and shown in a timing diagram in FIGURE 1:

Dispense Type 1, Carbonated water dispense: Solid LED

Dispense Type 2, Non-carbonated dispense: Flashing LED 1.5 seconds ON, 1.5 seconds OFF

Dispense Type 3, 1-second flavor shot: LED flashes once for ¼ second, followed by 3 seconds

OFF

Dispense Type 4, 2-second flavor shot: LED flashes twice for ¼ second ON, ½ second OFF, followed by 3 seconds OFF

Dispense Type 5, 3-second flavor shot: LED flashes three (3) times for ¼ second ON, ½ second OFF, followed by 3 seconds OFF

Dispense Type 6, 4-second flavor shot: LED flashes four (4) times for ¼ second ON, ½ second OFF, followed by 3 seconds OFF

Start

Exit

proramming

programming

 

mode

mode

 

1. Carbonated water dispense

2.Non-carbonated dispense

3.1-second flavor shot

4.2-second flavor shot

5.3-second flavor shot

6.4-second flavor shot

0

1

2

3

4

5

Time (seconds)

FIGURE 1

NOTE: It is possible to program a flavor shot into a keypad. It is also possible to program a cove dispense (type 1 or 2) into a flavor shot keypad. Both instances result in an incorrect operation and should be corrected.

© 2004-2007, IMI Cornelius Inc.

- 3 -

Publication Number: TP01070

Image 7
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Theory of Operation Product OverviewSyrup brands psi min Syrup bonus psi max System RequirementsProgramming Programming Mode Flashing SequencesDispense Type 1, Carbonated water dispense Solid LED Valve with Flow Adjusters Setting Water Flow RateTimed Dispense Procedure Adjusting Syrup/Water Ratio BrixSetting a Button to Dispense Non-carbonated Water Only Setting a Button to Dispense Carbonated Water OnlyMechanical DisassemblyControl Box Components Valve Removal Back Block Carbonator Tank Valve ServiceMotor Removal System Plumbing Diagram Flavor Fusion -16 Brand Plumbing DiagramInterface Board and Harness PIN-OUT Detail Interface Board DetailFusion POINT-POINT Wiring DiagramWiring Ladder Schematic 115V- Flavor Fusion Ladder Type Wiring DiagramPCB TroubleshootingDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Condition Diagnostics Guide for the Main Control Board see FigureIMI Cornelius Inc