Power cord is

Carbonator pump motor is disabled.

Check the enable/disable switch on the

connected but

 

carbonator pump terminal box and

carbonator pump

 

enable it, if necessary.

does not run.

 

 

 

 

 

 

Probes were dry, unit was powered up,

This results in a 5 minute timeout.

 

water was not turned on, and

Unplugging the unit and plugging it in

 

carbonator did not fill.

will reset the unit and start the

 

 

carbonator pump.

 

 

 

 

Water service was interrupted for more

Unplugging the unit and plugging it in

 

than 5 minutes.

will reset the unit and start the

 

 

carbonator pump.

 

 

 

 

 

 

Carbonator pump is

Lower liquid level probe reads “dry”

Check color of leads going to probes.

short cycling with

while upper probe reads “wet”

Black should go to bottom probe and

every drink drawn

 

white to top probe. Reverse if incorrect.

 

 

 

 

 

 

Carbonator tank

A. Poor electrical connections between

A. Check connections at carbonator

overfills, overflows

carbonator tank and main control board

tank and at connector J4 on the main

through relief valve,

 

control board.

and pump shuts off

 

 

after 5 minutes.

 

 

 

 

 

 

B. Broken wires between carbonator

B. Replace wire harness

 

tank and main control board

 

 

 

 

 

C. Defective liquid level probes

C. Replace both liquid level probes

 

 

 

Publication Number: TP01070

- 18 -

© 2004-2007, IMI Cornelius Inc.

Image 22
Contents Flavorfusion Flavoroverload FLAVORFUSION/FLAVOROVERLOAD Training Manual Table of Contents Publication Number TP01070 2004-2007, IMI Cornelius Inc Product Overview Theory of OperationSystem Requirements Syrup brands psi min Syrup bonus psi maxProgramming Programming Mode Flashing SequencesDispense Type 1, Carbonated water dispense Solid LED Setting Water Flow Rate Valve with Flow AdjustersSetting a Button to Dispense Carbonated Water Only Adjusting Syrup/Water Ratio BrixSetting a Button to Dispense Non-carbonated Water Only Timed Dispense ProcedureMechanical DisassemblyControl Box Components Valve Removal Back Block Carbonator Tank Valve ServiceMotor Removal System Plumbing Diagram Plumbing Diagram Flavor Fusion -16 BrandInterface Board Detail Interface Board and Harness PIN-OUT DetailPOINT-POINT Wiring Diagram FusionLadder Type Wiring Diagram Wiring Ladder Schematic 115V- Flavor FusionTroubleshooting PCBDispenser Troubleshooting Symptom Cause Remedy 2004-2007, IMI Cornelius Inc Publication Number TP01070 Publication Number TP01070 2004-2007, IMI Cornelius Inc Diagnostics Guide for the Main Control Board see Figure ConditionIMI Cornelius Inc