Broan QP342BL, QP342SS Prepare Hood Location, Heat Sentry System, MAKE-UP AIR Damper, Fuses

Page 4

MODELS QP330BL • QP330SS • QP330WW QP336BL • QP336SS • QP336WW QP342BL • QP342SS • QP342WW

HEAT SENTRY SYSTEM

This range hood is equipped with an advanced Heat Sentry system that monitors excessive temperature and automatically adjusts the fan to the appropriate setting.

1)If the fan is on, the Heat Sentry system will increase the fan setting when the temperature is elevated. If the temperature con- tinues to rise, the Heat Sentry system will continue to increase the fan setting until the temperature is stabilized or reduced. The flashing light above the fan button shows the Heat Sentry system fan setting. Once the temperature has reduced, the Heat Sentry system will change the fan to the original setting.

2)If the fan is off, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. When the Heat Sentry system is on, the light above the high speed fan button will flash on and off. After the temperature has lowered to normal, the fan speed will be reduced until the temperature has stabilized, then the fan will turn off.

Page 4

MAKE-UP AIR DAMPER

The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately.

Make the connection to the Make-Up Air Damper with low volt- age wiring, as shown. See Make-Up Air Damper instructions for additional information.

BACK OF HOOD

LOW-VOLTAGE CONNECTOR

 

FOR MAKE-UP AIR DAMPER

 

RANGE

MAKE-UP AIR

HOOD

DAMPER

Note: Canadian version does not have this function.

FUSES

 

 

RANGE HOOD CONTROL BOARD

MAIN

LIGHT

FUSE

FUSE

LOW-VOLTAGE

WIRES

120

VAC

24

VAC

DAMPER

MOTOR

The Range Hood Control Board contains a Main Fuse and a Light Fuse to protect the controls from power surges. If a fuse has opened (blown), the green fan setting or light setting indicators will not operate properly when the fan or light buttons are pressed, and

REMOTE CONTROL

The hood is compatible with Broan RF Remote Control Model BCR1 (optional). Purchase separately.

PREPARE HOOD LOCATION

ROOF CAP

3¼" X 10" or

 

7" ROUND DUCT

 

(For vertical

 

discharge)

the fan and lights will not turn on.

New fuses can be purchased at your local electronic supply store. Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge- type fuses.

To replace a fuse:

1.Disconnect power at service entrance.

2.Remove filters and bottom pan.

3.Remove and inspect fuse. If it is not open (blown), additional diagnostics are needed.

SOFFIT

CABINET

HOOD

24" - 30" ABOVE

COOKING SURFACE

HOUSE WIRING (Top or Back of hood)

WALL CAP

3¼" X 10" DUCT

(For horizontal discharge)

1

Determine whether hood will discharge vertically (3¼”

 

x 10” or 7” Round), or horizontally (3¼” x 10” only). For

 

vertical or horizontal discharge, run ductwork between

 

the hood location and a roof cap or wall cap. For best

 

results, use a minimum number of transitions and elbows.

Image 4
Contents To Reduce the Risk of a Range TOP Grease Fire For Domestic Cooking onlyEvacuate and Call the Fire Department Cleaning & Maintenance ContentsOperation Minute Delay OFF TimerFeature Menu Clock SettingRemote Control Prepare Hood LocationHeat Sentry System MAKE-UP AIR DamperPrepare the Hood Vertical DuctingHorizontal Ducting IN. RoundNON-DUCTED Installation only For NON-DUCTED Installations Skip to Install the HoodDucted Installation only Damper Flap Pivot nearest the Top/Back Edge of HoodInstall Light Bulbs Install the Hood Connect the WiringRemove Electrical Wiring Box Cover from inside Service Parts WarrantyLamp Socket Bracket Light Screws Panel Remove 2 Light Panel Screws and Light Panel. SetPour Usage Domestique Seulement Avertissement Avertissement RemarquePour hottes sans conduit de 76 cm 30 po de largeur Modèle BPPF36 ou un ensemble de 3 filtres pourFonctionnement ContenuNettoyage ET Entretien Arrêt Différé DE 10 Minutes MinuterieRéglage DE L’HEURE Menu DE FonctionsConnecteur Basse Tension Pour Arrière DE LA HotteClapet D’AIR DE Compensation Préparation DE LA Hotte Fente VISPlaque NON CanaliséeInstallation DE LA Hotte Installation DesampoulesRaccord DU Câblage VIS DE Mise À LA Terre Câble Électriqe DE LA MaisonPièces DE Rechange GarantieSupport DU Socle D’AMPOULE Panneau ’ÉCLAIRAGE VISPrecaución Solamente Para Cocinar EN Casa Advertencia AdvertenciaNota Contenidofuncionamiento Limpiezay MantenimientoNota LUZ 3 interruptores de botones y 4 ajustes de lucesApagado CON Retardo DE 10 Minutos TemporizadorMenú DE Funciones Ajustes DEL RelojNota la versión canadiense no tiene esta función Sistema Heat SentryFusibles Regulador DE Aire DE RepuestoPrepare LA Campana 11 Únicamente EN Instalaciones SIN Conductos Únicamente EN Instalaciones SIN Conductos10 Únicamente EN Instalaciones SIN Conductos 13 Únicamente EN Instalaciones CON ConductosInstale LA Campana Conecte EL CableadoInstale LAS Bombillas 17 Únicamente EN Instalaciones CON ConductosPiezas DE Servicio GarantíaSoporte DEL Receptáculo DE LA Lámpara Panel DE Iluminación Tornillos