PREPARE THE HOOD

Note: Carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flue, prior to final installation.

1.To avoid demage while forwarding the applicance has been locked by means of four screws to a laminboard panel on the bottom of the packing.

To separate the hood from the panel:

a.Disassemble the central block: rotate the block outside softly (Fig. 4).

b.Remove the 4 screws (Fig. 5).

2.Fit the 2 brackets on the central block in such a way that the two slots are plugged. Each bracket must be fixed with (2) 3.9 x 6 mm mounting screws (Fig. 6).

3.Attach the discharge collar onto the hood (Fig. 7); it must be attached by means of 4 mounting screws (3,9x9,5 mm Pan Head).

4.Remove the tape located on the damper (Fig. 7).

5.Attach an adequate length of 8” round steel ducting to the range hood discharge collar (Fig. 8).

Duct tape all joints to make them secure and air tight.

6.If the ductwork is placed on the wall (and not on the ceiling), read the following instructions:

- disassemble the motor block (included the plate where it is fixed) unscrewing the 4 screws (Fig. 9).

- rotate motor block in order to have the duct connector toward the wall.

MOUNTING SCREWS

(3.9x6mm)

BRACKETS

FIG. 6

CENTRAL BLOCK

FIG. 4

FIG. 5

REMOVE THE TAPE

DISCHARGE COLLAR

FIG. 7

- 12 -

Image 12
Contents Model WM24E Read and Save These Instructions Intended for Domestic Cooking only ! WarningPage Maintenance Hood CleaningGrease Filters Operation ControlsFuse Replacement Halogen BulbsEration on the appliance Prepare the Hood Install the Ductwork Exterior or IN-LINE Blower SelectionIN-LINE Blower Wiring Exterior or In-line blower connectionPower connection at hood Remove the wiring box coverRemove the 4 screws Fig Mounting screws 3.9x9.5mm Black Install the Hood Warranty Broan ONE Year Limited WarrantyLisez ET Conservez CES Instructions Seulement Pour Utilisation Domestique AvertissementsPage Entretien Filtres anti-graisseNettoyage de votre hotte Commandes FonctionnementRemplacement Fusible Ampoules Halogenes’appareil Preparez LA Hotte Ventilateur Externe Ventilateur IN-LINE Installation Electrique Branchement du ventilateur externe ou «in-Line»Branchement du courant à la hotte LINE-INPréparation DE LA Hotte Diamètre DU Conduit Collier ’EVACUATION Installation DE LA Hotte PlafondGarantie Garantie Broan Limitée À UN ANLEA Y Conserve Estas Instrucciones AdvertenciaAdvertencia Mantenimiento Filtros antigrasaLimpieza de la campana Funcionamiento MandosLamparas Halogenas Sustitucion FusibleAtención las lámparas pueden estar calientes Prepare LA Campana Decorativo Tornillos DESelección DEL Ventilador Exterior O DEL Ventilador IN-LINE Instalacion DEL Tubo DE ExtraccionVentilador IN-LINE Instalación Eléctrica Blanco, el rojo con el negro y el verdeConexión del ventilador exterior o In- Line Conexión de la corriente a la campana CON.DE Energia a LA CampanaPreparación DE LA Campana Conducto DE 8 DE Diámetro Casquillo Tornillos DE Montaje Instalación DE LA Campana TechosGarantia Garantia Broan POR UN AÑOService Parts Model WM24EListe Pieces DE Rechange Modele WM24ELista DE Piezas DE Recambio Modelo WM24EModel WM24E 04307489/4N