Best WM24E manual Exterior or IN-LINE Blower Selection, Install the Ductwork

Page 8

EXTERIOR OR IN-LINE BLOWER SELECTION

CAUTION: Either an exterior blower or in-line blower may be used with this hood. The WM24E hood must be installed with blower models EB6, EB9, EB12, EB15, ILB3, ILB6, ILB9, or ILB11 only. Other Blowers cannot be substituted (Blowers sold separately).

The blower must be UL listed for Canadian and U.S. use, and evaluated for use with solid state speed control, rated 120V, 60 Hz, 6.0 A max.

INSTALL THE DUCTWORK

EXTERIOR BLOWER

NOTE: To reduce the risk of fire, use only metal ductwork.

1.Choose the location where the Exterior or In-Line Blower will be mounted. See illustrations below for mounting location suggestions and restrictions.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with long duct runs.

4.After the Exterior or In-Line Blower has been installed, connect round metal ductwork and work back towards the hood location. Use duct tape to seal joints between ductwork sections.

5.An 8” round to 10” round transition (Model 414) is required. For best air performance, install the transition as close to the range hood as possible.

DUCTWORK ON THE CEILING

10” ROUND

EXTERIOR

DUCT

BLOWER

 

 

8” TO 10”

 

ROUND

 

TRANSITION

8” ROUND

DUCT

4-3/4”

HOOD

8-1/8”

SUGGESTED MOUNTING LOCATIONS

OK

OK

CAUTION: MAY NOT FIT

UNDER EAVES OF SINGLE

STORY HOMES

DUCTWORK ON THE WALL

8” TO 10”

ROUND

TRANSITION

8-5/16”

EXTERIOR

BLOWER

10”

HOODROUND DUCT

23-3/8” TO 30” ABOVE

1-1/4”

COOKING SURFACE

 

23-3/8” TO 30” ABOVE COOKING SURFACE

- 8 -

Image 8
Contents Model WM24E Read and Save These Instructions Intended for Domestic Cooking only ! WarningPage Grease Filters MaintenanceHood Cleaning Operation ControlsEration on the appliance Fuse ReplacementHalogen Bulbs Prepare the Hood Install the Ductwork Exterior or IN-LINE Blower SelectionIN-LINE Blower Wiring Exterior or In-line blower connectionPower connection at hood Remove the wiring box coverRemove the 4 screws Fig Mounting screws 3.9x9.5mm Black Install the Hood Warranty Broan ONE Year Limited WarrantyLisez ET Conservez CES Instructions Seulement Pour Utilisation Domestique AvertissementsPage Nettoyage de votre hotte EntretienFiltres anti-graisse Commandes Fonctionnement’appareil Remplacement FusibleAmpoules Halogenes Preparez LA Hotte Ventilateur Externe Ventilateur IN-LINE Installation Electrique Branchement du ventilateur externe ou «in-Line»Branchement du courant à la hotte LINE-INPréparation DE LA Hotte Diamètre DU Conduit Collier ’EVACUATION Installation DE LA Hotte PlafondGarantie Garantie Broan Limitée À UN ANLEA Y Conserve Estas Instrucciones AdvertenciaAdvertencia Limpieza de la campana MantenimientoFiltros antigrasa Funcionamiento MandosAtención las lámparas pueden estar calientes Lamparas HalogenasSustitucion Fusible Prepare LA Campana Decorativo Tornillos DESelección DEL Ventilador Exterior O DEL Ventilador IN-LINE Instalacion DEL Tubo DE ExtraccionVentilador IN-LINE Conexión del ventilador exterior o In- Line Instalación EléctricaBlanco, el rojo con el negro y el verde Conexión de la corriente a la campana CON.DE Energia a LA CampanaPreparación DE LA Campana Conducto DE 8 DE Diámetro Casquillo Tornillos DE Montaje Instalación DE LA Campana TechosGarantia Garantia Broan POR UN AÑOService Parts Model WM24EListe Pieces DE Rechange Modele WM24ELista DE Piezas DE Recambio Modelo WM24EModel WM24E 04307489/4N