HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1)If blower is OFF - it turns blower ON to HIGH speed.
2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.
HALOGEN BULBS
This range hood requires four halogen bulbs (Type T3, 12Volt, 20Watt Max,
WARNING: Always switch off the elec- trical supply before carrying out any op-
eration on the appliance.
To change bulbs:
1.Open the cover by prying from the proper slots.
2.Remove the bulb by pulling sideways. (DO
NOT ROTATE).
! CAUTION: Bulb may be hot.
3.Replace with Type T3, 12Volt, 20 Watt Max,
! CAUTION: Use of bulbs greater than 20 watts will cause the fuse to open.
FUSE REPLACEMENT
FUSE
IF LIGHTS FAIL TO OPERATE, DISCON-
NECT POWER AT THE SERVICE EN-
TRANCE. CHECK THE FUSE AND RE-
PLACE IF NECESSARY.
1.Remove the grease filters.
2.Unscrew the cap from the fuse holder and remove the fuse.
3.Replace the fuse with the same size and amperage (5 x 20mm, 4 amp, 125 volt).
! CAUTION: Use a fuse greater than 4 amps may damage the transformer.
4.Reinstall the fuse holder cap.
5.Reconnect power at the service entrance.
-6 -