INSTALLATION

1.3

ASSEMBLING TWO APPLIANCES

The appliance is designed for connection to fixed lines. The appliances are suitable for setting up as single appliances or as a group of appliances. They can be set up freely in the room, side by side, at the side and/or at the back against a wall.

Gaps between two appliances or appliance and sidewall should be filled with a FDA approved silicone such as Samco RTV103.

1.1DISTANCES

If an appliance is set up next to or against temperature-sensi- tive furniture or similar, a safety gap of approximately 6“ (150

mm)should be maintained or some form of heat insulation fit-

ted.

The walls must be made up of non-combustible material like tiles or steel.

1.2HEIGHT ADJUSTMENT

Appliance on feet: Alignment is carried out by screwing the lower foot parts in or out.

Appliance on

Irregularities or differences in height can

steel plinth:

be equalized by inserting one or several

 

strips of chrome nickel steel.

Appliance on feet.

DTurn the lower part of the feed to adjust the appliance high.

The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high of 8“ (200 mm) can be recommended and results in an appli- ance high of 35,4“ (900 mm).

Note:

Adjustment of the legs shall provide an unobstructed clearance of minimal 6“ (150 mm) and maximal 8“ (200

mm)beneath the unit due to sanitary and stability aspects.

(1)

a

(1)

(2)

b

The lower part of the foot must not be unscrewed too far. The exposure of threads is prohibited.

c

Fig.1 Lateral connection

The assembly kit contains two of each of the following:

caged nuts (1 / Fig.1) pre-assembled on the right-hand side of the appliance, hexagonal screws M8x25 (1 / Fig.1) and moun- ting links (2 / Fig.1).

DRemove the control panels from both appliances as in 2.2

DRemove the front panels from both appliances as in 2.1

DKeeping the screw (1 / Fig.1) loose, turn it until it is approxi- mately 5 mm deep in the caged nut.

Positioning the appliances:

DPlace the appliances next to one other.

DAlign for position and height.

Connect the appliances:

DFit the mounting link (2 / Fig.1) into the inside of the second appliance's left connecting plate.

DTighten the screws.

Note

If required, the caged nuts can also be fitted on the other side of the appliance.

62.9540.01_UL

Page 5

Image 9
Contents GAS Cookers Fourneaux Pour GAZ Thermaline S90Connections Raccordement Installation Drawings Plans DinstallationFree standing isolé Connections Raccordement III Installation InstructionsTGENERAL Information Operating Instructions62.9540.01UL Safety Instructions and Instructions for USE General InformationGeneral Information Specification Plate Technical DataGAS Consumption PackagingII . Installation Instructions Installation InstructionsInstallation Access to Interior Sidewall D Assembling on CastorsSteel Plinth Front Panels a and B DownpipeControl Panael C OVEN, Storage SPACE, HOT CabinetConnection Installation Instructions GAS ConnectionGAS Pressure Gas pressure tolerancesIII . Operating Instructions CleaningOperating Instructions Open GAS BurnersOpen Compartment FaultsFinned PAN Rests BurnerTemperature Setting Switching onSwitching OFF Cleaning Doors and InteriorGuide Temperatures for Baking C Guide Temperatures for Roasting CBurner Chamber Pilot BurnerInstructions Générales Instructions GénéralesConsignes DE Sécurité ET Dutilisation Données Techniques Plaque SignalétiqueConsommation DE GAZ EmballageInstructions Relatives À Linstallation II . Instructions Relatives À LinstallationMise EN Place Assemblage DE Deux AppareilsAccès À Lintérieur Paroi Laterale D Assemblage SUR RoulettesSocle EN Acier Panneau DE Commande C SortiePanneau Avant a et B Instructions Instructions Relatives À Linstallation Raccordement AU GAZRaccordement Pression DE GAZIII . Instructions DE Fonctionnement Instructions DE FonctionnementZones DE Cuisson Ouverte À GAZ Nettoyage Espace DE Rangement ProblèmesProblèmes Cause Remède Brûleur principal Chauffage ET Réglage Première Mise EN Service / Nouvelle Mise EN ServiceAllumage 2 Réglage DE LA Température3 Brûleur Principal Chambre DE CombustionDispositif Dallumage Règles DE TravailInstructions DE Fonctionnement Mbar Mbar