GE J2B915 Support Troubleshooting, Tips, Connect the Range to the Gas Supply

Page 44

Safety Instructions

Installation of the range.

Read these instructions completely and carefully.

Connect the Range to the Gas Supply

Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hookup has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Installation Instructions Operating Instructions

Because hard piping restricts movement of the range, the use of a CSA International-certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection.

Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.

Install a manual gas line shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.

Install male 1/2″ flare union adapter to the 1/2″ NPT internal thread elbow at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.

When installing the range from the front, remove the 90° elbow for easier installation.

Install male 1/2″ or 3/4″ flare union adapter to the NPT internal thread of the

manual shut-off valve, taking care to backup the shut-off valve to keep it from turning.

Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.

When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.

CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.

When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.

*Teflon: Registered trademark of DuPont

Flexible Connector Hookup

Rigid Pipe Hookup Options

Gas Flow into Range

45° Elbow

Tips

Pressure regulator

90° Elbow

Support Troubleshooting

Installer: Inform the consumer of the location of the gas shut-off valve.

Adapter

1/2or 3/4Gas pipe

Gas Flow into Range

Flex connector (6 ft. max.)

Adapter

Gas shut-off valve

Nipple

Pressure

regulator

Union

Installer: Inform the consumer of the location of the gas shut-off valve.

Alternate Hookup

90° Elbow

Nipple

Black iron pipe

Union

Nipple

Gas shut-off valve

1/2or 3/4Gas pipe

Adapter

90° Elbow

Nipple

Quick connect or union

Gas

Nipple

Pressure regulator

shut-off valve

1/2or 3/4

 

Gas pipe

90° Elbow

90° Elbow

Consumer

44

Installer: Inform the consumer of the

Adapter

 

location of the gas shut-off valve.

Gas Flow into Range

 

 

Image 44
Contents Installation Instructions Write the model and serial numbers here Model # Serial #Install ANTI-TIP Devices Packed with Range ANTI-TIP DeviceAll ranges can tip and injury could result Important Safety Notice Safety PrecautionsSafety Safety Instructions Surface BurnersElectric Warming Drawer SELF-CLEANING Oven Instructions Safety InstructionsSupport Troubleshooting Tips Cook Meat and Poultry THOROUGHLY…Using the gas surface burners Instructions InstallationInstructions Operating Before Lighting a Gas BurnerCase of Power Failure Top-of-Range CookwareUsing the oven controls Installation Instructions Operating Using the ovenInstructions Safety Troubleshooting Tips InstructionsHow to Set the Oven for Broiling-Close the oven door Broiling GuideBroiling Guide HI BroilUsing the clock and timer Using the timed baking and roasting features How to Set an Immediate Start and Automatic StopHow to Set a Delayed Start and Automatic Stop Instructions Operating InstructionsUsing the probe. on some models Troubleshooting Tips Consumer SupportHow to Set the Oven For Roasting When Using the Probe Installation InstructionsUsing the convection oven Convection BakeConvection Roast Adapting Recipes…Multi-Shelf Baking Troubleshooting Tips Consumer SupportHow to Set the Oven for Convection Baking or Roasting Touch the Convection Roast pad Convection Roasting Guide-Suggested Settings Meats Minutes/Lb Oven TempTouch the Convection Bake pad Using the timed convection baking featuresConsumer Support Troubleshooting Tips Installation Special features of your oven control Safety InstructionsFahrenheit or Celsius Temperature Selection Hour Shut-OffControl Lockout on some models Hour, 24 Hour or Clock Black-OutCook and Hold Your control is set to use a 12 hour clockOperating Instructions Using the Sabbath Feature. on some modelsInstructions Troubleshooting Tips Adjust the oven thermostat-Do it yourself Installation Instructions Operating InstructionsTo Adjust the Thermostat Type of margarine will affect baking performanceUsing the electric warming drawer When Using the Warming DrawerOn Signal Light Control KnobTemperature Selection Chart To Warm Serving Bowls and PlatesHow to Set the Oven for Cleaning Using the self-cleaning ovenBefore a Clean Cycle After a Clean Cycle Operating Instructions SafetyHow to Delay the Start of Cleaning Care and cleaning of the range Sealed Burner AssembliesAfter cleaning ReplacementBurner Caps and Heads Burner capsInstallation Instructions Broiler Pan and Grid Lift-Off Oven DoorOven Heating Elements Safety Instructions Operating Warming Drawer PanRemovable Warming Drawer on some models To remove the warming drawerLock out the touch pads before cleaning Unlock the touch pads after cleaningOven Air Vents Upper Control PanelOven Light Replacement Oven ShelvesTo remove Do not remove any screws to remove the coverInstallation of the range For Your SafetyCommonwealth of Massachusetts Before YOU BeginMust Never be Less than 24 Inches Dimensions and Clearances Consumer SupportTroubleshooting Tips Operating Instructions InstallationTools YOU will Need Gas line shut-off valveConsumer Support Troubleshooting Gas Supply RequirementsProvide Adequate Gas Supply Recommended Gas Pipe Outlet LocationsRecommended Electrical Outlet Locations Electrical Power Supply RequirementsProvide Proper Electrical Supply Support Troubleshooting Flexible Connector Hookup Rigid Pipe Hookup OptionsTips Connect the Range to the Gas SupplyInstallation Instructions Troubleshooting Tips Consumer SupportUsing an Existing Nema 14-50R Receptacle Operating Instructions Replace the Power Cord OptionalWire Power Cord Installation Option Wire Conduit Installation Option Safety InstructionsWire used, location and enclosure Installation Instructions Operating Instructions SafetyReplace the Wire Cover Seal the Openings Assemble Surface BurnersCheck Ignition of Surface Burners Electric IgnitionInstructions Operating Instructions Safety Instructions Quality of FlamesLevel the Range Yellow flamesSafety Instructions Operating Instructions Install the Anti-Tip DeviceWhen All Hookups Are Completed Performed by a qualified LP gas installerBefore you call for service… Problem Possible Causes What To DoSee the Installation of the range section Oven temperatureSee the Adjust the oven thermostat-Do it yourself Clock and timerOven not clean after Clean cycleIs on when you want Power outageFan noise Convection fanNot working Drawer does not slideAccessories Looking For Something More?We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Dual Fuel Range Warranty Safety Instructions OperatingGE Will Replace What GE Will Not CoverSchedule Service Parts and AccessoriesConsumer Support GE Appliances Website Real Life Design Studio

J2B915 specifications

The GE J2B915 is an advanced gas turbine engine that represents a significant milestone in aerospace technology, primarily designed for use in regional and business aircraft. Engineered by General Electric, the J2B915 combines innovative design features with state-of-the-art technologies to provide high performance, reliability, and efficiency.

At the heart of the J2B915 is its powerful core, which is designed to operate at high temperatures and pressures. This capability allows the engine to deliver substantial thrust while maintaining a relatively low fuel consumption rate. The engine achieves this efficiency through its advanced compressor and turbine design. The axial-flow compressor, known for its ability to compress air efficiently, contributes to the overall performance of the engine, while the high-pressure turbine extracts energy effectively to drive the compressor.

One of the standout features of the J2B915 is its noise reduction technology. In an era where environmental regulations are becoming increasingly stringent, the engine's design incorporates features aimed at minimizing noise footprint during operation. This is achieved through the use of advanced acoustic materials and innovative turbine blade designs, which work together to reduce noise levels while ensuring optimal performance.

Another key characteristic of the J2B915 is its modular design, which enhances maintainability and serviceability. This modularity allows for easier access to engine components, simplifying routine inspections and repairs. The design philosophy also translates to a reduction in downtime, which is critical for commercial operators seeking to maximize aircraft availability.

The GE J2B915 also boasts impressive durability and reliability. Engineered with advanced materials and coatings, it is capable of withstanding the rigors of continuous operation in various environments. The engine’s reliability is bolstered by GE’s rigorous testing protocols and quality assurance processes, ensuring that it meets the high standards expected by operators worldwide.

In terms of controls and monitoring, the J2B915 utilizes an advanced digital engine control system. This system monitors various performance parameters in real-time, allowing for precise management of engine functions and enhancing operational efficiency. The digital technology also supports predictive maintenance, alerting operators to potential issues before they escalate into more significant problems.

In conclusion, the GE J2B915 gas turbine engine embodies a blend of cutting-edge technologies, robust design, and a commitment to performance. Its high efficiency, low noise output, and reliable operation make it a preferred choice for regional and business aviation markets, cementing its reputation in the competitive landscape of aerospace propulsion systems.