Safety Instructions
Installation of the range.
Connect the Range to the Electrical Supply
Skip to Step 5 if the power cord shipped on the range does not match your wall receptacle.
Using an Existing NEMA 14-50R Receptacle
Operating Instructions
■Plug the range power cord into a properly grounded wall receptacle. Skip to Step 6 if the range power cord matches the wall receptacle.
NOTE: Your range is shipped with a
Effective January 1, 1996, the National Electric Code requires that new construction (not existing) utilize a
A range cord rated at 40 amps with 125/250 minimum volt range is required. A
NOTE: A
Instructions
Replace the Power Cord (Optional)
Perform this step only if the power cord shipped on the range does not match your wall receptacle.
Remove the wire cover (on the back of | Loosen the strain relief screws and |
the range) by removing two (2) screws | remove the power cord. |
using a 1/4” nut driver. |
|
Do not discard these screws.
Consumer Support Troubleshooting Tips Installation
2 screws to remove wire cover
Retaining tab
Back of range
Wire cover
Remove the 3 lower power cord terminal screws from the terminal block and the ground screw and plate.
Terminal | Neutral | |
block | ||
terminal | ||
|
Ground plate |
(grounding to |
range) |
Ground screw
NOTE: The replacement power cord must be a
or conduit. Cords may be provided with ring terminals on wire and a strain relief device.
Follow the
46 | Place the terminal screws and ground |
screw in safe location for later use. |