Amana ART6114*, ART6113* owner manual Installing 4-Wire Power Cord

Page 8

Installing 4-Wire Power Cord

!WARNING

To avoid the risk of severe electrical shock or death, ground wire must be attached to frame of range, using ground screw provided. Ground wire must not contact any other terminal.

1.Remove rear wire cover on back of range.

2.Place strain relief (winged clamp) in cord access hole below terminal block.

Strain relief is supplied with cord. Place wings through hole entering from bottom.

Screw holes in clamp should be below mounting panel.

3.Remove green ground screw (retain for use in step 8) and unscrew brass nut on center terminal. Remove grounding strap.

Wires from range

(Number of wires on each terminal can vary)

Center terminal nut

Grounding

strap

Green ground screw

Remove Green Ground Screw

4.Place cord through strain relief.

5.Attach cord neutral (center) or white wire to center terminal on terminal block. Secure with hex nuts provided. See “Attach 4-wire Power Cord” illustration.

6.Attach power lead, red wire or black wire to left terminal. Secure with hex nuts provided.

7.Attach power lead, red wire or black wire to right terminal. Secure with hex nuts provided.

Wires from range

(Number of wires on each terminal can vary)

 

A

 

 

 

 

 

B

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wires from power cord

A—Power lead terminal (Connect black or red insulated wire and secure with brass nut.)

B—Neutral terminal (Connect insulated white insulated wire and secure with brass nut.)

Attach 4-wire Power Cord

8.Position grounding strap down and away from terminal block. Attach green or bare wire and grounding strap to back of range using green ground screw previously removed in step 3.

Wires from range

(Number of wires on each terminal can vary)

A

Wires from power cord

A—Ground screw (Connect green insulated wire and secure with screw.)

Position Grounding Strap

9.Firmly tighten all connections to ensure proper electrical connection.

10.Place screw through strain relief, tighten, and replace rear wire cover.

8

Image 8
Contents Please Read Manual Before Operating Range Installer CustomerContents Important Safety Information Precautions Case of FireSurface Element Fire Oven FiresInstallation Packing MaterialRange Location Cabinet OpeningPower Supply Location Power Cord RequirementsIrregular Cabinet and Countertop Heights Line Voltage RequirementsInstalling 3-Wire Power Cord Neutral terminal connect wirePower terminals Ground strapInstalling 4-Wire Power Cord Converting 3-Wire to 4-Wire Power Cord Anti-tip Bracket InstallationRemoval and Replacement of Range Level RangeRange Features OperationCooking with Surface Elements Surface Element SettingsPreparing to Cook with Smoothtop Elements Some Models Type Temperature Uses UtensilsOven Signals Description Electronic Oven ControlPads and Knobs Description Panel Lights DescriptionOven Switches Description Other FeaturesPrepare to Bake Setting Electronic ClockSetting Electronic Timer Baking Oven Rack PlacementBake Pan Placement Self-clean Prepare for Self-cleanBroiling Broiling TipsAfter Self-cleaning Cycle Self-cleaningInterrupt Self-Clean Cycle Food Oven Temperature Cooking Time Cooking GuideBaking Guide Poultry Roasting GuideFood Thickness Rack position Cooking time Beef and Pork Roasting GuideBroiling Guide Care and Cleaning Removing Oven Door Replacing Oven LightRemoving Storage Drawer Some Models Removing Panel Some ModelsCleaning Part Materials to Use General DirectionsCleaning Smoothtop Rangetop Problem Cause To Prevent To RemoveBefore Calling for Service Problem CheckWarranty Cooking Products excluding wall ovensPage Page Quick Reference Instructions