WARNING
FILLING THE LP GAS CYLINDER:
•Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.
•New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
•DO NOT allow the cylinder to be filled beyond 80% capacity.
•Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve, other types of caps or plugs may result in leakage of propane.
•If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an
INSTALLING THE LP GAS CYLINDER ONTO THE GRILL:
1.Check that the cylinder valve is closed by turning the knob clockwise.
2.Open the right side door of your grill cabinet. Place the cylinder into the tank holder in the bottom of cabinet.
3.Orient the cylinder such that the valve opening faces the side burner, and so that the hose is not kinked or damaged.
4.Fully tighten the tank retention screw on the back side of grill to secure tank.
5.Attach or detach regulator to the LP gas cylinder only when cylinder is at rest in tank holder.
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
1.The system will not allow gas flow from the cylinder until a positive connection to the valve has been made.
Note: The cylinder valve must be turned off before any connection is made or removed.
2.A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F to 300°F (115°C to 150°C). If this should happen, remove the entire regulator assembly and dispose of properly. A replacement regulator assembly can be purchased by contacting customer service at
3.A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour. If the flow limiting device is activated, perform Regulator Resetting Procedure.
Tank Retention Screw
REGULATOR RESETTING PROCEDURE:
1.Make sure that all burners are off. The red indicator light above the ON/OFF switch for the burners should not be lit, turn off the cylinder valve and disconnect regulator from LP gas tank. Wait approximately two minutes.
2.Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset.
6