VIDEO SURVEILLANCE

To use the GXV300x as a video surveillance camera, please configure the GXV300x and the monitor PC in the same LAN environment. Advanced users may manipulate it to work over WAN (configuration not rec- ommended and not covered in this User Manual). For best results, Grandstream recommends using this feature in the same LAN environment or ensure both monitor PC and phone have static public IP ad- dress.

VIDEO SURVEILLANCE CONFIGURATION DIRECTIONS

Phone side: In the ADVANCED SETTING page, find the following field and change the default setting

from “NO” to “YES”: reboot the device.

PC side (Monitor Device):

1.Download VLC from http://www.videolan.org/vlc/ . This is the only free open source player that supports both the Grandstream device and RFC 3984.

2.Launch VLC.

3.Go to Tools -> Preferences -> Show Settings “All” (in the bottom of the page) -> Input/Codecs - >Demuxers -> H264. Change “Frames per Second” value to 5 and then save.

4.Go to Tools -> Preferences -> Show Settings “All” (in the bottom of the page) -> Input/Codecs -> Access modules -> Real RTSP. Check “Advanced Options” in the bottom. The option will show. Change “Caching value (ms)” value to 1000 and then save. You may change it to a smaller value to reduce the delay.

5.Close the Preferences window and go to File ->Open Network Stream:

Select RTSP as the protocol

Enter the URL in the “Customize” field using the f ormat:

rtsp://admin:ADMIN_PASSWORD@DEVICE_IP_ADDRESS:DEVICE_RTSP_PORT.

Change the text in red to your own configuration parameter:

i.ADMIN_PASSWORD is the phone’s administrator password for WebUI.

ii.DEVICE_IP_ADDRESS is the phone’s IP.

iii.DEVICE_RTSP_PORT is the RTSP port setting of the device. If the phone is us- ing default value 554, omit the port portion from the URL

Click OK or enter Return key. Start viewing the video surveillance from the PC.

Limitations:

1.Video surveillance supports only two (2) concurrent viewers on the GXV. The video stream is set at 5 frame per second and 128kbps.

2.The video stream will stop if a call starts. The video stream server (the phone) will not actively terminate the session. Most clients (the VLC software in PC) will terminate the session after cer- tain interval of time. A restart of the VLC software is required to view the surveillance again.

Grandstream Networks, Inc.

GXV300x User Manual

Page 51 of 54

 

Firmware 1.2.3.7

Updated: 12/2010

Image 53
Contents Grandstream Networks, Inc Table of Contents GXV300X WEB GUI Welcome Installation 10/100Mbps RJ-45 port for uplink to Ethernet 10/100Mbps RJ-45 port for connecting PC as switch modeTab with exten Sion down Handset Rest TabSion up Open Standards Compatible Feature RichNetwork Interfaces Superb Audio QualityVideo Features Feature KeysAudio Features Call Handling FeaturesFeatures Firmware UpgradesCaller ID Privacy Advanced ServerUsing GXV300X IP Video Phone OSD/Camera Loopback Dis- play On/Off key Play and OSD ON/OFF UP ↑Completing Calls Handset, Speakerphone and Headset ModeMaking Calls using IP Addresses For example Quick IP Call ModeCall Waiting/ Call Hold Receiving CallsCall Transfer Way ConferencingMute/Delete Voice Messages Message Waiting IndicatorDo Not Disturb Camera BlockOSD Display Explanation Camera Local Loopback Display and OSD ON/OFFMaking/Receiving Calls via Pstn only applicable on GXV3005 Making callsEnable Call Waiting for all subsequent calls Disable Call Waiting for all subsequent callsDisable Call Waiting per Call Enable Call Waiting per CallConfiguration Guide Flow Chart of KEY PAD Configuration Menu ∙ Factory Reset ∙ Audio ∙ Video Codecs ∙ Upgrade∙ Ring Volume Phone Book Call History∙ Pstn Loopback ∙ Ethernet Loopback Access the Web Configuration PagesDefinitions Port End User Password Sensitive with a maximum length of 25 charactersDaylight Savings Time Time ZoneRule Syntax 7,2,011,1,7,2,060Advanced User Configuration G723 rate Admin PasswordSilence SuppressionPassword Mode Enable VideoTimeout Video FrameConfig File ConfigUpgrade Use Random PortConf File AuthenticateScreen Saver DownloadCall-Waiting Disable DisableCall-Waiting Tone Disable UpdateAuthenticate Password Authenticate IDUnregister on Reboot Account ActiveNAT Traversal Stun Keep-Alive Using SIP OPSubscribe for MWI Proxy-RequireCaller Request Timer Enable Call FeaturesDial Plan Dial Plan Rules 1900x. =16172-9xxxxxx 12-9xx2-9xxxxxx 0112-9xForce Timer Callee Request TimerEnable 100rel UAC Specify RefresherDefault Resolution Jitter DelayEnable RFC5168 Support Srtp ModeAC Termination Imped Silence TimeoutAnce Caller ID SchemeDisable FXS Caller ID Volume AmplificationEnable FXS Call Waiting Caller IDConfiguration Through Secure Central Provisioning Server No Local HTTP/TFTP Server Web Configuration InterfaceKey Pad Menu Instructions for firmware upgrade via a Local Tftp Server Managing Firmware and Configuration File Download Introduction How It Works and ConfigurationExample Phonebook File XML SyntaxScreensaver Images Screenshot of Screensaver Utility Ringtone File Size USB 2.0 Port Connect the GXV300X to Your TV using RCA CableCross Over Cable For Some Model of Headset Headset Jack DiagramCross Over Cable required for Plantronics Headset Limitations PC side Monitor DeviceScreenshot Monitoring Station Grandstream Networks, Inc Restore Factory Default Setting