Vanguard Heating SBVBP(C) INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2, Owner’S Manual, Continued

Page 15
INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Gas Valve

Equipment

Propane/

LP Supply

Shutoff

Tank

Valve

 

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 34. If wires are not connected as shown, the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner sys- tem to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

Figure 32 - Checking Gas Joints for Propane/LP Gas Burner System

Equipment

Shutoff

Valve

Gas Meter

Gas Valve

Figure 33 - Checking Gas Joints for Natural Gas Burner System

To Control

Switch or

Optional

Accessory

Figure 34 - Control Valve Terminals

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

Manual background WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Open lower door panel. The valve is attached to the underside of the burner system assembly.

2.Disconnect from the valve the wires running from the ON/OFF switch.

Continued

106828

15

For more information, visit www.desatech.com

Image 15
Contents Do not try to light any appliance Do not touch any electrical switch OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GASDANGER Carbon monoxide poisoning may lead to death SAFETY INFORMATIONSBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEM WARNINGSLOCAL CODES PRODUCT FEATURESOWNER’S MANUAL PRODUCT IDENTIFICATIONPRE-INSTALLATION PREPARATION LOCATION AND SPACE REQUIREMENTSetc. in the air exist, may discolor walls STOVE BODY ASSEMBLY CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLYContinued INSTALLING OPTIONAL BLOWER ACCESSORY INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODYINSTALLING REAR COVER CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLYVENTING INSTALLATIONINSTALLATION PRECAUTIONS TYPE B-VENT INSTALLATION Listed B-0 or GreaterCHECKING VENT CAPACITY VENTING INSTALLATIONINSTALLATION OF LISTED B-1 VENT INSTALLING VENT SYSTEM IN A CHASEHIGH ALTITUDE INSTALLATION CHIMNEYSRELINING SYSTEMS FLUE GAS SPILLAGE TROUBLESHOOTING VENTING PROBLEMSCAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION INSTALLING GAS PIPING TO STOVE LOCATIONCAUTION Use only new, black iron or steel pipe. Inter Installation Items NeededCHECKING GAS CONNECTIONS CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLYPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas ConnectionsINSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2Installing Remote Receiver REMOVING/REPLACING GLASS DOOR Installing 9-Volt Battery in Hand- Held Remote Control UnitFigure 43 - Installing Log No Figure 46 - Installing Log No INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERSFigure 44 - Installing Log No Figure 45 - Installing Log NoLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE OPERATING STOVE WITH B-VENT BURNER SYSTEMGHRCTA Series Operation OPTIONAL REMOTEThermostat Control Operation GHRC Series OperationOPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTAT OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY INSPECTING BURNERSPILOT AND BURNERS CLEANING AND MAINTENANCEWARNING Turn off burner system and let cool before cleaning GLASS DOORREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY If you cannot reach your gas supplier, call the fire department Clean pilot see Cleaning and MainteWARNING If you smell gas Shut off gas supply Do not try to light any applianceSERVICE HINTS REPLACEMENT PARTSTECHNICAL SERVICE WIRING DIAGRAMWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown SPECIFICATIONSACCESSORIES RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC23-4 ILLUSTRATED PARTS BREAKDOWNSBVBNC SBVBPC 23-3PARTS AVAILABLE - NOT SHOWN PARTS LISTPART NUMBER DESCRIPTIONIndicates Color Suffix Designation AMITY SCIVFC* SERIES PSCIVFC* SERIESPART INTERNATIONAL WARRANTY INFORMATIONLIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSIS KEEP THIS WARRANTY