3.Connect one terminal of the wire for the wall thermostat to the THTP termi- nal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 34, page 15. If wires are not connected as shown the ther- mostat will not work.
4.Route the wire to a convenient loca- tion to mount your thermostat (no out- side wall). IMPORTANT: The wire must not exceed 25 feet in length.
The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sun- light, fireplace, or heat and air condi- tioning ducts.
5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.
6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 35).
WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire hazard will occur.
Feed wires through rectangular slots
7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 36).
8.Install the base to the wall with screws provided with thermostat.
9.Move the temperature adjustment back and forth to insure the
10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)
11.Set the temperature adjustment to the desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.
Terminal “W”
W
Terminal “R”
R
Figure 36 - Thermostat Base Terminal “W” and “R”
INSTALLING OPTIONAL WIRELESS
Installing Remote Receiver
1.Open bottom door on stove body.
2.Disconnect wires from THTP and TH on control valve that lead to the switch (see Figure 34, page 15). Discard switch plate, screws, and nuts.
3.Install battery into receiver battery clip and connect to terminals (see Figure 37).
4.Place receiver into valve bracket and align holes (see Figure 38).
5.Use
6.Connect the wires from the receiver to the valve at TH and THTP (see Figure 34, page 15).
Receiver
Terminal
Wires
Battery
Clip
Figure 37 - Installing Battery in Receiver
LO
H
I
OFF | L |
| P |
| I |
| O |
ON | T |
|
Figure 38 - Installing Remote Receiver
Figure 35 - Back View of Thermostat Base
For more information, visit www.desatech.com | 16 | 106828 |