REPLACEMENT PARTS

PARTS UNDER WARRANTYPARTS NOT UNDERTECHNICALWIRING DIAGRAM® SBVBN(C) AND SBVBP(C)

CAST IRON STOVE AND BURNER SYSTEM

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

your name

your address

model and serial numbers of your stove and burner system

how burner system was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Parts De- partment at 1-800-972-7879 for referral in- formation.

When calling DESA International, have ready

model number of your stove and burner system

the replacement part number

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

WIRING DIAGRAM

SERVICE HINTSCAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation af- ter servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

 

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 53 - Blower Wiring Diagram for Thermostat-Controlled Models

SERVICE HINTS

When Gas Pressure is Too Low:

pilot will not stay lit

burners will have delayed ignition

burner system will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

When Gas Quality is Bad:

pilot will not stay lit

burners will produce flames and soot

burner system will backfire when lit

If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier.

For more information, visit www.desatech.com

26

106828

Image 26
Contents FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY Do not try to light any appliance Do not touch any electrical switchWARNINGS SAFETY INFORMATIONSBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEM DANGER Carbon monoxide poisoning may lead to deathPRODUCT IDENTIFICATION PRODUCT FEATURESOWNER’S MANUAL LOCAL CODESetc. in the air exist, may discolor walls PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY STOVE BODY ASSEMBLYContinued INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY INSTALLING OPTIONAL BLOWER ACCESSORYCAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY INSTALLING REAR COVERTYPE B-VENT INSTALLATION Listed B-0 or Greater INSTALLATIONINSTALLATION PRECAUTIONS VENTINGINSTALLING VENT SYSTEM IN A CHASE VENTING INSTALLATIONINSTALLATION OF LISTED B-1 VENT CHECKING VENT CAPACITYRELINING SYSTEMS HIGH ALTITUDE INSTALLATIONCHIMNEYS INSTALLING GAS PIPING TO STOVE LOCATION TROUBLESHOOTING VENTING PROBLEMSCAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION FLUE GAS SPILLAGEInstallation Items Needed CAUTION Use only new, black iron or steel pipe. InterPressure Testing Burner System Gas Connections CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLYPressure Testing Gas Supply Piping System CHECKING GAS CONNECTIONSINSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING GLASS DOORFigure 45 - Installing Log No INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERSFigure 44 - Installing Log No Figure 43 - Installing Log No Figure 46 - Installing Log NoOPERATING STOVE WITH B-VENT BURNER SYSTEM FOR YOUR SAFETY READ BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE LIGHTING INSTRUCTIONSGHRC Series Operation OPTIONAL REMOTEThermostat Control Operation GHRCTA Series OperationINSPECTING BURNERS OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATGLASS DOOR CLEANING AND MAINTENANCEWARNING Turn off burner system and let cool before cleaning PILOT AND BURNERSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYREMEDY Do not try to light any appliance Clean pilot see Cleaning and MainteWARNING If you smell gas Shut off gas supply If you cannot reach your gas supplier, call the fire departmentWIRING DIAGRAM REPLACEMENT PARTSTECHNICAL SERVICE SERVICE HINTSRECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SPECIFICATIONSACCESSORIES WALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown23-3 ILLUSTRATED PARTS BREAKDOWNSBVBNC SBVBPC 23-4DESCRIPTION PARTS LISTPART NUMBER PARTS AVAILABLE - NOT SHOWNAMITY SCIVFC* SERIES PSCIVFC* SERIES Indicates Color Suffix DesignationPART KEEP THIS WARRANTY WARRANTY INFORMATIONLIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSIS INTERNATIONAL