Vanguard Heating SBVBP(C), SBVBN(C) Specifications, Accessories, Sbvbnc, Sbvbpc, Owner’S Manual

Page 27
SPECIFICATIONS

OWNER’S MANUAL

SPECIFICATIONS

 

SBVBN(C)

SBVBP(C)

 

21,000-30,000 Btu/h

20,000-28,000 Btu/h

 

 

 

Gas Type

Natural

Propane/LP

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

 

 

 

Thermal Efficiency

70%

70%

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Stove and Burner System*

27" x 26 1/4" x 20"

27" x 26 1/4" x 20"

 

685.8 x 660.4 x 635mm

685.8 x 660.4 x 635mm

Carton (Insert Only)

23" x 33" x 23"

23" x 33" x 23"

 

584.2 x 838.2 x 584.2mm

584.2 x 838.2 x 584.2mm

 

 

 

Weight, lbs/kg

 

 

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

 

 

 

* When installed in Amity cast iron stove body (SCIVFC Series and PSCIVFC Series).

ACCESSORIES

Purchase these stove and burner system accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800- 432-2382. for information. You can also write to the address listed on the back page of this manual.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC

For all models. Allows the heater to be turned on and off conveniently.

 

 

WARMER

ON AUTO

COOLER

TEMP

 

 

OFF

 

 

WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown)

Allows easy wall access to the operation of your burner system. This will allow you thermostatic control with the convenience of a wall switch.

WALL MOUNTED ON/OFF SWITCH - GWMS2

(Not Shown)

Allows burner system to be turned on and off with a wall switch.

THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610TA

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTA

Allows the burner system to be operated in a manually or thermostatically controlled mode. You can adjust your heat settings and turn the heater on or off without leaving the comfort of your easy chair.

106828

27

For more information, visit www.desatech.com

Image 27
Contents Do not try to light any appliance Do not touch any electrical switch OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GASDANGER Carbon monoxide poisoning may lead to death SAFETY INFORMATIONSBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEM WARNINGSLOCAL CODES PRODUCT FEATURESOWNER’S MANUAL PRODUCT IDENTIFICATIONPRE-INSTALLATION PREPARATION LOCATION AND SPACE REQUIREMENTSetc. in the air exist, may discolor walls STOVE BODY ASSEMBLY CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLYContinued INSTALLING OPTIONAL BLOWER ACCESSORY INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODYINSTALLING REAR COVER CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLYVENTING INSTALLATIONINSTALLATION PRECAUTIONS TYPE B-VENT INSTALLATION Listed B-0 or GreaterCHECKING VENT CAPACITY VENTING INSTALLATIONINSTALLATION OF LISTED B-1 VENT INSTALLING VENT SYSTEM IN A CHASEHIGH ALTITUDE INSTALLATION CHIMNEYSRELINING SYSTEMS FLUE GAS SPILLAGE TROUBLESHOOTING VENTING PROBLEMSCAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION INSTALLING GAS PIPING TO STOVE LOCATIONCAUTION Use only new, black iron or steel pipe. Inter Installation Items NeededCHECKING GAS CONNECTIONS CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLYPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas ConnectionsINSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2Installing Remote Receiver REMOVING/REPLACING GLASS DOOR Installing 9-Volt Battery in Hand- Held Remote Control UnitFigure 43 - Installing Log No Figure 46 - Installing Log No INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERSFigure 44 - Installing Log No Figure 45 - Installing Log NoLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE OPERATING STOVE WITH B-VENT BURNER SYSTEMGHRCTA Series Operation OPTIONAL REMOTEThermostat Control Operation GHRC Series OperationOPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTAT OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY INSPECTING BURNERSPILOT AND BURNERS CLEANING AND MAINTENANCEWARNING Turn off burner system and let cool before cleaning GLASS DOORREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY If you cannot reach your gas supplier, call the fire department Clean pilot see Cleaning and MainteWARNING If you smell gas Shut off gas supply Do not try to light any applianceSERVICE HINTS REPLACEMENT PARTSTECHNICAL SERVICE WIRING DIAGRAMWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown SPECIFICATIONSACCESSORIES RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC23-4 ILLUSTRATED PARTS BREAKDOWNSBVBNC SBVBPC 23-3PARTS AVAILABLE - NOT SHOWN PARTS LISTPART NUMBER DESCRIPTIONIndicates Color Suffix Designation AMITY SCIVFC* SERIES PSCIVFC* SERIESPART INTERNATIONAL WARRANTY INFORMATIONLIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSIS KEEP THIS WARRANTY