Vanguard Heating SBVBN(C) Remedy, Sbvbnc And Sbvbpc Cast Iron Stove And Burner System, Continued

Page 24
REMEDY

Manual backgroundManual backgroundManual backgroundManual background® SBVBN(C) AND SBVBP(C)

CAST IRON STOVE AND BURNER SYSTEM

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 22) or replace burner

 

 

 

 

orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads (see Wiring Diagram,

 

 

properly connected

 

page 26)

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner (see Cleaning and Main-

 

 

 

 

tenance, page 22) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 22) or replace burner

 

 

 

 

orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP or natural gas company

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 22) or replace burner

 

 

 

 

orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

 

 

 

 

 

Burner system produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person

Remote does not function

1. Battery is not installed or battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

www.desatech.com

For more information, visit www.desatech.com

24

106828

Image 24
Contents OWNER’S OPERATION AND INSTALLATION MANUAL FOR YOUR SAFETYFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switchSAFETY INFORMATION SBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEMWARNINGS DANGER Carbon monoxide poisoning may lead to deathPRODUCT FEATURES OWNER’S MANUALPRODUCT IDENTIFICATION LOCAL CODESPRE-INSTALLATION PREPARATION LOCATION AND SPACE REQUIREMENTSetc. in the air exist, may discolor walls CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY STOVE BODY ASSEMBLYContinued INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY INSTALLING OPTIONAL BLOWER ACCESSORYCAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY INSTALLING REAR COVERINSTALLATION INSTALLATION PRECAUTIONSTYPE B-VENT INSTALLATION Listed B-0 or Greater VENTINGVENTING INSTALLATION INSTALLATION OF LISTED B-1 VENTINSTALLING VENT SYSTEM IN A CHASE CHECKING VENT CAPACITYHIGH ALTITUDE INSTALLATION CHIMNEYSRELINING SYSTEMS TROUBLESHOOTING VENTING PROBLEMS CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATIONINSTALLING GAS PIPING TO STOVE LOCATION FLUE GAS SPILLAGEInstallation Items Needed CAUTION Use only new, black iron or steel pipe. InterCONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLY Pressure Testing Gas Supply Piping SystemPressure Testing Burner System Gas Connections CHECKING GAS CONNECTIONSINSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING GLASS DOORINSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERS Figure 44 - Installing Log NoFigure 45 - Installing Log No Figure 43 - Installing Log No Figure 46 - Installing Log NoFOR YOUR SAFETY READ BEFORE LIGHTING MANUAL LIGHTING PROCEDUREOPERATING STOVE WITH B-VENT BURNER SYSTEM LIGHTING INSTRUCTIONSOPTIONAL REMOTE Thermostat Control OperationGHRC Series Operation GHRCTA Series OperationOPERATING OPTIONAL BLOWER ACCESSORY PILOT ASSEMBLYINSPECTING BURNERS OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATCLEANING AND MAINTENANCE WARNING Turn off burner system and let cool before cleaningGLASS DOOR PILOT AND BURNERSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYREMEDY Clean pilot see Cleaning and Mainte WARNING If you smell gas Shut off gas supplyDo not try to light any appliance If you cannot reach your gas supplier, call the fire departmentREPLACEMENT PARTS TECHNICAL SERVICEWIRING DIAGRAM SERVICE HINTSSPECIFICATIONS ACCESSORIESRECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC WALL MOUNTED ON/OFF SWITCH - GWMS2 Not ShownILLUSTRATED PARTS BREAKDOWN SBVBNC SBVBPC23-3 23-4PARTS LIST PART NUMBERDESCRIPTION PARTS AVAILABLE - NOT SHOWNAMITY SCIVFC* SERIES PSCIVFC* SERIES Indicates Color Suffix DesignationPART WARRANTY INFORMATION LIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSISKEEP THIS WARRANTY INTERNATIONAL