Vanguard Heating SBVBP(C) Installing B-Vent Burner System Into Stove Body, Owner’S Manual

Page 7
INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY

Continued

INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY

1.Carefully lift burner system and place into stove body from the rear of stove.

2.Place the left and right grate tops into the top of stove body. Discard center grate top of stove and replace with center grate top provided with burner system.

Center Top Grate (Included with Burner System)

Right Top Grate

Left Top

Grate

Burner

System

Cast Iron

Stove Body

Figure 15 - Installing Burner System Into Cast Iron Stove Body

INSTALLING OPTIONAL BLOWER ACCESSORY

NOTICE: If installing blower in an existing stove burner system with gas connections, shut off gas supply and disconnect heater from gas supply. Contact a quali- fied service person to do this.

1.Remove 4 hex screws securing rear cover to back of stove body (see Figure 16).

2.Separate bottom cover from rear cover by loosening the 8 mounting screws (see Figure 16).

3.Align the holes in the top mounting tabs of blower with the holes in wall of rear cover. Using the 4 screws provided, mount blower and tighten screws se- curely (see Figure 17).

4.Attach thermal switch and bracket to inside rear cover wall with two hex head screws provided as shown in Fig- ure 17. After securing bracket to rear

cover, carefully bend along existing bend line on bracket to almost a 90° angle (see Figure 17). This will allow thermal switch to be positioned against stove rear wall and sense temperature when in operating mode.

Hex Screws

Stove Body

Speed

Blower Control

Control Control

Knob Shaft

Locknut

TOP VIEW

Thermal Switch

and Bracket

Screws

Mounting

Holes

Blower

 

Assembly

Mounting Holes

Figure 17 - Blower Assembly, Speed Control, and Thermal Switch Locations

Rear Cover

Mounting

Screws

INSTALLING OPTIONAL BLOWER ACCESSORYManual backgroundHex

Screws

Mounting

Screws

Bottom Cover

Mounting

Screws

Figure 16 - Removing Rear Cover and Bottom Cover from Stove Body

Continued

106828

7

For more information, visit www.desatech.com

Image 7
Contents Do not try to light any appliance Do not touch any electrical switch OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GASDANGER Carbon monoxide poisoning may lead to death SAFETY INFORMATIONSBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEM WARNINGSLOCAL CODES PRODUCT FEATURESOWNER’S MANUAL PRODUCT IDENTIFICATIONLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATIONetc. in the air exist, may discolor walls STOVE BODY ASSEMBLY CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLYContinued INSTALLING OPTIONAL BLOWER ACCESSORY INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODYINSTALLING REAR COVER CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLYVENTING INSTALLATIONINSTALLATION PRECAUTIONS TYPE B-VENT INSTALLATION Listed B-0 or GreaterCHECKING VENT CAPACITY VENTING INSTALLATIONINSTALLATION OF LISTED B-1 VENT INSTALLING VENT SYSTEM IN A CHASECHIMNEYS HIGH ALTITUDE INSTALLATIONRELINING SYSTEMS FLUE GAS SPILLAGE TROUBLESHOOTING VENTING PROBLEMSCAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION INSTALLING GAS PIPING TO STOVE LOCATIONCAUTION Use only new, black iron or steel pipe. Inter Installation Items NeededCHECKING GAS CONNECTIONS CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLYPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas ConnectionsINSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2Installing Remote Receiver REMOVING/REPLACING GLASS DOOR Installing 9-Volt Battery in Hand- Held Remote Control UnitFigure 43 - Installing Log No Figure 46 - Installing Log No INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERSFigure 44 - Installing Log No Figure 45 - Installing Log NoLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE OPERATING STOVE WITH B-VENT BURNER SYSTEMGHRCTA Series Operation OPTIONAL REMOTEThermostat Control Operation GHRC Series OperationOPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTAT OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY INSPECTING BURNERSPILOT AND BURNERS CLEANING AND MAINTENANCEWARNING Turn off burner system and let cool before cleaning GLASS DOORREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY If you cannot reach your gas supplier, call the fire department Clean pilot see Cleaning and MainteWARNING If you smell gas Shut off gas supply Do not try to light any applianceSERVICE HINTS REPLACEMENT PARTSTECHNICAL SERVICE WIRING DIAGRAMWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown SPECIFICATIONSACCESSORIES RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC23-4 ILLUSTRATED PARTS BREAKDOWNSBVBNC SBVBPC 23-3PARTS AVAILABLE - NOT SHOWN PARTS LISTPART NUMBER DESCRIPTIONIndicates Color Suffix Designation AMITY SCIVFC* SERIES PSCIVFC* SERIESPART INTERNATIONAL WARRANTY INFORMATIONLIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSIS KEEP THIS WARRANTY