Vanguard Heating SBVBP(C), SBVBN(C) Installation Items Needed, Owner’S Manual, Continued

Page 13
Installation Items Needed

OWNER’S MANUAL

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Installation Items Needed

Before installing stove and burner system, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

* An CSA/AGA design-certified equip-

ment shutoff valve with 1/8" NPT tap is an

acceptable alternative to test gauge connec-

tion. Purchase the CSA/AGA design-certi-

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system (see Figure 29).

Check your building codes for any special requirements for locating equipment shutoff valve to stoves.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

 CAUTION: Use only new, black iron or steel pipe. Inter- CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 29. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

fied equipment shutoff valve from your

dealer.

Figure 28 - External Regulator with Vent Pointing Down (Propane/LP Only)

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 28. Pointing the vent down protects it from freezing rain or sleet.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter-

Approved Flexible

Gas Line

3" Minimum

CSA/AGA Design- Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Natural - From Gas

Meter (5" W.C. to 10.5"

W.C. Pressure )

LP - From External Regulator (11" W.C. to 14" W.C. Pressure)

nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner sys- tem. If pipe is too small, undue loss of pressure will occur.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

*The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

Figure 29 - Gas Connection

Continued

106828

13

For more information, visit www.desatech.com

Image 13
Contents FOR YOUR SAFETY OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switchSBVBNC AND SBVBPC CAST IRON STOVE AND BURNER SYSTEM SAFETY INFORMATIONWARNINGS DANGER Carbon monoxide poisoning may lead to deathOWNER’S MANUAL PRODUCT FEATURESPRODUCT IDENTIFICATION LOCAL CODESLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATIONetc. in the air exist, may discolor walls STOVE BODY ASSEMBLY CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLYContinued INSTALLING OPTIONAL BLOWER ACCESSORY INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODYINSTALLING REAR COVER CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLYINSTALLATION PRECAUTIONS INSTALLATIONTYPE B-VENT INSTALLATION Listed B-0 or Greater VENTINGINSTALLATION OF LISTED B-1 VENT VENTING INSTALLATIONINSTALLING VENT SYSTEM IN A CHASE CHECKING VENT CAPACITYCHIMNEYS HIGH ALTITUDE INSTALLATIONRELINING SYSTEMS CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION TROUBLESHOOTING VENTING PROBLEMSINSTALLING GAS PIPING TO STOVE LOCATION FLUE GAS SPILLAGECAUTION Use only new, black iron or steel pipe. Inter Installation Items NeededPressure Testing Gas Supply Piping System CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLYPressure Testing Burner System Gas Connections CHECKING GAS CONNECTIONSINSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2Installing Remote Receiver REMOVING/REPLACING GLASS DOOR Installing 9-Volt Battery in Hand- Held Remote Control UnitFigure 44 - Installing Log No INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERSFigure 45 - Installing Log No Figure 43 - Installing Log No Figure 46 - Installing Log NoMANUAL LIGHTING PROCEDURE FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING STOVE WITH B-VENT BURNER SYSTEM LIGHTING INSTRUCTIONSThermostat Control Operation OPTIONAL REMOTEGHRC Series Operation GHRCTA Series OperationPILOT ASSEMBLY OPERATING OPTIONAL BLOWER ACCESSORYINSPECTING BURNERS OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATWARNING Turn off burner system and let cool before cleaning CLEANING AND MAINTENANCEGLASS DOOR PILOT AND BURNERSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYREMEDY WARNING If you smell gas Shut off gas supply Clean pilot see Cleaning and MainteDo not try to light any appliance If you cannot reach your gas supplier, call the fire departmentTECHNICAL SERVICE REPLACEMENT PARTSWIRING DIAGRAM SERVICE HINTSACCESSORIES SPECIFICATIONSRECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC WALL MOUNTED ON/OFF SWITCH - GWMS2 Not ShownSBVBNC SBVBPC ILLUSTRATED PARTS BREAKDOWN23-3 23-4PART NUMBER PARTS LISTDESCRIPTION PARTS AVAILABLE - NOT SHOWNIndicates Color Suffix Designation AMITY SCIVFC* SERIES PSCIVFC* SERIESPART LIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY STOVE CHASSIS WARRANTY INFORMATIONKEEP THIS WARRANTY INTERNATIONAL