Ratings
A
Installation & Operation Manual
SME
H
Knight Wall Mount Boiler
AHRI Rating
|
| Input |
| Heating | Net |
| |
Model Number |
|
| Capacity | AHRI | AFUE | ||
| MBH |
| MBH | Ratings | % | ||
|
|
|
|
| |||
Note: Change |
| (Note 5) |
|
| Water, |
| |
“N” to “L” for |
|
|
|
|
| MBH |
|
L.P. gas models. |
|
|
|
|
|
|
|
| Min |
| Max |
| (Note 2, 8) | (Note 3, 8) | (Note 1, 8) |
WHN055 | 11 |
| 55 | 51 | 44 | 96 | |
|
|
|
|
|
|
|
|
WHN085 | 17 |
| 85 | 79 | 69 | 96 | |
|
|
|
|
|
|
|
|
WHN110 | 22 |
| 110 | 102 | 89 | 96 | |
|
|
|
|
|
|
|
|
WHN155 | 31 |
| 155 | 144 | 125 | 96 | |
|
|
|
|
|
|
|
|
WHN199 | 40 |
| 199 | 186 | 162 | 96 | |
|
|
|
|
|
|
|
|
WHN285 | 57 |
| 285 | 265 | 230 | 96 | |
|
|
|
|
|
|
|
|
WHN399 | 80 |
| 399 | 379 | 330 | 95 | |
|
|
|
|
|
|
|
|
Other Specifications
|
|
| Vent/Air |
Boiler Water | Water | Gas | Size |
Content |
| ||
Connections | Connections |
| |
Gallons |
| ||
|
|
| |
|
|
| (Note 4) |
|
|
|
|
2.5 | 1" | 1/2" | 2" |
|
|
|
|
2.5 | 1" | 1/2" | 2" |
|
|
|
|
3.5 | 1" | 1/2" | 3" |
|
|
|
|
3.5 | 1" | 1/2" | 3" |
|
|
|
|
5.0 | 1 1/4" | 1/2" | 3" |
|
|
|
|
5.0 | 1 1/4" | 1/2" | 3" |
|
|
|
|
6.5 | 1 1/2" | 3/4" | 4" |
|
|
|
|
NOTICE | Maximum allowed working pressure is located on the rating plate. | ||
Notes: |
| 7. The Knight Wall Mount boiler input rate, on some models, | |
| is reduced for vent lengths beyond the minimum. Two inch | ||
1. As an Energy Star Partner, Lochinvar has determined that | |||
vent will reduce Models WH(N,L) 055, WH(N,L) 085 and | |||
Knight wall mount boilers meet the Energy Star guidelines | |||
WH(N,L)110 by 0.6%, 0.94%, and 1.2% for every 10 feet | |||
for energy efficiency. | |||
of vent. Three inch vent will reduce Models WH(N,L)155, | |||
2. The ratings are based on standard test procedures prescribed | |||
WH(N,L)199 and WH(N,L) 285 by 0.3%, 0.5%, and 0.6% | |||
by the United States Department of Energy. | for every 10 feet of vent. Four inch vent will reduce Model | ||
3. Net AHRI ratings are based on net installed radiation of | WH(N,L) 399 by 0.4% for every 10 feet of vent. | ||
sufficient quantity for the requirements of the building | 8. Ratings have been confirmed by the Hydronics Section of | ||
and nothing need be added for normal piping and pickup. | AHRI. Model 399 has a thermal efficiency rating. | ||
Ratings are based on a piping and pickup allowance of 1.15. | 9. Knight wall mount boilers comply with the requirements | ||
4. Knight wall mount boilers require special gas venting. Use | of | ||
only the vent materials and methods specified in the Knight | operation control. The manual reset high limit provided | ||
Wall Mount Installation and Operation Manual. | with the Knight wall mount boiler is listed to UL353. | ||
5. Standard Knight wall mount boilers are equipped to operate |
| ||
from sea level to 4,500 feet only with no adjustments. The |
| ||
boiler will |
| ||
up to 4,500 feet. |
| ||
6. High altitude Knight wall mount boilers are equipped | UNIT EQUIPPED FOR | ||
to operate from 3,000 to 12,000 feet only with no field | HIGH ALTITUDE | ||
|
| ||
adjustments. The boiler will | 3,000FT TO 12,000FT | ||
feet above 3,000 feet. High altitude models are manufactured |
| ||
with a different control module for altitude operation, but |
| ||
the operation given in this manual remains the same as the |
| ||
standard boilers. A high altitude label (as shown in FIG. A) |
| ||
is also affixed to the unit. |
|
6 |
| Figure A High Altitude Label Location |
|