Turbo Chef Technologies Tornado 2 Certifications Packaging, Ngcew 3 Phase, WYE, 50 Hz

Page 10

2 O v erview of the Tornado Oven

Accessories (Additional Charge)

o24” (610 mm) stainless steel oven stand with locking casters

o18” (457 mm) stainless steel oven stand with locking casters

Certifications

Packaging

All ovens are packaged in a double-wall corrugated box with integrated corrugated skids.

El ec t r i c al Specifications

NGC (1 Phase, 60 Hz )

 

Operating Voltage

208/240 VAC*

Current Draw

30 Amps

Phase

1 Phase

Frequency

60 Hz

Plug

neMA 6-30

Max Input

5990/6675 watts

Microwave Input Power

3500 watts

*Smart Voltage Sensor Technology automatically senses the supply voltage and allows the user to configure the oven to the correct setting (208 or 240) with the touch of a button.

note: The Smart Voltage Sensor Technology does not compensate for lack of, or over voltage situations. It is the responsibility of the owner to supply voltage to the unit according to the above specifications.

NGCEW (3 Phase, WYE, 50 Hz)

Operating Voltage

400 VAC

Current Draw

16 Amps

Phase/Frequency

3 Phase/50 Hz

Plug

ieC 309, 5 PIN (32 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

NGCED (3 Phase, Delta, 50 Hz)

Operating Voltage

230 VAC

Current Draw

30 Amps

Phase/Frequency

3 Phase/50 Hz

Plug

ieC 309, 4 PIN (32 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

NGCUK (1 Phase, 50 Hz)

 

Operating Voltage

230 VAC

Current Draw

30 Amps

Phase/Frequency

1 Phase/50 Hz

Plug

ieC 309, 3 PIN (32 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

NGCBK (1 Phase, 60 Hz)

 

Operating Voltage

220 VAC

Current Draw

30 Amps

Phase/Frequency

1 Phase/60 Hz

Plug

ieC 309, 3 PIN (32 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

NGCJD (3 Phase, 50/60 Hz)

Operating Voltage

200 VAC

Current Draw

30 Amps

Phase/Frequency

3 Phase/50 or 60 Hz

Plug

PSE, 4-blade (30 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

NGCJK (1 Phase, 50/60 Hz)

Operating Voltage

200 VAC

Current Draw

30 Amps

Phase/Frequency

1 Phase/50 or 60 Hz

Plug

PSE, 3-blade (30 A)

Heaters Input Power

6300 watts

Microwave Input Power

3500 watts

Note: Model NGC is typically the oven model used in North America. NGCEW, NGCED, NGCUK, NGCBK, NGCJD, and NGCJK are primarily used in international markets and locations.

Image 10
Contents For the turbochef tornado and tornado 2TM rapid cook ovens Page For service or information Thoroughly before installing or servicing this equipment Table of Contents Limited Warranty Important Safety Instructions Grounding Instructions Overview of the Tornado Oven Standard FeaturesConstruction exterior Ngced 3 Phase, Delta, 50 Hz Ngcew 3 Phase, WYE, 50 HzCertifications Packaging How the Technology Works How the Technology WorksDelivery and Initial Inspection Assembly and InstallationOven Location and Placement Lifting the OvenSecuring Oven to Cart Figure Double Stacking Ovens FigureOven Assembly Built-In Installation FigureVentilation Requirements As s em bly and installation Oven Restraint Kit P/N TC3-024224 610mm Cart with a Single Oven Lo adi n g a menu from a smart card This page left intentionally blank Common Operating Terms Cook Cavity Set Temperature IR Set TemperatureCook Cavity Actual Temperature Idle IR Set TemperatureOperating the Tornado Oven Initial Power-Up Power-UpO k i n g instructions Done Changing the Edit Pin Number Editing a Food ItemEnter Cook Time Screen Snooze Mode Done ScreenThis page left intentionally blank Development Methodology Recipe Development and Cooking TipsExample 1 Frozen Pizza Importance of Consistency Example 2 French Fries & Frozen Puff Dough ItemsDon’t be Afraid to Experiment Dual-Ovenable Paper Board Baking Papers/SheetsNordicWare PlasticsWhat Not To Use Clean Oven Interior Remove the Lower Access PanelRemove and Clean the Cooking Surface Clean Lower Access Panel AreaApply Oven Guard and Clean Oven Exterior Error Codes/Faults, Possible Causes and Suggested Remedies F1 Blower Running Ca t al yt i c Converter North America Limited Warranty R t h america limited warranty Iscla i mer of Damages International Limited Warranty Nter n a t i o n al limited warranty R r a n ty parts return Global Operations