Section 1: Safety Rules

DANGER

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground circuit fault interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

DANGER

Storage batteries give off explosive hydrogen gas during recharging.

Hydrogen gas stays around battery for a long time after battery has been charged.

Slightest spark will ignite hydrogen and cause explosion.

You can be blinded or severely injured.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery fluid will cause severe chemical burns.

DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

Wear protective goggles, rubber apron, and rubber gloves.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing gas cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN OPERATING EQUIPMENT

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.

3

Image 3
Contents Questions? Preguntas? Helpline 1-888-611-6708 M-F8-5 CT Portable Generator / Generador Portátil Model / ModeloTable of Contents Safety RulesEquipment Description Generator produces powerful voltage Unintentional sparking can result in fire or electric shock Know Your Generator Features and Controls SectionRemove Generator From Carton AssemblyAttach Negative Battery Cable To installAdd Engine Oil and Fuel AssemblyBefore Starting the Engine Attach HandleUsing the Generator Section OperationOperating Generator Stopping the Engine Jump Start ProcedureConnecting Electrical Loads OperationCharging a Battery How to Use the Battery ChargerTo recharge 12 Volt batteries, proceed as follows Permanent Cold Weather Shelter Cold Weather Generator Adapter Operation Cord SET120/240 Volt AC, 30 Amp, Locking Receptacle ReceptaclesVolt DC, 10 Amp Receptacle Volt AC, 20 Amp, Duplex ReceptaclesExample Power ManagementDont Overload Generator CapacitySection Maintenance General Maintenance RecommendationsEngine Maintenance Generator Cleaning MaintenanceGenerator Maintenance Battery MaintenanceEngine Storage Other Storage Tips StorageStorage Generator StorageTroubleshooting TroubleshootingProblem Cause Correction Schematic Section Wiring Diagram and SchematicWiring Diagram Wiring Diagram and SchematicExploded View Main Unit Section Exploded Views and Parts ListsParts Not Illustrated Exploded Views and Parts ListsParts List Main Unit DescriptionAC Control Panel Exploded View & Parts List DC Control Panel Exploded View & Parts List Alternator Exploded View & Parts List Page Reglas DE Seguridad Reglas de SeguridadTabla DE Contenidos Descripción DEL EquipoPeligro Sección 1 Reglas de SeguridadPrecaución Sección 1 Instrucciones de SeguridadCaracterísticas y Mandos Conozca SU GeneradorCulatazo el Principio Usó para comenzar motor Conecte el Cable Negativo de la Batería MontajeMontaje Para Retirar El Generador De La CajaAgregar Aceite al Motor y Combustible Sección 3 MontajeAntes DE Darle Arranque AL Motor Fije el AsaOperación USO DEL GeneradorOperando EL Generador Precaución Parado Del Motor Sección 4 OperaciónProcedimiento de Arranque en Puente Conexion De Cargas ElectricasCargador de Batería Carga de la BateriaFigura 24 Refugio Frío Permanente del Tiempo Operación Durante UN Clima FríoJuego DE Cables DEL Adaptador DEL Generador ReceptáculosTomacorrientes de 12 Voltios DC 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 20 Amp, Receptáculos DoblesEjemplo No Sobrecargue EL GeneradorCapacidad Control de la EnergíaCambio del Aceite MantenimientoRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorPara Limpiar el Generador Sección 5 MantenimientoMantenimiento del Generador Mantenimiento de la BateríaAlmacenando el Motor AlmacenamientoAlmacenamiento Almacenando el GeneradorDiagnosticos de Averías Problemo Causa AccionDiagnositicos DE Averías Efectiva desde el 12 ro de Noviembre Equipo Para Uso Del Consumidor Para Uso ComercialAcerca de la seguridad de su equipo TROY-BILT Owner Warranty Policy Effective November 12 About your equipment warrantyEquipment Consumer Use Commercial Use

1925 specifications

The Troy-Bilt 1925 is a versatile and powerful lawn care machine, designed to handle a myriad of landscaping tasks with ease and efficiency. Renowned for its robust construction and user-friendly features, the Troy-Bilt 1925 is an ideal choice for both residential homeowners and professional landscapers alike.

One of its standout features is the powerful engine. The Troy-Bilt 1925 is equipped with a reliable 25 HP engine that delivers plenty of power to tackle even the toughest mowing conditions. Whether you're mowing dense grass, tackling overgrown weeds, or navigating steep terrain, this engine offers the necessary torque and performance to get the job done without stalling or straining.

The cutting deck is another impressive aspect of the Troy-Bilt 1925. With a generous cutting width of 54 inches, users can cover large areas efficiently, reducing the time spent mowing. The deck height is easily adjustable, allowing for customized cutting heights to suit different grass types and lengths. Users can achieve a perfectly manicured lawn with minimal effort.

In terms of technology, the Troy-Bilt 1925 features advanced cutting system technology that enhances the quality of cut and offers superior grass discharge. The integrated side discharge and mulch capabilities provide options for grass management, catering to different user preferences. Additionally, the large-capacity fuel tank ensures extended mowing sessions without frequent refueling interruptions.

Comfort and ease of use are paramount in the design of the Troy-Bilt 1925. The ergonomic seating and dashboard controls ensure that operators remain comfortable during longer mowing sessions. The intuitive control layout allows for easy maneuverability, while the responsive steering system enhances navigation around obstacles such as trees and flower beds.

Moreover, the Troy-Bilt 1925 is built to last, featuring a durable frame and high-quality components that withstand the rigors of consistent use. The stability and traction provided by its heavy-duty tires ensure safe operation on various terrains.

In conclusion, the Troy-Bilt 1925 is an excellent choice for anyone seeking a reliable, efficient, and powerful lawn care machine. With its combination of a strong engine, wide cutting deck, advanced technology, and user-centric design, it stands out as a leader in outdoor power equipment, capable of maintaining impressive lawns and landscapes with ease and precision.