Troy-Bilt 1925 owner manual Section Operation, Using the Generator, Operating Generator

Page 8

Section Operation

4

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

OPERATING THE

GENERATOR

CAUTION

Exceeding generator’s wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator” on page 13.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

IMPORTANT: Always unplug the battery float charger before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Follow start instruction steps in numerical order:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2.Follow start instructions given in engine owner’s manual and turn start switch on generator to “Start” position (Figure 3).To prolong life of starter components, DO NOT hold starter switch in “Start” position for more than 15 seconds, and pause for 1 minute.

Figure 3 — Starter Switch

NOTE: If engine starts but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.This unit may be equipped with a low oil protection device. See engine manual.

8

Image 8
Contents Portable Generator / Generador Portátil Model / Modelo Questions? Preguntas? Helpline 1-888-611-6708 M-F8-5 CTEquipment Description Table of ContentsSafety Rules Generator produces powerful voltage Unintentional sparking can result in fire or electric shock Features and Controls Section Know Your GeneratorAssembly Attach Negative Battery CableTo install Remove Generator From CartonAssembly Before Starting the EngineAttach Handle Add Engine Oil and FuelOperating Generator Using the GeneratorSection Operation Jump Start Procedure Connecting Electrical LoadsOperation Stopping the EngineTo recharge 12 Volt batteries, proceed as follows Charging a BatteryHow to Use the Battery Charger Cold Weather Generator Adapter Operation Cord SET Permanent Cold Weather ShelterReceptacles Volt DC, 10 Amp ReceptacleVolt AC, 20 Amp, Duplex Receptacles 120/240 Volt AC, 30 Amp, Locking ReceptaclePower Management Dont Overload GeneratorCapacity ExampleEngine Maintenance Section MaintenanceGeneral Maintenance Recommendations Maintenance Generator MaintenanceBattery Maintenance Generator CleaningStorage StorageGenerator Storage Engine Storage Other Storage TipsProblem Cause Correction TroubleshootingTroubleshooting Section Wiring Diagram and Schematic SchematicWiring Diagram and Schematic Wiring DiagramSection Exploded Views and Parts Lists Exploded View Main UnitExploded Views and Parts Lists Parts List Main UnitDescription Parts Not IllustratedAC Control Panel Exploded View & Parts List DC Control Panel Exploded View & Parts List Alternator Exploded View & Parts List Page Reglas de Seguridad Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadSección 1 Reglas de Seguridad PeligroSección 1 Instrucciones de Seguridad PrecauciónCulatazo el Principio Usó para comenzar motor Características y MandosConozca SU Generador Montaje MontajePara Retirar El Generador De La Caja Conecte el Cable Negativo de la BateríaSección 3 Montaje Antes DE Darle Arranque AL MotorFije el Asa Agregar Aceite al Motor y CombustibleOperando EL Generador Precaución OperaciónUSO DEL Generador Sección 4 Operación Procedimiento de Arranque en PuenteConexion De Cargas Electricas Parado Del MotorCarga de la Bateria Cargador de BateríaOperación Durante UN Clima Frío Figura 24 Refugio Frío Permanente del TiempoTomacorrientes de 12 Voltios DC Juego DE Cables DEL Adaptador DEL GeneradorReceptáculos Volt AC, 20 Amp, Receptáculos Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadNo Sobrecargue EL Generador CapacidadControl de la Energía EjemploMantenimiento Recomendaciones Generales DE MantenimientoMantenimiento del Motor Cambio del AceiteSección 5 Mantenimiento Mantenimiento del GeneradorMantenimiento de la Batería Para Limpiar el GeneradorAlmacenamiento AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Diagnosticos de AveríasProblemo Causa Accion Acerca de la seguridad de su equipo Efectiva desde el 12 ro de NoviembreEquipo Para Uso Del Consumidor Para Uso Comercial Equipment Consumer Use Commercial Use TROY-BILT Owner Warranty Policy Effective November 12About your equipment warranty

1925 specifications

The Troy-Bilt 1925 is a versatile and powerful lawn care machine, designed to handle a myriad of landscaping tasks with ease and efficiency. Renowned for its robust construction and user-friendly features, the Troy-Bilt 1925 is an ideal choice for both residential homeowners and professional landscapers alike.

One of its standout features is the powerful engine. The Troy-Bilt 1925 is equipped with a reliable 25 HP engine that delivers plenty of power to tackle even the toughest mowing conditions. Whether you're mowing dense grass, tackling overgrown weeds, or navigating steep terrain, this engine offers the necessary torque and performance to get the job done without stalling or straining.

The cutting deck is another impressive aspect of the Troy-Bilt 1925. With a generous cutting width of 54 inches, users can cover large areas efficiently, reducing the time spent mowing. The deck height is easily adjustable, allowing for customized cutting heights to suit different grass types and lengths. Users can achieve a perfectly manicured lawn with minimal effort.

In terms of technology, the Troy-Bilt 1925 features advanced cutting system technology that enhances the quality of cut and offers superior grass discharge. The integrated side discharge and mulch capabilities provide options for grass management, catering to different user preferences. Additionally, the large-capacity fuel tank ensures extended mowing sessions without frequent refueling interruptions.

Comfort and ease of use are paramount in the design of the Troy-Bilt 1925. The ergonomic seating and dashboard controls ensure that operators remain comfortable during longer mowing sessions. The intuitive control layout allows for easy maneuverability, while the responsive steering system enhances navigation around obstacles such as trees and flower beds.

Moreover, the Troy-Bilt 1925 is built to last, featuring a durable frame and high-quality components that withstand the rigors of consistent use. The stability and traction provided by its heavy-duty tires ensure safe operation on various terrains.

In conclusion, the Troy-Bilt 1925 is an excellent choice for anyone seeking a reliable, efficient, and powerful lawn care machine. With its combination of a strong engine, wide cutting deck, advanced technology, and user-centric design, it stands out as a leader in outdoor power equipment, capable of maintaining impressive lawns and landscapes with ease and precision.