Multiquip C1870300404 DCA-220SSJ/SSJU Generator OUTPUTS/ Gauge Reading, Maximum Amps

Page 45

DCA-220SSJ/SSJU — GENERATOR OUTPUTS/ GAUGE READING

Maximum Amps

Table 10 shows the maximum amps the generator can pro- vide. DO NOT exceed the maximum amps as listed.

Table 10. Generator Maximum Amps

Model

DCA220SSJ

 

 

Rated Voltage

Maximum Amps

 

 

Single Phase

488.9 amps (4 wire)

120 Volt

 

 

 

Single Phase

244.4 amps (4 wire)

240 Volt

 

 

 

Three Phase

529 amps

240 Volt

 

 

 

Three Phase

264 amps

480 Volt

 

 

 

How to Read the Output Terminal Gauge.

The AC ammeter and AC voltmeter change-over switches on the control panel DO NOT effect the generator output. They are provided to help observe how much power is being supplied, produced at the UVWO terminals lugs.

When the voltage change-over board (Figure 16) is jumpered for 3Ø, 240V operation place the AC Voltmeter Change- Over Switch (Figure 17) to the W-U position and the AC Ammeter Change-Over Switch (Figure 19) to the U or W position. Use the AC voltmeter or AC ammeter (Figures 18 and 20) to read the output on the selected leg of the UVWO terminals.

Figure 17. AC Voltmeter

Figure 18. AC Voltmeter Gauge

Change-Over Switch

(Volt reading on W-U Lug)

Figure 19. AC Ammeter

Figure 20. AC Ammeter

Change-Over Switch

(Amp reading on U lug)

NOTICE

The ammeter gauge will only show a reading when the output terminal lugs are connected to a load and in use.

DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #1 (02/28/14) — PAGE 45

Image 45
Contents Model DCA220SSJ/SSJU DCA-220SSJ/SSJU Proposition 65WARNING DCA-220SSJ/SSJU Note DCA-220SSJ/SSJU -TABLE of Contents Ordering parts has never been easier DCA-220SSJ/SSJU Parts Ordering ProceduresDCA-220SSJ/SSJU Specifications Dimensions DCA-220SSJ/SSJU Dimensions TOP, Side and FrontHazard Symbols DCA-220SSJ/SSJU Safety Message Alert SymbolsDCA-220SSJ/SSJU Safety Message Alert Symbols DCA-220SSJ/SSJU Rules for Safe Operation General SafetyDrugs or alcohol BurnsElectrical Safety DCA-220SSJ/SSJU Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-220SSJ/SSJU Generator DecalsGenerator Decals Cont inued DCA-220SSJ/SSJU Generator DecalsTypical Generator Grounding Application DCA-220SSJ/SSJU InstallationOutdoor Installation DCA-220SSJ/SSJU InstallationIndoor Installation MountingDCA-220SSJ/SSJU General Information Major Components DCA-220SSJ/SSJU Major ComponentsDCA-220SSJ/SSJU Diagnostic Display Menu Button Press this button to enter or exit menu screensDisplay Parameters First Time Start Up DCA-220SSJ/SSJU Diagnostic DisplayNext item down Main Menu NavigationStored Fault Codes Diagnostic CodeEngine Configuration Data To make a selectionDCA-220SSJ/SSJU Diagnostic Display DCA-220SSJ/SSJU Diagnostic Display Display will return to the single or four parameter screen Auxiliary Gage FaultActive Fault Codes Shut Down Codes Backlight AdjustmentCode from an engine control unit the single or four DamageContrast Adjustment IntensityIs highlighted Select Units Setup 1- Up DisplayOnce the Setup 1-up Display menu icon has been Setup menuUp display function Automatic Scan on Select the 4-Up Custom Setup from the 4-Up Setup menu Setup 4-Up DisplayHighlighted Engine OIL TemperatureGage Data is selected the PowerView will When the gage data has cleared, the displayVersion currently in the diagnostic display Half duplexTouch the Menu button again to return to the Main MenuTouch the Menu Button Highlight it, then touch Enter Glossary Troubleshooting information DCA-220SSJ/SSJU Diagnostic DisplayECU did not respond to the PowerView request No parameter selected for this 4- UP quadrantDCA-220SSJ/SSJU Generator Control Panel Fuel Gauge Indicates amount of diesel fuel available DCA-220SSJ/SSJU Engine Operating PanelAuto On/Off Engine Controller Mpec DCA-220SSJ/SSJU Engine Operating PanelOutput Terminal Familiarization DCA-220SSJ/SSJU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-220SSJ/SSJU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadDCA-220SSJ/SSJU Load Application DCA-220SSJ/SSJU Generator Outputs How to Read the Output Terminal Gauge DCA-220SSJ/SSJU Generator OUTPUTS/ Gauge ReadingMaximum Amps Uvwo Terminal Output Voltages DCA-220SSJ/SSJU Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages DCA-220SSJ/SSJU Output Terminal Panel Connections1Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesCircuit Breakers DCA-220SSJ/SSJU SetupLubrication Oil Fuel CheckDCA-220SSJ/SSJU Setup Refueling ProcedureONLY! use #2 diesel fuel when refueling Air Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorPlace the engine speed switch in the LOW down position DCA-220SSJ/SSJU Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsEngine Speed Switch High Starting Auto Mode No LoadTachometer Gauge Place the Mpec Control Switch in the Auto position Place the engine speed switch in the High positionEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-220SSJ/SSJU Maintenance Engine DCA-220SSJ/SSJU Maintenance Engine DCA-220SSJ/SSJU Maintenance HEATER/CHARGER Trailer Maintenance DCA-220SSJ/SSJU Maintenance TrailerBrakes Brake AdjustmentCheck the wheel and drum for free rotation Hydraulic Surge BrakesTires/Wheels/Lug Nuts TireWear/InflationSuspension Lug Nut Torque Requirements DCA-220SSJ/SSJU Maintenance TrailerStart all wheel lug nuts by hand Never use an pneumatic air gun to tighten wheel lug nutsTrailer/Towing Vehicle Wiring Diagram DCA-220SSJ/SSJU -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-220SSJ/SSJU Generatorwiring DiagramEngine Wiring Diagram DCA-220SSJ/SSJU Enginewiring DiagramGenerator Troubleshooting DCA-220SSJ/SSJU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-220SSJ/SSJU -TROUBLESHOOTING Engine ControllerDCA-220SSJ/SSJU Operation and Parts Manual REV. #1 02/28/14 QTY. Column DCA220SSJ/SSJU Explanation of Code in Remarks ColumnDescription DCA220SSJ/SSJU Suggested Spare PartsDCA220SSJ/SSJU Generator Assy DCA220SSJ/SSJU Generator Assy DCA220SSJ/SSJU- Generator ASSY. DCA220SSJ/SSJU Generator ASSY. DCA220SSJ/SSJU Control Panel Assy DCA220SSJ/SSJU- Control Panel Assy DCA220SSJ/SSJU Control BOX Assy DCA220SSJ/SSJU Control BOX Assy DCA220SSJ/SSJU Control BOX ASSY. DCA220SSJ/SSJU Control BOX ASSY. DCA220SSJ/SSJU- Engine and Radiator Assy DCA220SSJ/SSJU Engine and Radiator Assy DCA220SSJ/SSJU Engine and Radiator Assy 32A M4493601204 M4310301203M4310300903 M4310301003DCA220SSJ/SSJU Engine and Radiator Assy 0269200660 06020210700802081003 M9300000203DCA220SSJ/SSJU Outputterminal Assy DCA220SSJ/SSJU Outputterminal Assy DCA220SSJ/SSJU Outputterminal ASSY. DCA220SSJ/SSJU Outputterminal ASSY. DCA220SSJ/SSJU Battery Assy DCA220SSJ/SSJU Battery Assy DCA220SSJ/SSJU Muffler Assy DCA220SSJ/SSJU Muffler Assy DCA220SSJ/SSJU Fueltank Assy DCA220SSJ/SSJU Fueltank Assy DCA220SSJ/SSJU Enclosure Assy DCA220SSJ/SSJU Enclosure Assy DCA220SSJ/SSJU Enclosure ASSY. DCA220SSJ/SSJU Enclosure ASSY. DCA220SSJ/SSJU Enclosure ASSY. DCA220SSJ/SSJU Enclosure ASSY. DCA220SSJ/SSJU Enclosure ASSY. 62A 0030006000 M9113000102M4453600004 M4453600104DCA220SSJ/SSJU Rubber Seals Assy DCA220SSJ/SSJU Rubber Seals Assy DCA220SSJ/SSJU Nameplate and Decals Assy DCA220SSJ/SSJU Nameplate and Decals Assy DCA220SSJ/SSJU Nameplate and Decals ASSY. DCA220SSJ/SSJU Nameplate and Decals ASSY. Freight Policy Terms and Conditions of Sale PartsDCA-220SSJ/SSJU Operation and Parts Manual REV. #1 02/28/14 HERE’S HOW to GET Help

C1870300404, M4870300104B specifications

Multiquip, a leading manufacturer in the construction and industrial sectors, offers a wide range of durable and reliable products. Among its extensive portfolio, two notable models stand out: the M4870300104B and the C1870300404. These models are particularly praised for their efficiency, innovative technologies, and robust features that cater to various construction needs.

The Multiquip M4870300104B is a powerful multi-process welder, designed to tackle a wide variety of welding applications. This model is equipped with an advanced inverter technology that allows it to deliver smooth and stable arcs for TIG, MIG, and Stick welding. The inverter design also enhances energy efficiency, making it an ideal choice for both on-site and workshop use. Furthermore, the M4870300104B features a dual-voltage capability, supporting both 120V and 240V input, which provides flexibility for different job sites.

In terms of usability, the M4870300104B boasts an intuitive control panel that allows for easy adjustments. Its lightweight design ensures easy transport, while the rugged construction promises durability in demanding environments. With a duty cycle of 35% at 200 Amps, this welder is built for efficiency and long-lasting performance, making it suitable for both professional and DIY applications.

On the other hand, the C1870300404 is a high-performance concrete vibratory screed that plays a crucial role in ensuring smooth finishes on concrete surfaces. This model is engineered with advanced vibration technology which allows it to efficiently remove air pockets and stabilize the concrete. The C1870300404 features a robust aluminum frame, enhancing its durability while maintaining a lightweight structure for ease of handling.

Equipped with a powerful and reliable engine, the C1870300404 offers impressive runtime, allowing crews to work continuously without frequent interruptions. It also features adjustable vibration settings, enabling users to customize the intensity based on the specific requirements of the project at hand. The ergonomic design of the handle contributes to user comfort, reducing fatigue during extended periods of operation.

In conclusion, both the Multiquip M4870300104B and C1870300404 exemplify the brand’s commitment to quality, innovation, and user-centric design. These tools not only enhance productivity but also guarantee precision and efficiency in various construction tasks. Whether for welding or concrete finishing, Multiquip continues to deliver equipment that meets the evolving demands of the industry.