Multiquip DCA125USI3CAN manual GeNeral SaFetY, Generator Safety

Page 7

Safety Information

geNeral SaFetY

CAuTiON

„Never operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

„ Never operate this equipment when not feeling well due to fatigue, illness or when under medication.

„Never operate this equipment under the infl uence of drugs or alcohol.

„alWaYS check the equipment for loosened threads or bolts before starting.

„DO NOT use the equipment for any purpose other than its intended purposes or applications.

NOTICE

„This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.

„Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.

„Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

„Never use accessories or attachments that are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

„ alWaYS know the location of the nearest fire extinguisher.

„ alWaYS know the location of the nearest first aid kit.

„alWaYS know the location of the nearest

phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

GENERATOR SAFETY

DANGER

„Never operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

WARNiNG

„Never disconnect any emergency or safety devices.

These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CAuTiON

„Never lubricate components or attempt service on a running machine.

NOTICE

„alWaYS ensure generator is on level ground before use.

„alWaYS keep the machine in proper running condition.

„Fix damage to machine and replace any broken parts immediately.

„alWaYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel

DCA125USI3CAN 60 hz Generator • operation and parts manual — rev. #2 (09/24/13) — page 7

Image 7
Contents Model DCA125USI3CAN Parts List NO. M3874400004Fuel and chemical warnings Administrator Reporting Safety DefectsNhtsa DCA125USI3CAN Generator Table of ContentsChoose from three easy options SaFetY meSSageS Safety InformationSaFetY SYmBolS Generator Safety GeNeral SaFetYRestricted. If the air fl ow is ENGiNE SafetyIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine FUel SaFetYTOWiNG Safety „ Never use fuel as a cleaning agentDeath EleCtrICal SaFetYGrounding Safety Power Cord/Cable SafetyENvIroNmeNtal SaFetY BatterY SaFetYModel Isuzu 4HK1XYGD-03 Tier SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Major Components Generator Control Panel Generator Control PanelPage Engine Operating Panel Module Fuel Gauge Indicates amount of diesel fuel availableTerminal legs O and Ground are considered bonded grounds Output Terminal FamiliarizationOutput Terminal Panel is provided with the following VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelTwist Lock Dual Voltage 120/240 VAC Receptacles Over Current Relay Connecting LoadsType of Load Single Phase LoadThree Phase Load Load ApplicationGenerator Amperage Voltage Selector SwitchVoltage Selector Switch Locking Button Generator Output VoltagesAC Ammeter Gauge Reading How to Read the ac ammeter and ac voltage gaugesGenerator OUTPUTS/gauge reading AC Voltmeter Gauge Reading3Ø-240/139 Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesFuel Check Inspection/SETUPCircuit Breakers Lubrication OilOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Place the engine speed switch in the LOW down positionBefore Starting StartingPre-Heat Lamp OFF/RESET position Normal Shutdown ProcedureEmergency Shutdown Procedure To shutdown the generator, use the following procedureGeneral Inspection Air Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAir Removal Flushing Out Radiator and Replacing Coolant Radiator CleaningCheck Oil Level Replacing Oil FilterBattery Charger & Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsNever use an pneumatic air gun to tighten wheel lug nuts Trailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramSymptom Possible Problem Solution Troubleshooting GeneratorMethod of Operation Troubleshooting Diagnostic lampPage Explanation of Code in Remarks Column To 3 units Suggested Spare PartsQty Description Generator Assy Coupling Disk Part Name QTY. RemarksField Assy FANControl box Assy Part Name QTY Remarks Push Button SwitchDiagnostic Switch Selector SwitchControl box Assy Water Temperature Gauge Switch BracketSwitch Cover Alarm LampControl box Assy Wire HARNESS, Engine SWITCH, Fuel PumpEngine and Radiator Assy BAND, AIR Cleaner AIR CleanerINDICATOR, AIR Cleaner Bracket AIR CleanerEngine and Radiator Assy Hose Joint ConnectorAIR Duct Hose Blow by HoseEngine and Radiator Assy BRACKET, FAN Shroud BRACKET, Inter CoolerCooler Hose FAN ShroudOutput Terminal Assy Output Window Terminal BoardOutput Terminal Bolt Terminal CoverBattery Assy Battery Bolt SET BatteryBattery Sheet Battery BandMuffler Assy Bolt SET MufflerExhaust Pipe GasketFuel Tank Assy Fuel Tank Bracket Fuel TankFuel Tank CAP Fuel Sender UnitEnclosure ASSY. Part Hose Cover BaseEnvironmental Tank Front FrameEnclosure ASSY. Part COVER, Radiator CAP Back PlateDuct Over COVER, Front FrameEnclosure ASSY. Part Rear Frame Enclosure ASSY. Part Side Panel Seal RubberWasher Manual PackRubber Seals Assy REMArks Nameplate and Decals Assy Decal Decal NOTICE, Load Sharing FrenchNameplate and Decals Assy Decal NOTICE, Supply Wires French Decal MQ PowerPlate MQ Power Decal NOTICE, Supply Wires EnglishFreIght polICY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help