DCA-150SSKII — OUTPUTTERMINAL PANEL OVERVIEW

OUTPUT TERMINAL PANEL FAMILIARIZATION

The “Output Terminal Panel” is provided with the following:

"Three 240/139V output receptacles, 50 amp

"Two 120V input receptacles, 20 amp

"3 Load Circuit Breakers 265V @65 amps

"2 Load GFCI Circuit Breakers 265V@ 20amps

Control Box

The “Control Box” is provided with the following:

"Main Circuit Breaker 400 amps

"Over-Current Relay

Output Terminal Panel

The Output Control Panel (See Figure 14) is located on the right hand side (left from control panel) of the generator. The UNV lugs are protected by a face plate cover that can be secured in the close position by a pad lock. (See Figure 11).

FIGURE 11. Output Terminal Cover

120 Volt Recetacle

Two GFCI Duplex Nema 5-20R (120V, 20 Amp) recepacle is provided on the output terminal. This receptacle can be used anytime the generator is in operation. The receptacle is controlled by the circuit breaker located on the control panel.

Pressing the reset button resets the receptacle after being tripped. Pressing the "Test Button" (See Figure 12) in the center of this receptacle will check the GFCI function. The receptacle should be tested at least once a month.

Connecting Load

Loads can be connected to the generator by the UNV Lugs or the convienience receptacles. (See figure 13). Make sure to read the operation manual before attempting to connect a load to the generator.

FIGURE 13. Connecting Load

Circuit Breakers

To protect the generator from an overload, a 3-pole, 400 amp, main circuit breaker is provided to protect the UNV output terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload.Three 50 amp load circuit breakers have also been provided to protect the load side of the generator from overload. Make sure to switch ALL circuit breakers to the "OFF" position prior to starting the engine.

Maximum Output

The entire load connected to the UNV Lugs, all four slots in the duplex receptacles, and the must not exceed 132 kW in standby or 120 kW in prime output.

Twist Lock Dual Voltage Receptacles - To use these receptacles, place the voltage selector switch in the single phase 240/120 voltage position and adjust the output voltage to 240 volts with the voltage regulator on the Control Panel (see figure 14). Place the voltmeter change- over switch to the U-W positon and the ammeter change- over switch to the U or W to read the output.

FIGURE 12. GFCI Test Button

PAGE 32 —DCA-150SSKII— PARTS AND OPERATION MANUAL — REV. #2 (05/08/01)

Image 32
Contents MQ Power Model DCA-150SSKII Portable Generator Table of Contents Heres HOW to GET Help Table of Contents Parts Ordering Procedures USAGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneEmergencies Maintenance SafetyTransporting Towing Safety Precautions DCA-150SSKII TowingDCA-150SSKII -TRAILER-SAFETY Guidelines Explanation of ChartDCA-150SSKII -TRAILER-SPECIFICATIONS TRLR-10XFDCA-150SSKII -TRAILER-SPECIFICATIONS ElectricalElectric Brake Adjustment DCA-150SSKII -TRAILER Braking SystemBrakes Electric BrakesDCA-150SSKII -TRAILER Braking System Hydraulic/Air/Surge BrakesDCA-150SSKII -TRAILER Tires & Suspension Tires/Wheels/Lug NutsTire Wear/Inflation SuspensionDCA-150SSKII -TRAILERTIRES & Suspension Lug Nut Torque RequirementsDCA-150SSKII Trailer Wiring Diagrams DCA-150SSKII TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-150SSKII -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-150SSKII Operation and Safety Decals Machine Safety DecalsDCA-150SSKII Operation and Safety Decals DCA-150SSKII Specifications Generator SpecificationsDCA-150SSKII General Information Page DCA-150SSKII Major Components Major ComponentsDCA-150SSKII Dimensions TOP, SIDE, and Rear DimensionsDCA-150SSKII Control Panel Control PanelDCA-150SSKII Control Panel Mpec ModuleDCA-150SSKII Engine Operating Panel Engine Operating PanelDCA150SSKII Engine Operating Panel Connecting Load DCA-150SSKII Outputterminal Panel OverviewVolt Recetacle Circuit BreakersDCA-150SSKII Outputterminal Panel Overview Voltage Selector Switch Voltage Selector Switch Locking ButtonOutput Terminal Panel Available Voltages Maximum AmpsHow to read the output terminal guages Output on the selected leg240/120V Hard Wire Hookup 480/240V Hard Wire HookupSingle Phase 277V, 254V, or Single Phase 480V, 440V, or 416 VoltPhase, 480V, 440V, or 416 Volt Single Phase 139V, 127V, or Single Phase 240V, 220V, or 208 VoltPhase, 240V, 220V, or 208 Volt Single Phase, 240 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase 120 Volt Indoor Installation DCA-150SSKII InstallationOutdoor Installation DCA-150SSKII Installation Typical Generator Grounding ApplicationExtension Cable DCA-150SSKII PRE-SETUPGeneral Inspection Prior to Operation DCA-150SSKII PRE-SETUP Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Piping and Hose Connection Battery Cable InstallationWiring DCA-150SSKII Load Application Single Phase LoadThree Phase Load Before Starting Before Starting Generator and Control PanelClose all engine enclosure doors Figure Voltage Meter Volts DCA-150SSKII Generator START-UP Procedure Auto DCA-150SSKII Generator SHUT-DOWN Procedure Engine ShutdownDCA-150SSKII Maintenance DCA-150SSKII Maintenance Inspection / MaintenanceDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING GENERATOR/ENGINE Engine & Generator TroubleshootingDCA-150SSKII -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnQty Description DCA-150SSKII- Generator Assy Generator AssyDCA-150SSKII- Generator Assy DCA-150SSKII Control BOX Assy Control BOX AssyDCA-150SSKII Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator AssyDCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator ASSY.Hose Band HoseDCA-150SSKII Engine Operating Panel Assy Engine Operating Panel AssyEngine Operating PanelTable of Contents DCA-150SSKII Engine Operating Panel Assy Engine Operating Panel DCA-150SSKII Battery Assy Battery AssyDCA-150SSKII Battery Assy DCA-150SSKII Muffler Assy Muffler AssyDCA-150SSKII Muffler Assy MufflerExhaust Pipe SheetDCA-150SSKII Fueltank Assy Fuel Tank AssyDCA-150SSKII Fueltank Assy DCA-150SSKII Enclosure Assy Enclosure AssyDCA-150SSKII Enclosure Assy Cato Gold DCA-150SSKII Enclosure Assy DCA-150SSKII Rubber Seals Assy Rubber Seals AssyRubber Seals DCA-150SSKII Rubber Seals AssyDCA-150SSKII Name Plate and Decals Name Plate and DecalsDCA-150SSKII Name Plate and Decals DCA-150SSKII Name Plate and Decals Battery Group Muffler GroupFuel Tank Group Enclosure GroupEffective July 1 Page 800/421-1244 or 310/537-3700 FAX 310

DCA-150SSKII specifications

The Multiquip DCA-150SSKII is a robust and reliable 150kVA diesel generator designed to meet the demands of various applications, particularly in construction, events, and industrial settings. Engineered for high performance and durability, this generator stands out with its advanced features, technologies, and characteristics.

One of the primary features of the DCA-150SSKII is its powerful Yanmar diesel engine. This engine is renowned for its exceptional fuel efficiency and reliability, ensuring that the generator can run for extended periods without the need for frequent refueling. The engine is designed to meet stringent emissions standards, making the DCA-150SSKII an environmentally friendly option for those needing portable power solutions.

The generator is equipped with a state-of-the-art digital control panel that simplifies the operation and monitoring of the unit. The control panel provides real-time data about the generator's performance, including voltage, frequency, and operational hours, allowing users to efficiently manage power distribution. Additionally, the generator features an automatic voltage regulator that ensures stable and consistent power output, crucial for sensitive electronics and equipment.

The DCA-150SSKII is designed with durability in mind. Its sturdy frame and weather-resistant enclosure protect it from the elements, making it suitable for outdoor use in a variety of conditions. Noise reduction technology is integrated into the design, ensuring that the generator operates quietly, which is particularly beneficial for urban settings or nighttime operations.

Safety is paramount in the design of the DCA-150SSKII. It includes essential safety features such as low oil pressure shutdown, high-temperature shutdown, and overload protection. These features help prevent damage to the generator and ensure safe operation in various environments.

Mobility is another characteristic that sets the DCA-150SSKII apart. It is equipped with a robust chassis and lifting hooks, making it easy to transport from one location to another, whether on a job site or for an event.

In summary, the Multiquip DCA-150SSKII combines power, efficiency, and reliability in a compact design. Its advanced technological features, durability, and safety mechanisms make it an excellent choice for anyone in need of a dependable diesel generator. With its powerful performance and user-friendly operation, the DCA-150SSKII is a top contender in the generator market, meeting the diverse power needs of professionals across various industries.