Outdoor Installation

Install the generator in a location where it will not be exposed to rain or sunshine. Make sure that the generator is on secure level ground so it cannot slide or shift around. Also install the generator so the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear, not only to the engine parts, but also to the alternator parts.

CAUTION :

Pay close attention to ventilation when operating the generator inside tunnels and caves. The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

Indoor Installation

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside.The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

DO NOT cover ventilation areas on the enclosure, covering the ventilation grids will cause the engine to over heat.

Table of Contents

DCA-150SSKII — INSTALLATION

CAUTION :

An electric shock is apt to happen when vibrators are used. Pay close attention to handling when operating vibrators and always use rubber boots and gloves to insulate the body from electrical shock.

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generator (Figure 9) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried a minimum of 8 ft. into the ground.

NOTE

When connecting the generator to any buildings electrical system ALWAYS consult with a licensed electrician.

PAGE 40 —DCA-150SSKII— PARTS AND OPERATION MANUAL — REV. #2 (05/08/01)

Image 40
Contents MQ Power Model DCA-150SSKII Portable Generator Table of Contents Heres HOW to GET Help Table of Contents Parts Ordering Procedures USAGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneTransporting Maintenance SafetyEmergencies Towing Safety Precautions DCA-150SSKII TowingDCA-150SSKII -TRAILER-SAFETY Guidelines Explanation of ChartDCA-150SSKII -TRAILER-SPECIFICATIONS TRLR-10XFDCA-150SSKII -TRAILER-SPECIFICATIONS ElectricalElectric Brake Adjustment DCA-150SSKII -TRAILER Braking SystemBrakes Electric BrakesDCA-150SSKII -TRAILER Braking System Hydraulic/Air/Surge BrakesDCA-150SSKII -TRAILER Tires & Suspension Tires/Wheels/Lug NutsTire Wear/Inflation SuspensionDCA-150SSKII -TRAILERTIRES & Suspension Lug Nut Torque RequirementsDCA-150SSKII Trailer Wiring Diagrams DCA-150SSKII TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-150SSKII -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-150SSKII Operation and Safety Decals Machine Safety DecalsDCA-150SSKII Operation and Safety Decals DCA-150SSKII Specifications Generator SpecificationsDCA-150SSKII General Information Page DCA-150SSKII Major Components Major ComponentsDCA-150SSKII Dimensions TOP, SIDE, and Rear DimensionsDCA-150SSKII Control Panel Control PanelDCA-150SSKII Control Panel Mpec ModuleDCA-150SSKII Engine Operating Panel Engine Operating PanelDCA150SSKII Engine Operating Panel Connecting Load DCA-150SSKII Outputterminal Panel OverviewVolt Recetacle Circuit BreakersDCA-150SSKII Outputterminal Panel Overview Voltage Selector Switch Voltage Selector Switch Locking ButtonOutput Terminal Panel Available Voltages Maximum AmpsHow to read the output terminal guages Output on the selected leg240/120V Hard Wire Hookup 480/240V Hard Wire HookupPhase, 480V, 440V, or 416 Volt Single Phase 480V, 440V, or 416 VoltSingle Phase 277V, 254V, or Phase, 240V, 220V, or 208 Volt Single Phase 240V, 220V, or 208 VoltSingle Phase 139V, 127V, or Single Phase 120 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase, 240 Volt Outdoor Installation DCA-150SSKII InstallationIndoor Installation DCA-150SSKII Installation Typical Generator Grounding ApplicationGeneral Inspection Prior to Operation DCA-150SSKII PRE-SETUPExtension Cable DCA-150SSKII PRE-SETUP Air Cleaner Fan Belt Tension Cleaning the RadiatorOperation in Freezing Weather Wiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadDCA-150SSKII Load Application Before Starting Before Starting Generator and Control PanelClose all engine enclosure doors Figure Voltage Meter Volts DCA-150SSKII Generator START-UP Procedure Auto DCA-150SSKII Generator SHUT-DOWN Procedure Engine ShutdownDCA-150SSKII Maintenance DCA-150SSKII Maintenance Inspection / MaintenanceDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING GENERATOR/ENGINE Engine & Generator TroubleshootingDCA-150SSKII -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnQty Description DCA-150SSKII- Generator Assy Generator AssyDCA-150SSKII- Generator Assy DCA-150SSKII Control BOX Assy Control BOX AssyDCA-150SSKII Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator AssyDCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator ASSY.Hose Band HoseDCA-150SSKII Engine Operating Panel Assy Engine Operating Panel AssyEngine Operating PanelTable of Contents DCA-150SSKII Engine Operating Panel Assy Engine Operating Panel DCA-150SSKII Battery Assy Battery AssyDCA-150SSKII Battery Assy DCA-150SSKII Muffler Assy Muffler AssyDCA-150SSKII Muffler Assy MufflerExhaust Pipe SheetDCA-150SSKII Fueltank Assy Fuel Tank AssyDCA-150SSKII Fueltank Assy DCA-150SSKII Enclosure Assy Enclosure AssyDCA-150SSKII Enclosure Assy Cato Gold DCA-150SSKII Enclosure Assy DCA-150SSKII Rubber Seals Assy Rubber Seals AssyRubber Seals DCA-150SSKII Rubber Seals AssyDCA-150SSKII Name Plate and Decals Name Plate and DecalsDCA-150SSKII Name Plate and Decals DCA-150SSKII Name Plate and Decals Battery Group Muffler GroupFuel Tank Group Enclosure GroupEffective July 1 Page 800/421-1244 or 310/537-3700 FAX 310

DCA-150SSKII specifications

The Multiquip DCA-150SSKII is a robust and reliable 150kVA diesel generator designed to meet the demands of various applications, particularly in construction, events, and industrial settings. Engineered for high performance and durability, this generator stands out with its advanced features, technologies, and characteristics.

One of the primary features of the DCA-150SSKII is its powerful Yanmar diesel engine. This engine is renowned for its exceptional fuel efficiency and reliability, ensuring that the generator can run for extended periods without the need for frequent refueling. The engine is designed to meet stringent emissions standards, making the DCA-150SSKII an environmentally friendly option for those needing portable power solutions.

The generator is equipped with a state-of-the-art digital control panel that simplifies the operation and monitoring of the unit. The control panel provides real-time data about the generator's performance, including voltage, frequency, and operational hours, allowing users to efficiently manage power distribution. Additionally, the generator features an automatic voltage regulator that ensures stable and consistent power output, crucial for sensitive electronics and equipment.

The DCA-150SSKII is designed with durability in mind. Its sturdy frame and weather-resistant enclosure protect it from the elements, making it suitable for outdoor use in a variety of conditions. Noise reduction technology is integrated into the design, ensuring that the generator operates quietly, which is particularly beneficial for urban settings or nighttime operations.

Safety is paramount in the design of the DCA-150SSKII. It includes essential safety features such as low oil pressure shutdown, high-temperature shutdown, and overload protection. These features help prevent damage to the generator and ensure safe operation in various environments.

Mobility is another characteristic that sets the DCA-150SSKII apart. It is equipped with a robust chassis and lifting hooks, making it easy to transport from one location to another, whether on a job site or for an event.

In summary, the Multiquip DCA-150SSKII combines power, efficiency, and reliability in a compact design. Its advanced technological features, durability, and safety mechanisms make it an excellent choice for anyone in need of a dependable diesel generator. With its powerful performance and user-friendly operation, the DCA-150SSKII is a top contender in the generator market, meeting the diverse power needs of professionals across various industries.