Multiquip DCA-150SSKII operation manual Cleaning the Radiator, Air Cleaner Fan Belt Tension

Page 44

CAUTION :

When adding coolant or antifreeze to the radiator, do not remove the radiator cap until the unit has completely cooled.

Day-to-day addition of coolant is done from the reserve tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table

13.for engine, radiator, and reserve tank coolant capacities. Make sure that the coolant level in the reserve tank is always between the "H" and the "L" markings.

Table of Contents

DCA-150SSKIIPRE-SETUP

Cleaning the Radiator

The radiator may overheat if the fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the battery disconnected.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the Komatsu Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

Komatsu Engine Owner's Manual.

Table 13. Coolant Capacity

Engine and Radiator

7.4 Gal. (28 Liters)

 

 

Reserve Tank

2 Quarts (11.9 Liters)

 

 

Operation in Freezing Weather

When operating in freezing weather, be certain that the proper amount of antifreeze (Table 14) has been added.

Table 14. Anti-Freeze Operating Temperatures

Vol %

Freezing Point

Boiling Point

 

 

 

 

Anti-Fre-

 

 

 

 

 

 

 

 

eze

°C

°F

°C

°F

 

 

 

 

 

 

40

-24

-12

106

222

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTE

When the anti-freeze is mixed with water, the anti-freeze mixing ratio must be less than 50%.

The fan belt tension is proper if the fan belt bends 7 to 10

mm(Figure 40) when depressed with the thumb as shown below.

Figure 40. Fan Belt Tension

CAUTION :

Never place hands near the belts or fan while the generator set is running.

Battery

This unit is of negative ground. DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level is not properly maintained. Add only distilled water when replenishment is necessary.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68°F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with a thin film of grease will help to inhibit corrosion.

PAGE 44 —DCA-150SSKII— PARTS AND OPERATION MANUAL — REV. #2 (05/08/01)

Image 44
Contents MQ Power Model DCA-150SSKII Portable Generator Table of Contents Heres HOW to GET Help Table of Contents Parts Ordering Procedures USAGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneEmergencies Maintenance SafetyTransporting Towing Safety Precautions DCA-150SSKII TowingDCA-150SSKII -TRAILER-SAFETY Guidelines Explanation of ChartDCA-150SSKII -TRAILER-SPECIFICATIONS TRLR-10XFDCA-150SSKII -TRAILER-SPECIFICATIONS ElectricalElectric Brake Adjustment DCA-150SSKII -TRAILER Braking SystemBrakes Electric BrakesDCA-150SSKII -TRAILER Braking System Hydraulic/Air/Surge BrakesDCA-150SSKII -TRAILER Tires & Suspension Tires/Wheels/Lug NutsTire Wear/Inflation SuspensionDCA-150SSKII -TRAILERTIRES & Suspension Lug Nut Torque RequirementsDCA-150SSKII Trailer Wiring Diagrams DCA-150SSKII TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-150SSKII -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-150SSKII Operation and Safety Decals Machine Safety DecalsDCA-150SSKII Operation and Safety Decals DCA-150SSKII Specifications Generator SpecificationsDCA-150SSKII General Information Page DCA-150SSKII Major Components Major ComponentsDCA-150SSKII Dimensions TOP, SIDE, and Rear DimensionsDCA-150SSKII Control Panel Control PanelDCA-150SSKII Control Panel Mpec ModuleDCA-150SSKII Engine Operating Panel Engine Operating PanelDCA150SSKII Engine Operating Panel Connecting Load DCA-150SSKII Outputterminal Panel OverviewVolt Recetacle Circuit BreakersDCA-150SSKII Outputterminal Panel Overview Voltage Selector Switch Voltage Selector Switch Locking ButtonOutput Terminal Panel Available Voltages Maximum AmpsHow to read the output terminal guages Output on the selected leg240/120V Hard Wire Hookup 480/240V Hard Wire HookupSingle Phase 277V, 254V, or Single Phase 480V, 440V, or 416 VoltPhase, 480V, 440V, or 416 Volt Single Phase 139V, 127V, or Single Phase 240V, 220V, or 208 VoltPhase, 240V, 220V, or 208 Volt Single Phase, 240 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase 120 Volt Indoor Installation DCA-150SSKII InstallationOutdoor Installation DCA-150SSKII Installation Typical Generator Grounding ApplicationExtension Cable DCA-150SSKII PRE-SETUPGeneral Inspection Prior to Operation DCA-150SSKII PRE-SETUP Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Piping and Hose Connection Battery Cable InstallationWiring DCA-150SSKII Load Application Single Phase LoadThree Phase Load Before Starting Before Starting Generator and Control PanelClose all engine enclosure doors Figure Voltage Meter Volts DCA-150SSKII Generator START-UP Procedure Auto DCA-150SSKII Generator SHUT-DOWN Procedure Engine ShutdownDCA-150SSKII Maintenance DCA-150SSKII Maintenance Inspection / MaintenanceDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING Engine Engine TroubleshootingDCA-150SSKII -TROUBLESHOOTING GENERATOR/ENGINE Engine & Generator TroubleshootingDCA-150SSKII -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnQty Description DCA-150SSKII- Generator Assy Generator AssyDCA-150SSKII- Generator Assy DCA-150SSKII Control BOX Assy Control BOX AssyDCA-150SSKII Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator AssyDCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy Engine & Radiator ASSY.Hose Band HoseDCA-150SSKII Engine Operating Panel Assy Engine Operating Panel AssyEngine Operating PanelTable of Contents DCA-150SSKII Engine Operating Panel Assy Engine Operating Panel DCA-150SSKII Battery Assy Battery AssyDCA-150SSKII Battery Assy DCA-150SSKII Muffler Assy Muffler AssyDCA-150SSKII Muffler Assy MufflerExhaust Pipe SheetDCA-150SSKII Fueltank Assy Fuel Tank AssyDCA-150SSKII Fueltank Assy DCA-150SSKII Enclosure Assy Enclosure AssyDCA-150SSKII Enclosure Assy Cato Gold DCA-150SSKII Enclosure Assy DCA-150SSKII Rubber Seals Assy Rubber Seals AssyRubber Seals DCA-150SSKII Rubber Seals AssyDCA-150SSKII Name Plate and Decals Name Plate and DecalsDCA-150SSKII Name Plate and Decals DCA-150SSKII Name Plate and Decals Battery Group Muffler GroupFuel Tank Group Enclosure GroupEffective July 1 Page 800/421-1244 or 310/537-3700 FAX 310

DCA-150SSKII specifications

The Multiquip DCA-150SSKII is a robust and reliable 150kVA diesel generator designed to meet the demands of various applications, particularly in construction, events, and industrial settings. Engineered for high performance and durability, this generator stands out with its advanced features, technologies, and characteristics.

One of the primary features of the DCA-150SSKII is its powerful Yanmar diesel engine. This engine is renowned for its exceptional fuel efficiency and reliability, ensuring that the generator can run for extended periods without the need for frequent refueling. The engine is designed to meet stringent emissions standards, making the DCA-150SSKII an environmentally friendly option for those needing portable power solutions.

The generator is equipped with a state-of-the-art digital control panel that simplifies the operation and monitoring of the unit. The control panel provides real-time data about the generator's performance, including voltage, frequency, and operational hours, allowing users to efficiently manage power distribution. Additionally, the generator features an automatic voltage regulator that ensures stable and consistent power output, crucial for sensitive electronics and equipment.

The DCA-150SSKII is designed with durability in mind. Its sturdy frame and weather-resistant enclosure protect it from the elements, making it suitable for outdoor use in a variety of conditions. Noise reduction technology is integrated into the design, ensuring that the generator operates quietly, which is particularly beneficial for urban settings or nighttime operations.

Safety is paramount in the design of the DCA-150SSKII. It includes essential safety features such as low oil pressure shutdown, high-temperature shutdown, and overload protection. These features help prevent damage to the generator and ensure safe operation in various environments.

Mobility is another characteristic that sets the DCA-150SSKII apart. It is equipped with a robust chassis and lifting hooks, making it easy to transport from one location to another, whether on a job site or for an event.

In summary, the Multiquip DCA-150SSKII combines power, efficiency, and reliability in a compact design. Its advanced technological features, durability, and safety mechanisms make it an excellent choice for anyone in need of a dependable diesel generator. With its powerful performance and user-friendly operation, the DCA-150SSKII is a top contender in the generator market, meeting the diverse power needs of professionals across various industries.