Multiquip operation manual DCA-150SSKII PRE-SETUP

Page 43

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but do not overfill. Make sure the generator is level. With the dipstick inserted all the way, but without being screw into the filler hole, verify that the oil level is maintained between the two notches (Figure 39) on the dipstick. See Table 3 for proper selection of engine oil.

Figure 39. Engine Oil Dipstick

Table of Contents

DCA-150SSKIIPRE-SETUP

Fuel

Fill the fuel tank with clean and fresh diesel fuel. DO NOT fill the tank beyond capacity.

Pay attention to the fuel tank capacity when replenishing fuel. Refer to the fuel tank capacity listed on page 23, Specification Table 7.

The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

CAUTION:Never fill the fuel tank while the engine is running or in the dark. Diesel spillage on a hot engine can cause a fire or explosion. If diesel spillage occurs, wipe up the spilled diesel completely to prevent fire hazards.

Coolant

Use only drinkable tap water. If hard water or water with many impurities is used, the inside of the engine and radiator may become coated with deposits and cooling efficiency will be reduced.

When checking the engine oil, be sure to check if the oil is clean and viscous. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Komatsu Engine Owner's Manual.

An anticorrosion additive added to the water will help prevent deposits and corrosion in the cooling system. See the engine manual for further details.

Table 12. Recommended Motor Oil

Temperature

Type Oil

Range

 

 

 

104° F ~ 23° F

SAE 30

(40° C ~ -5°C)

 

 

 

23° F ~ 5° F

SAE 20 or SAE 10W-30

(-5° C ~ -15°C)

 

Below 5° C (-15°)

SAE 10W or SAE 10W-30

DCA-150SSKII — PARTS AND OPERATION MANUAL— REV. #1 (05/08/01) — PAGE 43

Image 43
Contents MQ Power Model DCA-150SSKII Portable Generator Table of Contents Heres HOW to GET Help Table of Contents USA Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryTransporting Maintenance SafetyEmergencies DCA-150SSKII Towing Towing Safety PrecautionsExplanation of Chart DCA-150SSKII -TRAILER-SAFETY GuidelinesTRLR-10XF DCA-150SSKII -TRAILER-SPECIFICATIONSElectrical DCA-150SSKII -TRAILER-SPECIFICATIONSElectric Brakes Electric Brake AdjustmentDCA-150SSKII -TRAILER Braking System BrakesHydraulic/Air/Surge Brakes DCA-150SSKII -TRAILER Braking SystemSuspension DCA-150SSKII -TRAILER Tires & SuspensionTires/Wheels/Lug Nuts Tire Wear/InflationLug Nut Torque Requirements DCA-150SSKII -TRAILERTIRES & SuspensionDCA-150SSKII Trailer Wiring Diagrams Electric Brake Troubleshooting DCA-150SSKII TRAILER-BRAKETROUBLESHOOTINGHydraulic Brake Troubleshooting DCA-150SSKII -TRAILER-BRAKETROUBLESHOOTINGMachine Safety Decals DCA-150SSKII Operation and Safety DecalsDCA-150SSKII Operation and Safety Decals Generator Specifications DCA-150SSKII SpecificationsDCA-150SSKII General Information Page Major Components DCA-150SSKII Major ComponentsDimensions DCA-150SSKII Dimensions TOP, SIDE, and RearControl Panel DCA-150SSKII Control PanelMpec Module DCA-150SSKII Control PanelEngine Operating Panel DCA-150SSKII Engine Operating PanelDCA150SSKII Engine Operating Panel Circuit Breakers Connecting LoadDCA-150SSKII Outputterminal Panel Overview Volt RecetacleDCA-150SSKII Outputterminal Panel Overview Maximum Amps Voltage Selector SwitchVoltage Selector Switch Locking Button Output Terminal Panel Available VoltagesOutput on the selected leg How to read the output terminal guages480/240V Hard Wire Hookup 240/120V Hard Wire HookupPhase, 480V, 440V, or 416 Volt Single Phase 480V, 440V, or 416 VoltSingle Phase 277V, 254V, or Phase, 240V, 220V, or 208 Volt Single Phase 240V, 220V, or 208 VoltSingle Phase 139V, 127V, or Single Phase 120 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase, 240 Volt Outdoor Installation DCA-150SSKII InstallationIndoor Installation Typical Generator Grounding Application DCA-150SSKII InstallationGeneral Inspection Prior to Operation DCA-150SSKII PRE-SETUPExtension Cable DCA-150SSKII PRE-SETUP Air Cleaner Fan Belt Tension Cleaning the RadiatorOperation in Freezing Weather Wiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadDCA-150SSKII Load Application Before Starting Generator and Control Panel Before StartingClose all engine enclosure doors Figure Voltage Meter Volts DCA-150SSKII Generator START-UP Procedure Auto Engine Shutdown DCA-150SSKII Generator SHUT-DOWN ProcedureDCA-150SSKII Maintenance Inspection / Maintenance DCA-150SSKII MaintenanceEngine Troubleshooting DCA-150SSKII -TROUBLESHOOTING EngineEngine Troubleshooting DCA-150SSKII -TROUBLESHOOTING EngineEngine & Generator Troubleshooting DCA-150SSKII -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-150SSKII -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description Generator Assy DCA-150SSKII- Generator AssyDCA-150SSKII- Generator Assy Control BOX Assy DCA-150SSKII Control BOX AssyDCA-150SSKII Control BOX Assy DCA-150SSKII- Control BOX Assy DCA-150SSKII- Control BOX Assy Engine & Radiator Assy DCA-150SSKII- Engine & Radiator AssyDCA-150SSKII- Engine & Radiator Assy DCA-150SSKII- Engine & Radiator Assy Hose DCA-150SSKII- Engine & Radiator AssyEngine & Radiator ASSY. Hose BandEngine Operating Panel Assy DCA-150SSKII Engine Operating Panel AssyEngine Operating PanelTable of Contents DCA-150SSKII Engine Operating Panel Assy Engine Operating Panel Battery Assy DCA-150SSKII Battery AssyDCA-150SSKII Battery Assy Muffler Assy DCA-150SSKII Muffler AssySheet DCA-150SSKII Muffler AssyMuffler Exhaust PipeFuel Tank Assy DCA-150SSKII Fueltank AssyDCA-150SSKII Fueltank Assy Enclosure Assy DCA-150SSKII Enclosure AssyDCA-150SSKII Enclosure Assy Cato Gold DCA-150SSKII Enclosure Assy Rubber Seals Assy DCA-150SSKII Rubber Seals AssyDCA-150SSKII Rubber Seals Assy Rubber SealsName Plate and Decals DCA-150SSKII Name Plate and DecalsDCA-150SSKII Name Plate and Decals DCA-150SSKII Name Plate and Decals Enclosure Group Battery GroupMuffler Group Fuel Tank GroupEffective July 1 Page 800/421-1244 or 310/537-3700 FAX 310

DCA-150SSKII specifications

The Multiquip DCA-150SSKII is a robust and reliable 150kVA diesel generator designed to meet the demands of various applications, particularly in construction, events, and industrial settings. Engineered for high performance and durability, this generator stands out with its advanced features, technologies, and characteristics.

One of the primary features of the DCA-150SSKII is its powerful Yanmar diesel engine. This engine is renowned for its exceptional fuel efficiency and reliability, ensuring that the generator can run for extended periods without the need for frequent refueling. The engine is designed to meet stringent emissions standards, making the DCA-150SSKII an environmentally friendly option for those needing portable power solutions.

The generator is equipped with a state-of-the-art digital control panel that simplifies the operation and monitoring of the unit. The control panel provides real-time data about the generator's performance, including voltage, frequency, and operational hours, allowing users to efficiently manage power distribution. Additionally, the generator features an automatic voltage regulator that ensures stable and consistent power output, crucial for sensitive electronics and equipment.

The DCA-150SSKII is designed with durability in mind. Its sturdy frame and weather-resistant enclosure protect it from the elements, making it suitable for outdoor use in a variety of conditions. Noise reduction technology is integrated into the design, ensuring that the generator operates quietly, which is particularly beneficial for urban settings or nighttime operations.

Safety is paramount in the design of the DCA-150SSKII. It includes essential safety features such as low oil pressure shutdown, high-temperature shutdown, and overload protection. These features help prevent damage to the generator and ensure safe operation in various environments.

Mobility is another characteristic that sets the DCA-150SSKII apart. It is equipped with a robust chassis and lifting hooks, making it easy to transport from one location to another, whether on a job site or for an event.

In summary, the Multiquip DCA-150SSKII combines power, efficiency, and reliability in a compact design. Its advanced technological features, durability, and safety mechanisms make it an excellent choice for anyone in need of a dependable diesel generator. With its powerful performance and user-friendly operation, the DCA-150SSKII is a top contender in the generator market, meeting the diverse power needs of professionals across various industries.