Kohler 116347-2 manual Wiring Connections, Suction Assembly

Page 4

WIRING CONNECTIONS

WARNING: Risk of electrical shockTo ￿ reduce the risk of electric shock￿ connect only to a properly grounded￿ grounding:type receptacle￿ protected by a ￿round:￿ault Circuit:Interrupter ￿￿￿CI￿￿ Do not remove the plug￿s grounding pin￿ Do not use a grounding adapter￿

The Kohler Custom BodySpa is equipped with a cord and plug￿ All wiring of the pump has been completed at the factory￿ A licensed electrician

will need to install a ￿￿CI:protected￿ 120 V￿ 20 A￿ grounded outlet￿ The electrician must install the outlet behind the BodySpa￿ and within 24:inches

of the pump￿ No other load should be on this circuit￿

SUCTION ASSEMBLY

DESIGN GUIDE

The purpose of the suction bracket is to position the suction housing at the correct installation height￿

and to provide the installer with a means of securing the suction housing in place during final assembly￿ Do not remove the suction fitting from the

bracket

assembly￿

 

 

 

 

 

 

 

 

 

 

 

 

You can locate the suction along any wall of the

 

Custom BodySpa room within 48:inches of the

 

 

pump box￿ as long as

the

overall

wall

thickness

will

not

exceed

1:3/4:inches￿

Plan

to

provide

 

access

to

 

the

suction

assembly in

case

servicing

is

needed￿

 

The suction location must allow the installer

to

 

route straight lengths of 1:1/2:inch ￿I￿D￿￿ rigid PVC

tubing￿ with no vertical

elbows

inline

to

trap

water￿

from the suction housing to

 

the

pump

 

inlet￿

You

can

use

a

90:degree

elbow

at

a

wall corner

 

if the suction

is

located

on a

different

wall

than

the

 

pump

box￿

NOTE: Refer to the minimum waterline height information on the side of the pump box to determine the maximum pump box height needed for the pump to prime effectively￿

Plan to apply a minimum 1/4:inch per foot pitch toward the suction housing to provide adequate water drainage through the suction line￿

116347:2:AA ￿A￿

5

Kohler Co￿￿ Kohler￿ WI

Image 4
Contents EI IE Provide Sufficient Access Design GuideTower and System Room SizeWATER%FREE Zone Pump BOXWiring Connections Suction AssemblyRain Loation Esin UIEWaterproofin Material Cement Board WATER*RESISTANT Wall MaterialFinished Wall Material Keypad Control LocationFootbath Basin Primary Heat Source Auxiliary Heat SourcesFaucets and Fittings Project Requirement SummaryInstallation Custom Bodyspa Installation InstructionsFetures Eetri RequireetsIallai Install Pump BOX Install Tower Mounting FramePlumbing Preparation Install the Variable Flow Valve Assembly Install the Suction Bracket Solvent Weld Tubing Make Electrical ConnectionsInstall Cable with Outlet BOX Install Cable Without Outlet BOXInstall Waterproofing Membrane or Compound Install Suction BushingInstall WATER0RESISTANT Wall Material Install Cement BoardConstruct Footbath Basin Strut Fiise SI, WS, EII DAI IA E D ECEInstall the Tower Install the Keypad CLEAN/UP After Installation Water Test the SystemTroubleshooting Symptoms Probable Causes Corrective ActionUsers Information Custom Bodyspa Users InformationUsers InformationLets GET Started Care and Cleaning of Your Custom Bodyspa Service and Warranty Information Page Publication No AA2 a E 1999 Kohler Co., Kohler, WI