INSTALLATION
Check Point #6
-GFCI8protected electrical power supplied to pump box (120 V, 20 A).
-Keypad cable installed and connected to the control box,
-With outlet box, or
-Without outlet box.
INSTALL WATERPROOFING
MEMBRANE OR COMPOUND
WARNING: Risk of property damage and concealed leakage. To achieve a watertight BodySpa installation it is critical that you install the waterproofing membrane or applied compound according to the material manufacturers instructions Kohler Co will not be liable for damage caused by waterproofing materials that are improperly installed or sealed
NOTE: The waterproofing membrane or applied compound and the cement board can be installed in any order you prefer as long as they are installed exactly as directed Follow all material manufacturers instructions
Install a waterproofing membrane or applied compound to thentire floor and wall surfaces up to the ceiling
Although some membranes can be installed directly
to the stud framing we suggest you install a plywood backing behind the membrane at least to the height of the basin threshold
INSTALL SUCTION BUSHING
Use a 331/43inch hole saw to carefully cut a hole in the waterproofing membrane and plywood
backing at the suction inlet location
Press the spacer fully into the suction housing inlet
Apply silicone sealant to the bushing flange surface and insert the bushing through the suction hole Partially thread the nut to the bushing Do not tighten Apply silicone sealant to the end threads of the bushing and carefully thread the bushing to the housing until hand tight Wrench tighten an additional 1/4 Doturn not overtighten. Wrench tighten the nut against the plywood backingDo not overtighten.
Remove any excess sealant
11347323AA A | 1 | Kohler Co Kohler WI |