Honeywell hw400 service manual Electrical Diagnostics HW3000/L Models

Page 34

ELECTRICAL DIAGNOSTICS (HW3000/L MODELS)

8.1 ELECTRICAL DIAGNOSTICS (HW3000/L MODELS)

General Electrical Check

Check for Tripped Duplex Circuit Breaker(s)

Outlets Above the Breaker Indicate

the Excess Load Source

Resolve Overload Problem to Ensure Safe Operation

After Electrical Load Resolved Wait Several Minutes (for Thermal Breaker to Cool) Push to Reset Breaker

If Cannot Reset, Replace Breaker

Start Engine and Run at No Load

Check Engine Frequency = 61.5 to 63 Hz

Adjust Governor, if necessary

(see Manual Section “Governor Adjustment”)

If Frequency Still Out of Range, see Engine Diagnostics Section

Check Voltage Output at NEMA 5-20R 120V

Duplex Outlet #1

W X 123-

126V G

If Voltage Out of Range,

Perform “120V Circuit #1 Check”

Check Voltage Output at NEMA 5-20R 120V

Duplex Outlet #2

W Y

123-

126V G

If Voltage Out of Range,

Perform “120V Circuit #2 Check”

120V Circuit #1 Check

(No Output OR

Voltage Out of Spec)

Conduct This Check Only When

Directed by General Electrical Check

Remove Alternator End Cover

Check Wires and Connections

from AVR to Brush Assembly

for Proper Orientation

of Wire Connections

If a Connection is Loose or Disconnected, Reestablish a Tight Connection

If a Wire or Connection is Damaged,

Replace AVR

Check Wires and Connections

for the Exciter & AVR Tap

from AVR to Alternator

On AVR Side of Connection:

If a Connection is Loose or

Disconnected, Reestablish a

Tight Connection

If a Wire or Connector is Damaged,

Replace AVR

On Alternator Side of Connection:

If a Connection is Loose or

Disconnected, Reestablish a

Tight Connection

If a Wire or Connector

is Damaged,

Replace Alternator

Check for Continuity from

Duplex Outlet #1

for Each Connection (X, Y, W, G) to Corresponding Alternator Terminal

If Continuity Not Present

in Any Circuit,

Check Wires and Connections

from Receptacle to Alternator

If a Connection is Loose or

Disconnected, Reestablish a Tight Connection and Recheck Continuity

If a Wire or Connection is Damaged,

Replace Electrical Panel

Check for Continuity in

Duplex Outlet #1 Breaker

from the Line Terminal to the Load Terminal

If No Continuity,

Replace Duplex Circuit Breaker

Check for Continuity in Each Circuit of

Duplex Outlet #1

from the Female Socket on the Front

to the Terminal on the Back

If No Continuity,

Replace Duplex Receptacle

If Continuity Present,

Replace Electrical Panel

Perform “Alternator Check”

Start Engine and Run at No Load

Check Output Voltage (X to W) of Duplex Outlet #1= 123-126V

Adjust Voltage Regulator, if Necessary by Turning the Potentiometer on the Rear of the Voltage Regulator

If Voltage Still Out of Range

Replace Voltage Regulator

120V Circuit #2 Check

(No Output OR

Voltage Out of Spec)

Conduct This Check Only When

Directed by General Electrical Check

Remove Main Control Panel from

Control Panel Assembly

Check Continuity from Duplex Outlet #1

for Each Connection (X or Y, W, G) to Duplex Outlet #2

If Continuity Not Present

in Any Circuit,

Check Wires and Connections from Duplex Outlet #1 to Duplex Outlet #2

If a Connection is Loose or Disconnected, Reestablish a Tight Connection and Recheck Continuity

If a Wire or Connection

is Damaged,

Replace Electrical Panel

Check for Continuity in

Duplex Outlet #2 Breaker

from the Line Terminal to the Load Terminal

If No Continuity,

Replace Duplex Circuit Breaker

Check for Continuity in Each Circuit of

Duplex Outlet #2

from the Female Socket on the Front

to the Terminal on the Back

If No Continuity,

Replace Duplex Receptacle

If Continuity Present,

Replace Electrical Panel

Refer to Illustrations on Pages 8-3 and 8-5.

8-2

www.honeywellgenerators.com

Honeywell Portable Electrical Generator Service Manual

Image 34
Contents Read and Save These Instructions Page Contents This page Intentionally Left Blank Safety Messages Important Safety InstructionsArds Safety Messages Electric Shock HazardsNorthshore Power Systems Consumer Limited Warranty WarrantiesWarranty Statement WarrantiesQuestions Northshore Power Systems Replacement Parts Limited Warranty Specifications and Wiring Diagrams SpecificationsBolt and Fastener Torque Information Bolt and Fastener Torque InformationWiring Diagrams Wiring DiagramsHW4000 & HW4000L HW5500 & HW5500L HW5500E & HW5500EL HW6200 & HW6200L HW7000E, HW7000EL, HW7500E, & HW7500EL Components This page Intentionally Left Blank Required Tools Preparing for ServiceTransporting Generator This page Intentionally Left Blank Service Repair Time Analysis & Flat Rate Schedule OperationService Repair Time Analysis MiscMaintenance Consumer Maintenance ScheduleConsumer Maintenance Schedule AIR Filter Maintenance AIR Filter MaintenanceTer more frequently Remove foam air filters Coat the air filter with clean engine oilSqueeze out excess oil Cleaning Fuel Sediment CUP Cleaning Fuel Sediment CUPSpark Plug Service Cleaning Spark Arrestor Screen Cleaning Spark Arrestor ScreenValve Lash Governor AdjustmentValve Lash Xtreme Battery ServiceBattery Service Yuasa 12N14-3ATroubleshooting Electrical Diagnostics HW3000/L Models Electrical Diagnostics HW3000/L ModelsAlternator Refer to Illustrations on Brush Assembly Electrical Diagnostics ALL Models Except HW3000/L Electrical Diagnostics ALL Models Except HW3000/L7000 Refer to Illustrations on AVR TAP Engine Diagnostics ALL Models Engine Diagnostics ALL ModelsControl Panel Service and DisassemblyNm 3 lb. ft Engine and Alternator See WHEEL, LEG, & Handle ASSEMBLY,Engine and Alternator Cylinder Head Bolts 48 Nm 35 lb. ftAlternator AlternatorAlso known as Automatic Voltage Regulator or AVR Fuel Tank System Fuel Tank SystemEvaporative Emissions Control System Evaporative Emissions Control SystemNm 1.5 lb. ft Muffler MufflerCarburetor CarburetorStarter Solenoid Terminal Nut 6 Nm 4 lb. ft Starting SystemStarting System Check for continuityRecoil Starter Install with recoil starter handle position as shownRecoil Starter Check for wear or damageFAN Cover Remove and install with the recoil starter assemblyInstall with the recoil starter handle position as shown FAN CoverWHEEL, LEG, & Handle Assembly WHEEL, LEG, & Handle Assembly HW3000/L ModelsWHEEL, LEG, & Handle Assembly ALL Models Except HW3000/L 25 Nm 18 lb. ftIndex Northshore Power Systems, LLC

hw400, HW3000, L specifications

Honeywell is renowned for its innovative solutions in various domains, including manufacturing, aerospace, and building technologies. Among its many offerings, the Honeywell L, HW3000, and HW400 series stand out for their advanced features, technologies, and characteristics, tailored to meet the evolving demands of industries worldwide.

The Honeywell L Series is recognized for its versatility and reliability in process control applications. Designed to accommodate a range of industrial needs, these controllers provide enhanced flexibility with modifiable configurations that suit diverse operating conditions. With advanced user interfaces, intuitive programming options, and robust execution capabilities, they optimize performance while simplifying system maintenance.

The HW3000 series takes innovation a notch higher, featuring cutting-edge process automation technologies. It leverages advanced algorithms and communication protocols, facilitating seamless integration with existing systems and enhancing overall efficiency. This series is designed for high-performance operations, offering real-time data monitoring and control. The HW3000's modular architecture allows for easy upgrades and scalability, making it ideal for businesses planning for growth.

On the other hand, the Honeywell HW400 series is engineered for precision and reliability. It is equipped with state-of-the-art sensors and control mechanisms that ensure optimal performance in demanding environments. The HW400 model emphasizes sustainability, incorporating energy-efficient technologies that align with global initiatives for greener operations. Users benefit from advanced diagnostics and predictive maintenance capabilities, which minimize downtime and enhance productivity.

All three series—L, HW3000, and HW400—share a commitment to security and data integrity. Honeywell incorporates cybersecurity measures to protect sensitive information and facilitate secure communications. Moreover, they embrace a user-friendly design philosophy, ensuring that operators can easily interface with the systems, regardless of their technical background.

In summary, Honeywell's L, HW3000, and HW400 series highlight the company’s dedication to innovation, efficiency, and reliability. With advanced technologies and robust features, these products cater to a wide range of industrial applications, making them essential tools for businesses aiming to optimize their operations. Whether for process control, automation, or precision management, Honeywell continues to provide solutions that drive success in the modern industrial landscape.