Guardian Technologies 02010-2, 04164-3 owner manual Drive Belt, Exercising the Generator

Page 17

Section 3 – Maintenance

Recreational Vehicle Generator

DANGER

Do not dispose of the battery in a fire. The bat- tery is capable of exploding. Storage batteries give off explosive hydrogen gas. This gas can form an explosive mixture around the battery for several hours after charging. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shatter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly venti- lated. Do not allow smoking, open flame, sparks, or any spark producing tools or equipment near the battery. Discharge static electricity from body before touching the battery by first touching a grounded metal surface.

A battery presents a risk of electrical shock and high short circuit current. The following precau- tions are to be observed when working on bat- teries:

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery;

Disconnect any charging source prior to connecting or disconnecting battery terminals; and

Do not use any jumper cables or booster battery to crank and start the generator engine. If any battery has discharged, remove it for recharging.

Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) or water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

3.10 MAJOR SERVICE MANUAL

To obtain a service manual for the generator, con- tact the nearest Authorized Service Dealer or, go to www.generac.com. Make sure to identify the MODEL NUMBER and SERIES.

3.11 DRIVE BELT

The engine drives the generator rotor by means of a pulley and drive belt arrangement. The drive belt and pulleys are warranted for the life of the generator. Drive belt tension was properly adjusted before the unit was shipped from the factory. If suspecting that the drive belt tension is incorrect, contact an Authorized Service Dealer.

3.12 EXERCISING THE GENERATOR

The manufacturer recommends starting and operat- ing the generator at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine.

3.13 OUT OF SERVICE PROCEDURE

‹3.13.1 REMOVAL FROM SERVICE

If the generator cannot be exercised every seven days, and it is to be out of service longer than 30 days, pre- pare the generator for storage as follows:

1.Start the engine and let it warm up.

2.Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.

3.While the engine is still warm from running, drain the oil completely. Refill the crankcase with SAE 10W-30 oil having API classification “For Service SF.”

4.Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase.

5.Remove the spark plug and pour two or three tablespoons of clean, fresh engine oil into the spark plug threaded openings. Reinstall and tighten the spark plug.

6.Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor.

7.Clean and wipe the entire generator.

15

Image 17
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationSpecifications SafetyGenerator Applicability Generator AC Connection System‹ 1.5.3 Fuel Consumption ‹ 1.5.2 Optional Propane Fuel System‹ 1.5.4 Engine OIL Requirements ‹ 1.5.6 GeneratorAutomatic Choke Gasoline only Generator Control PanelOptional Remote START/STOP Panel Starting the Generator Before Starting the Engine‹ 2.7.1 Letting the Engine Stabilize SUMMER/WINTER Heat Riser SystemStopping the Generator ‹ 2.9.2 High Temperature Switch ‹ 2.9. LOW OIL Pressure SwitchProtection Systems ‹ 2.8.1 do not Overload the Generator‹ 2.10.2 Operation in High Grass or Brush Additional InformationChecking the Engine OIL Level Changing the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR Cleaner‹ 3.3.1 Cleaning the Foam Precleaner Checking the Engine Spark Plug Clean AIR IntakeBattery Maintenance Cleaning the GeneratorFuel Filter Gasoline only Spark Arrestor Muffler‹ 3.13.1 Removal from Service OUT of Service ProcedureDrive Belt Exercising the Generator‹ 3.13.2 Return to Service Part  General Hazards   Fire Hazards  Equipment Description Purpose and Scope ManualGenerator Engine Operating Speed Standards Booklets0F1127 ‹ 2.1.2 Generator Support Location and Support‹ 2.1.1 Generator Location ‹ 2.1.4 Generator Restraint Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.4 Acoustics ‹ 2.2.3 Sound Insulating MaterialsTypical Noise Abatement ‹ 2.2.5 Compartment Floor Cutouts‹ 2.3.2 Cooling AIR Inlet Openings Cooling and Ventilating AIR‹ 2.3.1 Generator Airflow ‹ 2.3.3 Compensating for Restrictions ‹ 2.3.4 Testing the InstallationGasoline Fuel System ‹ 2.5.1 Parts not Included in Fuel System LP GAS Fuel System‹ 2.4.2 Generator Fuel Supply Line ‹ 2.5.5 Gaseous Carburetion ‹ 2.5.2 Some Important Considerations‹ 2.5.3 Vapor Withdrawal ‹ 2.5.6 Fuel Supply Lines Exhaust System‹ 2.5.7 Excess Flow Valve ‹ 2.5.8 Leakage Tests‹ 2.6.1 Mufflers and Spark Arrestors ‹ 2.6.3 Exhaust System Safety‹ 2.6.2 Type of Exhaust System ‹ 2.7.1 Electrical Junction BOX‹ 2.7.3 Generator AC Connections ‹ 2.7.2 Wiring‹ 2.7.7 Ground Fault Circuit Interrupters ‹ 2.7.6 Power Supply CordOptional Accessories Battery InstallationTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Electrical Data Exploded Views and Parts Lists Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists SCROLL, Flywheel Exploded Views and Parts Lists Ring SET, Piston DIA Exploded Views and Parts Lists MANIFOLD, Intake PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

02010-2, 04164-3 specifications

Guardian Technologies has made a significant impact in the air purification industry with its range of innovative products, particularly the models 02010-2 and 04164-3. These air purifiers are designed to enhance indoor air quality by leveraging advanced technologies, making them popular choices for both home and office environments.

The Guardian Technologies 02010-2 is an impressive model known for its portable design and effective purification capabilities. It features a 3-in-1 air cleaning system that includes a HEPA filter, a charcoal filter, and a UV-C light. The HEPA filter is essential for capturing allergens such as pollen, dust mites, and pet dander, making it ideal for allergy sufferers. The charcoal filter helps eliminate odors, capturing smoke and volatile organic compounds, while the UV-C light helps reduce germs and bacteria, ensuring a cleaner atmosphere.

This model is compact, allowing it to fit seamlessly into small spaces, while still providing powerful purification performance. With a whisper-quiet operation, it can be used in bedrooms or workspaces without causing disruption. Additionally, it features an adjustable fan speed, enabling users to customize the airflow according to their preference, along with an energy-efficient design that helps reduce power consumption.

On the other hand, the Guardian Technologies 04164-3 introduces a more advanced air purification system with similar foundational features but enhances the user experience with added functionalities. This model typically incorporates a combination of a HEPA filter and a UV-C light as well, but it often boasts smart capabilities. These may include an air quality sensor that helps monitor particulate levels in real-time, automatically adjusting the purification level when needed. This intelligent feature ensures that the air quality remains at optimal levels without requiring constant manual adjustments.

Both models prioritize user convenience, sporting features like filter replacement indicators, ensuring timely maintenance of the purification system. They are designed for ease of use and portability, allowing consumers to move them effortlessly from room to room.

In summary, Guardian Technologies’ models 02010-2 and 04164-3 stand out in the air purifier market due to their advanced filtration systems, ease of use, and smart technologies. These air purifiers are key investments for anyone looking to improve their indoor air quality effectively.