Guardian Technologies 02010-2, 04164-3 Protection Systems, ‹ 2.8.1 do not Overload the Generator

Page 12

Section 2 – Operation

Recreational Vehicle Generator

‹2.8.1 DO NOT OVERLOAD THE GENERATOR

Read the rated wattage/amperage capacity of the gen- erator on the generator data decal (see "Generator Identification").

Applying electrical loads in excess of the unit’s rated capacity will cause the engine/generator to automati- cally shut down.

To avoid overloading, add up the wattage of all con- nected electrical lighting, appliance, tool and motor loads. This total should not be greater than the generator’s rated wattage capacity.

Most lighting, appliance, tool and motor loads indicate their required watts on their nameplate or data plate. For light bulbs, simply note the wattage rating of the bulb.

If a load does not show its rated wattage, multiply that load’s rated VOLTS times AMPS to obtain

WATTS.

Induction type motors (such as those that run the vehicle’s furnace fan, refrigerator, air conditioner, etc.) need about 2-1/2 time more watts of power for starting than for running (for a few seconds dur- ing motor starting). Be sure to allow for this when connecting electrical loads to the generator. First, figure the watts needed to start electric motors in the system. To that figure, add the running watt- ages of other items that will be operated by the generator.

Do not apply heavy electrical loads for the first two or three hours of operation.

2.9PROTECTION SYSTEMS

‹2.9. LOW OIL PRESSURE SWITCH

Figure 2.4 – Low Oil Pressure and

High Temperature Switches

‹2.9.3 FIELD BOOST

The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.5). During engine cranking only, a positive DC (battery) voltage is deliv- ered through the diode, resistor, brushes and slip rings, and the generator rotor. Application of this voltage to the rotor “flashes the field” whenever it is started. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings.

Figure 2.5 – Field Boost Circuit

This switch (Figure 2.4) has normally closed (N.C.) contacts that are held open by engine oil pressure dur- ing cranking and operating. Should oil pressure drop below a preset level, switch contacts close, and the engine automatically shuts down. The unit should not be restarted until oil is added.

‹2.9.2 HIGH TEMPERATURE SWITCH

This switch (Figure 2.4), which has normally open (N.O.) contacts, is mounted near the oil filter. The contacts close if the temperature should exceed approximately 293º F (145º C), initiating an engine shutdown.

10

Image 12
Contents Air-cooled Recreational Vehicle Generators Authorized Service Dealer Location IntroductionPart II Installation Instructions Inside Front Cover Warning   Electrical Hazards  Generator Identification ModelSafety SpecificationsGenerator Applicability Generator AC Connection System‹ 1.5.2 Optional Propane Fuel System ‹ 1.5.3 Fuel Consumption‹ 1.5.4 Engine OIL Requirements ‹ 1.5.6 GeneratorGenerator Control Panel Optional Remote START/STOP PanelAutomatic Choke Gasoline only Before Starting the Engine Starting the GeneratorSUMMER/WINTER Heat Riser System Stopping the Generator‹ 2.7.1 Letting the Engine Stabilize ‹ 2.9. LOW OIL Pressure Switch ‹ 2.9.2 High Temperature SwitchProtection Systems ‹ 2.8.1 do not Overload the GeneratorAdditional Information Checking the Engine OIL Level‹ 2.10.2 Operation in High Grass or Brush Maintaining the Engine AIR Cleaner ‹ 3.3.1 Cleaning the Foam PrecleanerChanging the Engine OIL AND/OR OIL Filter Clean AIR Intake Checking the Engine Spark PlugCleaning the Generator Battery MaintenanceFuel Filter Gasoline only Spark Arrestor MufflerOUT of Service Procedure ‹ 3.13.1 Removal from ServiceDrive Belt Exercising the Generator‹ 3.13.2 Return to Service Part  General Hazards   Fire Hazards  Purpose and Scope Manual Equipment DescriptionGenerator Engine Operating Speed Standards Booklets0F1127 Location and Support ‹ 2.1.1 Generator Location‹ 2.1.2 Generator Support Generator Compartments ‹ 2.1.4 Generator Restraint‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.2.5 Compartment Floor Cutouts Typical Noise AbatementCooling and Ventilating AIR ‹ 2.3.1 Generator Airflow‹ 2.3.2 Cooling AIR Inlet Openings ‹ 2.3.4 Testing the Installation Gasoline Fuel System‹ 2.3.3 Compensating for Restrictions LP GAS Fuel System ‹ 2.4.2 Generator Fuel Supply Line‹ 2.5.1 Parts not Included in Fuel System ‹ 2.5.2 Some Important Considerations ‹ 2.5.3 Vapor Withdrawal‹ 2.5.5 Gaseous Carburetion Exhaust System ‹ 2.5.6 Fuel Supply Lines‹ 2.5.7 Excess Flow Valve ‹ 2.5.8 Leakage Tests‹ 2.6.3 Exhaust System Safety ‹ 2.6.1 Mufflers and Spark Arrestors‹ 2.6.2 Type of Exhaust System ‹ 2.7.1 Electrical Junction BOX‹ 2.7.2 Wiring ‹ 2.7.3 Generator AC Connections‹ 2.7.6 Power Supply Cord ‹ 2.7.7 Ground Fault Circuit InterruptersBattery Installation Optional AccessoriesPost Installation Tests Testing Under LoadBefore Initial START-UP Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionElectrical Data Electrical Data Exploded Views and Parts Lists Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists SCROLL, Flywheel Exploded Views and Parts Lists Ring SET, Piston DIA Exploded Views and Parts Lists MANIFOLD, Intake Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

02010-2, 04164-3 specifications

Guardian Technologies has made a significant impact in the air purification industry with its range of innovative products, particularly the models 02010-2 and 04164-3. These air purifiers are designed to enhance indoor air quality by leveraging advanced technologies, making them popular choices for both home and office environments.

The Guardian Technologies 02010-2 is an impressive model known for its portable design and effective purification capabilities. It features a 3-in-1 air cleaning system that includes a HEPA filter, a charcoal filter, and a UV-C light. The HEPA filter is essential for capturing allergens such as pollen, dust mites, and pet dander, making it ideal for allergy sufferers. The charcoal filter helps eliminate odors, capturing smoke and volatile organic compounds, while the UV-C light helps reduce germs and bacteria, ensuring a cleaner atmosphere.

This model is compact, allowing it to fit seamlessly into small spaces, while still providing powerful purification performance. With a whisper-quiet operation, it can be used in bedrooms or workspaces without causing disruption. Additionally, it features an adjustable fan speed, enabling users to customize the airflow according to their preference, along with an energy-efficient design that helps reduce power consumption.

On the other hand, the Guardian Technologies 04164-3 introduces a more advanced air purification system with similar foundational features but enhances the user experience with added functionalities. This model typically incorporates a combination of a HEPA filter and a UV-C light as well, but it often boasts smart capabilities. These may include an air quality sensor that helps monitor particulate levels in real-time, automatically adjusting the purification level when needed. This intelligent feature ensures that the air quality remains at optimal levels without requiring constant manual adjustments.

Both models prioritize user convenience, sporting features like filter replacement indicators, ensuring timely maintenance of the purification system. They are designed for ease of use and portability, allowing consumers to move them effortlessly from room to room.

In summary, Guardian Technologies’ models 02010-2 and 04164-3 stand out in the air purifier market due to their advanced filtration systems, ease of use, and smart technologies. These air purifiers are key investments for anyone looking to improve their indoor air quality effectively.