Guardian Technologies 02010-2, 04164-3 owner manual Description

Page 43

 

 

 

 

Section 6 — Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

Recreational Vehicle Generator

 

 

 

 

 

 

Regulator (Model 02010-2) – Drawing No. 0F1125-C

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

1

0D5694

1

CASTING, TWIN REGULATOR HOUSING

 

 

2

0F4795

4

SCREW PPHM SEMS M4-0.7 X 10

 

 

5

0F5022

1

SOLENOID COIL, 12VDC

 

 

6

0C6070

1

SPRING-SOLENOID PLUNGER

 

 

7

0C4680

1

PLUNGER LP REG. ASSY

 

 

8

0C4647

1

GASKET, SOLENOID

 

 

9

0C4643

1

INLET, TWIN REGULATOR NO HOLE

 

 

10

0D3973

1

PLUG, EXPANSION 16MM TWINREG

 

 

11

0E6183

1

ELBOW 90D STREET 1/2" BRASS

 

 

12

072683A

2

PLUG 1/8" NPTF PIPE

 

 

13

0D3308

2

WASHER FLAT 3.2MM ID X 10MM OD

 

 

14

070728

2

SCREW PFILHM M3-0.5 X 5

 

 

15

0C5764A

1

SPRING, REGULATOR 45N/M 29MM

 

 

16

0C4643A

1

INLET, TWIN REG 11.11 DIA.

 

 

17

0C6066

1

SEAL, INLET REGULATOR

 

 

18

0C5968

1

SUPPORT, INLET SEAL

 

 

19

0C5759

1

PIN, PIVOT ARM

 

 

20

0C5761

1

LEVER, REGULATOR

 

 

21

0C6069

1

GASKET, DIAPHRAGM

 

 

22

0C6731

1

RIVET .118 X .125 ALUMINUM

 

 

23

0C6067

1

SUPPORT, DIAPHRAGM

 

 

24

0C4706

1

DIAPHRAGM, TWIN REGULATOR

 

 

25

0C6068

1

CAP, DIAPHRAGM SUPPORT

 

 

26

0C5762

1

COVER,TWIN REGULATOR

 

 

27

045764

8

SCREW HHTT M4-0.7 X 8 BP

 

 

28

0C6606

1

BARBED STR 1/2" X 1/2" NPT

 

 

29

0E4170

1

CONNECTION 3/4"NPT - 3/8" 45D

 

 

30

0C5760

1

JET LP GN220 ENGINE

 

 

41

Image 43
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationGenerator AC Connection System SafetySpecifications Generator Applicability‹ 1.5.6 Generator ‹ 1.5.2 Optional Propane Fuel System‹ 1.5.3 Fuel Consumption ‹ 1.5.4 Engine OIL RequirementsOptional Remote START/STOP Panel Generator Control PanelAutomatic Choke Gasoline only Starting the Generator Before Starting the EngineStopping the Generator SUMMER/WINTER Heat Riser System‹ 2.7.1 Letting the Engine Stabilize ‹ 2.8.1 do not Overload the Generator ‹ 2.9. LOW OIL Pressure Switch‹ 2.9.2 High Temperature Switch Protection SystemsChecking the Engine OIL Level Additional Information‹ 2.10.2 Operation in High Grass or Brush ‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Checking the Engine Spark Plug Clean AIR IntakeSpark Arrestor Muffler Cleaning the GeneratorBattery Maintenance Fuel Filter Gasoline onlyExercising the Generator OUT of Service Procedure‹ 3.13.1 Removal from Service Drive Belt‹ 3.13.2 Return to Service Part  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating Speed0F1127 ‹ 2.1.1 Generator Location Location and Support‹ 2.1.2 Generator Support ‹ 2.2.1 Compartment Size Generator Compartments‹ 2.1.4 Generator Restraint ‹ 2.2.2 Compartment Construction‹ 2.2.4 Acoustics ‹ 2.2.3 Sound Insulating MaterialsTypical Noise Abatement ‹ 2.2.5 Compartment Floor Cutouts‹ 2.3.1 Generator Airflow Cooling and Ventilating AIR‹ 2.3.2 Cooling AIR Inlet Openings Gasoline Fuel System ‹ 2.3.4 Testing the Installation‹ 2.3.3 Compensating for Restrictions ‹ 2.4.2 Generator Fuel Supply Line LP GAS Fuel System‹ 2.5.1 Parts not Included in Fuel System ‹ 2.5.3 Vapor Withdrawal ‹ 2.5.2 Some Important Considerations‹ 2.5.5 Gaseous Carburetion ‹ 2.5.8 Leakage Tests Exhaust System‹ 2.5.6 Fuel Supply Lines ‹ 2.5.7 Excess Flow Valve‹ 2.7.1 Electrical Junction BOX ‹ 2.6.3 Exhaust System Safety‹ 2.6.1 Mufflers and Spark Arrestors ‹ 2.6.2 Type of Exhaust System‹ 2.7.3 Generator AC Connections ‹ 2.7.2 Wiring‹ 2.7.7 Ground Fault Circuit Interrupters ‹ 2.7.6 Power Supply CordOptional Accessories Battery InstallationInitial Start Post Installation TestsTesting Under Load Before Initial START-UPInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Electrical Data Exploded Views and Parts Lists Description Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists SCROLL, Flywheel Exploded Views and Parts Lists Ring SET, Piston DIA Exploded Views and Parts Lists MANIFOLD, Intake MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

02010-2, 04164-3 specifications

Guardian Technologies has made a significant impact in the air purification industry with its range of innovative products, particularly the models 02010-2 and 04164-3. These air purifiers are designed to enhance indoor air quality by leveraging advanced technologies, making them popular choices for both home and office environments.

The Guardian Technologies 02010-2 is an impressive model known for its portable design and effective purification capabilities. It features a 3-in-1 air cleaning system that includes a HEPA filter, a charcoal filter, and a UV-C light. The HEPA filter is essential for capturing allergens such as pollen, dust mites, and pet dander, making it ideal for allergy sufferers. The charcoal filter helps eliminate odors, capturing smoke and volatile organic compounds, while the UV-C light helps reduce germs and bacteria, ensuring a cleaner atmosphere.

This model is compact, allowing it to fit seamlessly into small spaces, while still providing powerful purification performance. With a whisper-quiet operation, it can be used in bedrooms or workspaces without causing disruption. Additionally, it features an adjustable fan speed, enabling users to customize the airflow according to their preference, along with an energy-efficient design that helps reduce power consumption.

On the other hand, the Guardian Technologies 04164-3 introduces a more advanced air purification system with similar foundational features but enhances the user experience with added functionalities. This model typically incorporates a combination of a HEPA filter and a UV-C light as well, but it often boasts smart capabilities. These may include an air quality sensor that helps monitor particulate levels in real-time, automatically adjusting the purification level when needed. This intelligent feature ensures that the air quality remains at optimal levels without requiring constant manual adjustments.

Both models prioritize user convenience, sporting features like filter replacement indicators, ensuring timely maintenance of the purification system. They are designed for ease of use and portability, allowing consumers to move them effortlessly from room to room.

In summary, Guardian Technologies’ models 02010-2 and 04164-3 stand out in the air purifier market due to their advanced filtration systems, ease of use, and smart technologies. These air purifiers are key investments for anyone looking to improve their indoor air quality effectively.