Guardian Technologies 004583-0 Automatic Idle Control, LOW OIL Pressure Shutdown System

Page 14

Section 2 – Operation

Portable Generator System

2.9 AUTOMATIC IDLE CONTROL

This feature is designed to greatly improve fuel economy. When this switch is turned “On,” the engine will only run at its normal fast governed engine speed when electrical load is connected. When the load is removed, the engine will run at a reduced speed of 2100 RPM. With the switch “Off,” the engine runs at the normal fast engine speed all the time. Always have the switch OFF when starting and stopping the engine.

2.10 COLD WEATHER OPERATION/DE-ICER

Under certain weather conditions (temperatures below 40° F (4°

C)and a high dew point), the engine may experience icing of the carburetor and/or the crankcase breather system. To eliminate this problem, this generator engine is fitted with a winter/summer valve. This directs hot air into the carburetor during cold weather operation. Always make sure the winter/summer valve is in the correct location relative to the weather conditions.

2.11LOW OIL PRESSURE SHUTDOWN SYSTEM

The engine is equipped with a low oil pressure sensor that shuts down the engine automatically when the oil pressure drops below 10 psi. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.

2.11.1 INITIAL START-UP

A delay built into the low oil shutdown system allows oil pressure to build during starting. The delay allows the engine to run for about 10 seconds before sensing oil pressure.

2.11.2 SENSING LOW OIL PRESSURE

If the system senses low oil pressure during operation, the engine shuts down.

2.11.3 RESTARTING

If trying to restart the engine within 10 seconds after it shuts down, the engine may NOT start. The system needs 5 to 10 seconds to reset.

If the engine is restarted after such a shutdown and the low oil pressure has not been corrected, the engine will run for about 10 seconds as described above and then stop.

2.12 CHARGING A BATTERY

DANGER

Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious injury.

DANGER

Do not permit smoking, open flame, sparks or any other source of heat around a battery. Wear protective goggles, rubber apron and rubber gloves when working around a battery. Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns. If spill occurs flush area with clear water immediately.

This generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. Do not use the unit to charge any 6 Volt batteries. Do not use the unit to crank an engine having a discharged battery.

This battery charger is a pulse type designed to provide a quality charge current into the battery. The voltage measured at the outlet should be 8-12 VDC. This is normal and does not indicate a faulty charging system.

To recharge 12 Volt batteries, proceed as follows:

Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. Do not use tap water.

If the battery is equipped with vent caps, make sure they are installed and are tight.

If necessary, clean battery terminals.

Connect battery charge cable connector plug to panel receptacle identified by the words "12-VOLT D.C."

Connect battery charge cable clamp with red handle to the positive

(+)battery terminal.

Connect battery charge cable clamp with black handle to the negative (-) battery terminal.

Start engine. Let the engine run while battery recharges. Engine idle control switch must be in off position for battery charging.

When battery has charged, shut down engine.

NOTE:

Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer's instructions carefully. Generally, a battery is considered to be at 100% state of charge when specific gravity of its fluid (as measured by hydrometer) is 1.260 or higher.

12

Image 14
Contents Ultra Source Operation Of Generator With Table of Contents Residential Portable Generator SystemTroubleshooting Electrical DataNever add fuel while unit is running IntroductionRead this Manual Thoroughly Important Safety Instructions Portable Generator SystemStandards Index Gasoline is extremely ExplosiveUnpacking AssemblyAccessory BOX Assembling the Wheel KITBattery Connection Handle AssemblyFuel Tank Tank holds 16 U.S. gallons of fuel Know the GeneratorOperation Portable Generator System 2 120 VAC, 20 AMP, Gfci Receptacle Cord Sets and Connection Plugs1 120 VAC, 20 AMP, Duplex Receptacle Grounding the Generator HOW to USE the Generator5 12 Volt DC, 10 AMP Receptacle 50 aDON’T Overload the Generator Connecting Electrical LoadsWattage Reference Guide Wattage requirementsSynthetic oil should only be used after first oil change Adding GasolineAdding Engine OIL To Start the Engine Stopping the EngineLOW OIL Pressure Shutdown System Charging a BatteryAutomatic Idle Control Generator Specifications Maintenance ScheduleProduct Specifications Engine SpecificationsGeneral Recommendations Service AIR Cleaner Replacing the Spark PlugGeneral To adjust valve clearanceInstall new valve cover gasket Re-attach the valve cover To check valve clearanceOther Storage Tips Store the unit in a clean, dry placeLong Term Storage Do not store gasoline from one season to anotherTroubleshooting Guide KIT Includes Transfer Switch InstallationPower Inlet Box Figure Tools RequiredDiameter Hole KnockoutMount Box Connect Emergency Circuits 50A/240VGenerator Control Panel Nema 14-50, 50 Amp Receptacle Nema 14-50, 50 Amp PlugUtility is now supplying power Transfer to Generator Power Source When Utility Power FailsTransfer Back to Utility Power Source Portable Generator System Portable Generator System Electrical Data Installation Diagram Drawing No G0907-B Engine Wiring Closest to Bearing Battery Charge Winding Ground BAR Page Description Page Description QTY Page QTY Description Exploded Views and Parts Lists Generator Drawing No G0742-A ADAPTOR, Engine Page SWITCH, Rocker -/0 Detail of Battery Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Warranty Portable Generator SystemEmission Control System Warranty Warranty Schedule Manual del Propietario Contenido Sistema de generador portátil residencial Sección 5 Instalación del conmutadorIntroducción LEA Detenidamente Este Manual¡ADVERTENCIA Sistema de generador portátilLa gasolina es extremadamente Explosiva Índice DE NormasAuxilios y obtenga inmediatamente ayuda médica Nfpa No , Nfpa Handbook of National Electric CodeCaja DE Accesorios DesempaqueMontaje Montaje DEL Juego DE LA RuedaConexión DE LA Batería Figura 2 Conjunto de la manijaSección 2 Operación Receptáculo de seguridad de 120 voltios, 30 amperiosFigura 6 Panel de control del motor Receptáculos DE 120 VCA Amperios Receptáculo DE 12 Voltios DE CC, 10 AmperiosConexión a Tierra DEL Generador Cómo Usar EL GeneradorNo Sobrecargue EL Generador Guía DE Referencia DEL Vataje Adición DE Aceite DEL MotorArranque DEL Motor Adición DE GasolinaOperación EN Climas FRÍOS/ Deshielador Detención DEL MotorControl Automatico DE Marcha DE Vacio Arranque InicialCuando termine de cargarse la batería apague el motor Carga DE LA BateriaRearranque Especificaciones DEL Generador Programa DE MantenimientoEspecificaciones DEL Producto Especificaciones DEL MotorRecomendaciones Generales Reemplazo DE LA Bujía Para limpiar o reemplazar el filtro de aire de papelReemplace la malla y la abrazadera de fijación Ajuste DE LA Holgura DE LA VálvulaSección 3 Mantenimiento Sistema de generador portátil Para revisar la holgura de la válvulaNo almacene gasolina de una temporada a otra Almacenamiento a Largo PlazoOtras Sugerencias Para EL Almacenamiento Guía DE Localización Y Resolución DE Problemas Ligero El motor vacilaHasta que el motor funcione suavemente Carga de la bateríaArtículos QUE ES Necesario Comprar Contenido DEL JuegoHerramientas Requeridas Caja de entrada de potencia FiguraOrificio de Material de calafateo de siliconaFigura 29 Prepare la caja para las conexiones Orificio CiegoFigura 33 Conecte los circuitos de emergencia USO DEL Generador Portátil Y DEL Conmutador DE Trasferencia ReceptáculoEnchufe Nema 14-50, de 50 amperios Receptáculo CC de 12 VoltiosTransferencia a LA Fuente DEL Suministro Eléctrico Sección 7 Garantía Sistema de generador portátil Generador auxiliar Programa DE LA Garantía

004583-0 specifications

Guardian Technologies 004583-0 is a noteworthy air purifying solution designed for effective indoor air quality management. This device is specifically designed to eliminate harmful particles and improve the overall environment in homes, offices, and other enclosed spaces. The primary objective of this air purifier is to provide users with cleaner air free from allergens, pollutants, and odors.

One of the standout features of the Guardian Technologies 004583-0 is its advanced True HEPA filtration system. This technology is capable of capturing 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This level of filtration is especially beneficial for allergy sufferers and individuals with respiratory issues. The inclusion of a pre-filter further helps to extend the life of the HEPA filter by trapping larger particles before they reach the HEPA layer.

Additionally, the Guardian Technologies 004583-0 incorporates UV-C light technology, which effectively kills airborne bacteria and viruses. This feature adds an extra layer of protection, ensuring that the air being circulated is not only free from particulates but also from harmful microorganisms. The synergistic effect of the HEPA filter and UV-C light makes this air purifier a robust solution for maintaining a healthy indoor atmosphere.

The design of the Guardian Technologies 004583-0 is another notable characteristic. It features a sleek and modern aesthetic, making it a fitting addition to any room's decor. Its compact size ensures that it can be placed in various locations without taking up excessive space. The device operates quietly, which means it can function efficiently in bedrooms, living rooms, or offices without causing distractions.

Furthermore, ease of use is a key element in the design of the Guardian Technologies 004583-0. It comes equipped with user-friendly controls that allow for straightforward operation and maintenance. Users can easily adjust fan speeds, engage the UV-C light, and monitor filter replacement indicators.

Overall, the Guardian Technologies 004583-0 stands out in the air purifier market due to its combination of efficient filtration, advanced technology, and user-friendly design. It presents an ideal solution for anyone seeking to improve their indoor air quality and create a healthier living or working environment.