Guardian Technologies 004583-0 owner manual Connect Emergency Circuits, 50A/240V

Page 24

Section 5 — Installation for Manual Transfer Switch

Portable Generator System

NOTE:

Balance must be maintained when moving circuit locations from main electrical distribution panel to emergency load center. Circuit breaker positions alternate buss bars vertically. Circuits sharing a neutral wire should either be moved together to adjacent positions in emergency load center or not moved. If you are unsure of proper procedure or if your installation differs from that described in this guide, consult a licensed professional at this time.

10a. Remove the main electrical distribution panel cover. Remove appropriate size knockout from the bottom or side of the main panel. (A 2-foot flexible conduit is pre-wired from the manual transfer switch with built-in load center). Remove threaded lock nut from conduit coupling. Feed all wires through knockout into main panel. Slip lock nut over wires and tighten securely onto conduit coupling (Figure 33).

Figure 33 - Connect Emergency Circuits

UL approved wire nuts are included with installation kit.

NOTE:

Circuits to be moved must be protected by same size breaker. For example, a 15 amp 120V circuit in emergency load center will replace a 15 amp 120V circuit in main panel.

NOTE:

Both grounded and ungrounded conductors for each circuit must be moved to the emergency panel and connected to to the new wiring from the emergency panel using supplied locknuts.

10b. In your main panel, remove the black (hot) wire from a circuit breaker that protects a circuit you want to have powered in the event of a power failure. Wire nut the black wire to the matching circuit lead wire from the emergency circuit breaker from load center in the transfer switch. (All circuit wires are color coded and labeled for easy identification). Repeat this process with remaining circuits to be powered by the generator.

Trace each black (hot) wire connected and wire nut the white (neutral) wire from the same Romex cable (circuit) to the matching circuit number on the white (neutral) wire from the emergency load center. Repeat for each circuit.

The emergency load center in the transfer switch supplies the following circuits: (5) 15A/120V, (5) 20A/120V, (1) 20A/240V, (1) 40A/240V and

(1) 50A/240V.

11.Install the 60 Amp double pole circuit breaker that you have purchased into main electrical distribution panel (Figure 34). This circuit breaker must be compatible with your main electrical distribution panel. It may be necessary to reposition remaining circuit breakers or remove circuit breakers that have been disconnected to accommodate the insertion of the 60 Amp double pole circuit breaker. Connect white wire to the main distribution panel neutral bar. Connect solid green wire to main electrical panel ground bar. Connect the black and red wires to the 60 Amp double pole circuit breaker. Replace electrical distribution panel cover.

Figure 34 - Connect Emergency Circuits

60

Your Portable Generator Manual

Transfer Switch is now installed.

NOTE:

If additional circuits are required to be protected.The manufacturer offers an additional 30A manual transfer switch and 30A Power Inlet Kit (Model 5341). Contact your place of purchase for availability.

22

Image 24
Contents Ultra Source Table of Contents Residential Portable Generator System TroubleshootingOperation Of Generator With Electrical DataIntroduction Read this Manual ThoroughlyNever add fuel while unit is running Important Safety Instructions Portable Generator SystemStandards Index Gasoline is extremely ExplosiveAssembly Accessory BOXUnpacking Assembling the Wheel KITBattery Connection Handle AssemblyKnow the Generator Operation Portable Generator SystemFuel Tank Tank holds 16 U.S. gallons of fuel Cord Sets and Connection Plugs 1 120 VAC, 20 AMP, Duplex Receptacle2 120 VAC, 20 AMP, Gfci Receptacle HOW to USE the Generator 5 12 Volt DC, 10 AMP ReceptacleGrounding the Generator 50 aConnecting Electrical Loads Wattage Reference GuideDON’T Overload the Generator Wattage requirementsAdding Gasoline Adding Engine OILSynthetic oil should only be used after first oil change To Start the Engine Stopping the EngineCharging a Battery Automatic Idle ControlLOW OIL Pressure Shutdown System Maintenance Schedule Product SpecificationsGenerator Specifications Engine SpecificationsGeneral Recommendations Service AIR Cleaner Replacing the Spark PlugTo adjust valve clearance Install new valve cover gasket Re-attach the valve coverGeneral To check valve clearanceStore the unit in a clean, dry place Long Term StorageOther Storage Tips Do not store gasoline from one season to anotherTroubleshooting Guide Transfer Switch Installation Power Inlet Box FigureKIT Includes Tools RequiredDiameter Hole KnockoutMount Box Connect Emergency Circuits 50A/240VGenerator Control Panel Nema 14-50, 50 Amp Receptacle Nema 14-50, 50 Amp PlugTransfer to Generator Power Source When Utility Power Fails Transfer Back to Utility Power SourceUtility is now supplying power Portable Generator System Portable Generator System Electrical Data Installation Diagram Drawing No G0907-B Engine Wiring Closest to Bearing Battery Charge Winding Ground BAR Page Description Page Description QTY Page QTY Description Exploded Views and Parts Lists Generator Drawing No G0742-A ADAPTOR, Engine Page SWITCH, Rocker -/0 Detail of Battery Tray Rubber Tank Mount MANUFACTURER’S Emission Control System Warranty Coverage Warranty Portable Generator SystemEmission Control System Warranty Warranty Schedule Manual del Propietario Contenido Sistema de generador portátil residencial Sección 5 Instalación del conmutadorIntroducción LEA Detenidamente Este Manual¡ADVERTENCIA Sistema de generador portátilÍndice DE Normas Auxilios y obtenga inmediatamente ayuda médicaLa gasolina es extremadamente Explosiva Nfpa No , Nfpa Handbook of National Electric CodeDesempaque MontajeCaja DE Accesorios Montaje DEL Juego DE LA RuedaConexión DE LA Batería Figura 2 Conjunto de la manijaSección 2 Operación Receptáculo de seguridad de 120 voltios, 30 amperiosFigura 6 Panel de control del motor Receptáculos DE 120 VCA Amperios Receptáculo DE 12 Voltios DE CC, 10 AmperiosCómo Usar EL Generador No Sobrecargue EL GeneradorConexión a Tierra DEL Generador Guía DE Referencia DEL Vataje Adición DE Aceite DEL MotorArranque DEL Motor Adición DE GasolinaDetención DEL Motor Control Automatico DE Marcha DE VacioOperación EN Climas FRÍOS/ Deshielador Arranque InicialCarga DE LA Bateria RearranqueCuando termine de cargarse la batería apague el motor Programa DE Mantenimiento Especificaciones DEL ProductoEspecificaciones DEL Generador Especificaciones DEL MotorRecomendaciones Generales Reemplazo DE LA Bujía Para limpiar o reemplazar el filtro de aire de papelAjuste DE LA Holgura DE LA Válvula Sección 3 Mantenimiento Sistema de generador portátilReemplace la malla y la abrazadera de fijación Para revisar la holgura de la válvulaAlmacenamiento a Largo Plazo Otras Sugerencias Para EL AlmacenamientoNo almacene gasolina de una temporada a otra Guía DE Localización Y Resolución DE Problemas El motor vacila Hasta que el motor funcione suavementeLigero Carga de la bateríaContenido DEL Juego Herramientas RequeridasArtículos QUE ES Necesario Comprar Caja de entrada de potencia FiguraOrificio de Material de calafateo de siliconaFigura 29 Prepare la caja para las conexiones Orificio CiegoFigura 33 Conecte los circuitos de emergencia USO DEL Generador Portátil Y DEL Conmutador DE Trasferencia ReceptáculoEnchufe Nema 14-50, de 50 amperios Receptáculo CC de 12 VoltiosTransferencia a LA Fuente DEL Suministro Eléctrico Sección 7 Garantía Sistema de generador portátil Generador auxiliar Programa DE LA Garantía

004583-0 specifications

Guardian Technologies 004583-0 is a noteworthy air purifying solution designed for effective indoor air quality management. This device is specifically designed to eliminate harmful particles and improve the overall environment in homes, offices, and other enclosed spaces. The primary objective of this air purifier is to provide users with cleaner air free from allergens, pollutants, and odors.

One of the standout features of the Guardian Technologies 004583-0 is its advanced True HEPA filtration system. This technology is capable of capturing 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This level of filtration is especially beneficial for allergy sufferers and individuals with respiratory issues. The inclusion of a pre-filter further helps to extend the life of the HEPA filter by trapping larger particles before they reach the HEPA layer.

Additionally, the Guardian Technologies 004583-0 incorporates UV-C light technology, which effectively kills airborne bacteria and viruses. This feature adds an extra layer of protection, ensuring that the air being circulated is not only free from particulates but also from harmful microorganisms. The synergistic effect of the HEPA filter and UV-C light makes this air purifier a robust solution for maintaining a healthy indoor atmosphere.

The design of the Guardian Technologies 004583-0 is another notable characteristic. It features a sleek and modern aesthetic, making it a fitting addition to any room's decor. Its compact size ensures that it can be placed in various locations without taking up excessive space. The device operates quietly, which means it can function efficiently in bedrooms, living rooms, or offices without causing distractions.

Furthermore, ease of use is a key element in the design of the Guardian Technologies 004583-0. It comes equipped with user-friendly controls that allow for straightforward operation and maintenance. Users can easily adjust fan speeds, engage the UV-C light, and monitor filter replacement indicators.

Overall, the Guardian Technologies 004583-0 stands out in the air purifier market due to its combination of efficient filtration, advanced technology, and user-friendly design. It presents an ideal solution for anyone seeking to improve their indoor air quality and create a healthier living or working environment.