Generac Power Systems 004917-2 Out, Exhaust Flange 2 Pipe, Pipe Muffler OUT, Washer Lock 3/8 SS

Page 44

Section 7 - Exploded Views and Parts

QUIETSOURCELiquid-cooled 30 kW Generators Muffler — Drawing No. 0E8766-B

2

16

20

8

15

1611

11

 

11

18

 

1

17

19

 

 

 

16

 

 

 

8

 

7

 

 

 

 

 

 

16

 

 

 

17

 

 

 

18

 

19

 

 

 

 

 

TO

 

 

 

COMPARTMENT

 

 

 

TO

 

 

 

MANIFOLD

 

11

4

22

 

17

 

 

 

 

 

 

 

 

10

 

 

 

21

 

 

 

6

3

TO

 

12

 

 

MANIFOLD

4

22

 

 

17

 

 

10

21

5

14

12

13

9

 

14

 

9

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

0E8616

1

MUFFLER 7" X 9" X 21" 2.5" IN &

11

080762

4

BOLT U 3/8-16 X 2.62

 

 

 

OUT

12

0E8816

2

EXHAUST FLANGE 2" PIPE

2

0E8727

1

PIPE MUFFLER OUT

13

085917

4

WASHER LOCK 3/8 SS

3

0E8822

1

WYE PIPE 2-1/2"

14

0D2611

4

SCREW HHC 3/8-16 X 1-3/4 SS

4

0E8821

2

EXHAUST ELBOW HSB (2"-2-1/2")

15

039253

2

SCREW HHC M8-1.25 X 20 G8.8

5

0E6465

1

EXHAUST PIPE LH 3.0L FORD HSB

16

022145

5

WASHER FLAT 5/16-M8 ZINC

6

0E6465A

1

EXHAUST PIPE RH 3.0L FORD HSB

17

022129

7

WASHER LOCK M8-5/16

7

0E5914

1

BRACKET MUFFLER 3.0L FORD

18

045771

3

NUT HEX M8-1.25 G8 YEL CHR

 

 

 

HSB

19

0C2454

4

SCREW TH-FRM M6-1 X 16 N WA

8

0E8726

2

STRAP MUFFLER

 

 

 

 

Z/JS

9

0E0170A

2

EXHAUST BLANKET 3.0L FORD

20

039288

1

SCREW HHC M8-1.25 X 55 G8.8

 

 

 

HSB

21

044149

2

GASKET EXHAUST RING

10

036797

2

BOLT U 5/16-18 X 2.25

22

022259

4

NUT HEX 5/16-18 STEEL

42 Generac® Power Systems, Inc.

Image 44
Contents Installation Authorized Service Dealer Location ‹ Operation and Maintenance‹ HOW to Obtain Service IntroductionTable of Contents General Hazards Electrical Hazards Transfer Switch GeneratorAutomatic System Operation Generator AC Connection Systems‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.3 LOW Coolant Level Switch Generator Fuel SystemUnpacking Lifting the GeneratorSpecifications Reconfiguring the Fuel System‹ 1.10.1 Generator Specifications ‹ 1.10.2 Engine SpecificationsTorque Specifications Before InstallationEngine OIL Recommendations Coolant RecommendationsGenerator Location Generator Mounting SupportBasic Standby Electric System ‹ 2.1.1 Nfpa StandardsTransfer Switch Signal Connections Emergency Circuit Isolation MethodTotal Circuit Isolation Method Generator AC Neutral Connections‹ 2.10.1 Vented Batteries Battery Installation‹ 2.9.2 GTS-TYPE ATS Using a Standard GTS Transfer Switch Preparation Before START-UP‹ 3.2.1 AUTO/OFF/MANUAL Switch ‹ 3.2.2 Fault Indicator LED‹ 3.2.5 SET Exercise Time Switch Control Console Components‹ 3.2.6 System Ready LED Manual Transfer START-UP Engine Governor AdjustmentsRetransfer and Shutdown Weekly Exercise Cycle Checking Fluid Levels Cooling SystemOverload Protection for Engine DC Electrical System ‹ 4.5.11 Changing the Engine AIR Cleaner ‹ 4.5.4 Inspect Cooling System‹ 4.5.5 Check Engine Coolant Level ‹ 4.5.6 Perform Visual InspectionMiscellaneous Maintenance ‹ 4.6.1 Cleaning the Generator‹ 4.6.2 Battery ‹ 4.5.12 Spark Plugs‹ 4.6.3 Battery Maintenance ‹ 4.6.4 Battery ReplacementScheduled Maintenance Service Maintenance Interval InformationLevel Maintenance Level Troubleshooting Points Problem Cause CorrectionCustomer Connection PCB J2 ICT LOS WLS HCT Starter Carrier Bolt Boot Battery Cable Battery Post Cover BaclkBattery Post Cover RED + Hold Down BatteryDetail Assy GRD Wire 99HSB ASSEMBLY,BASE-DOOR Ground WireDuct Intake MID AL Duct Discharge RH ALGenerac Power Systems, Inc Assy 2A 12V UL Battery Control BOX HSBCover Front Panel HSB Cover TOP Panel HSB512 Wire SET 3.0L Ford not Cover Flywheel Access Shown 0LHSBNot SHOWN-USED to Hold OIL Drain Assembly Washer Lock M12Frame Tank Coolant Recovery Radiator R-IN,L-OUTVenturi 3.0L Ford HSB Side Support Radiator HSBNER Weldment Mounting Base Flange Fuel InletAssy Regulator 3.0L NG or LPV Washer Flat 5/16 ZincLeads Rotor 390 15KW 1P Direct HSB 2.5L Ford Rotor 390 20KW 1P Direct HSB 2.5L FordRotor 390 25KW 1P Direct HSB 2.5L Ford Rotor 390 40KW 1P Direct HSB 3.9L ChryslerOUT Exhaust Flange 2 PipePipe Muffler OUT Washer Lock 3/8 SSELEMENT, AIR Cleaner Cover AIR CleanerTube AIR Intake 3.0L Ford Washer Flat M5Installation Diagram Quietsource Liquid-cooled 30 kW Generators This Warranty Shall not Apply to the Following

004917-2 specifications

Generac Power Systems 004917-2 is a noteworthy addition to the realm of home power solutions, designed to provide reliable backup power during outages and enhance energy management for residential users. This model is recognized for its robust engineering and advanced features, making it a preferred choice for homeowners seeking uninterrupted power supply.

One of the standout characteristics of the 004917-2 is its quiet operation, achieved through innovative noise-reduction technology. This feature ensures that users can enjoy a peaceful environment without the disruptive sounds often associated with traditional generators. The unit is designed not only for functionality but also for discretion, seamlessly blending into residential settings.

Built with a powerful engine, the 004917-2 delivers an impressive wattage capacity, ensuring that essential appliances such as refrigerators, lights, and heating systems can function smoothly during power outages. Its automatic transfer switch capability is a significant technological advancement, allowing the generator to detect power loss and activate without user intervention. This means that homeowners can have peace of mind knowing that their critical systems will remain operational when most needed.

Another notable feature of the Generac 004917-2 is its user-friendly control panel, equipped with digital indicators that provide real-time monitoring of the generator's performance. This interface allows users to easily assess power usage, fuel levels, and maintenance schedules, empowering them with the information necessary to manage their energy needs effectively.

Moreover, the 004917-2 is designed for fuel efficiency, incorporating eco-friendly technologies that optimize fuel consumption while delivering high power output. This design not only helps to reduce operational costs but also minimizes the environmental impact.

In terms of durability, the unit boasts a corrosion-resistant exterior that enhances its lifespan, making it suitable for various climates and conditions. Generac's commitment to quality assurance is evident in the rigorous testing that each model undergoes before reaching the consumer market.

In summary, the Generac Power Systems 004917-2 stands out as a reliable and efficient solution for homeowners looking for dependable backup power. With its quiet operation, powerful performance, automatic transfer capabilities, user-friendly interface, fuel efficiency, and robust construction, it meets the demands of modern energy use while offering peace of mind during unexpected outages.