Section 6 - Electrical Data

QUIETSOURCELiquid-cooled 30 kW Generators Wiring Diagram — Engine — Drawing No. 0E6199-E

PCB J2

1

767

2

765

3

769

4

766

5

768

6

0

7

N/C

8

14

PCB J1

1

56

2

86

3

15A

4

23

5

224

6

0

7

 

8

239

9

 

10

15E

11

85

12

14A

13

225

14

66

1

C1

0

2

0

3

0

4

0A

5

13

6

14A

7

15A

8

15E

9

14

10

224

11

225

12

239

 

86

16

14

16

16

NOTE:

 

 

 

 

 

 

SIZE (AWG)

 

ALL WIRES ARE 18 AWG 300

 

 

 

VOLT UL LISTED UNLESS

 

 

 

OTHERWISE NOTED AS SHOWN:

 

16

 

 

 

 

CC

JB

 

 

 

 

 

 

 

 

 

 

16

14

14

10

 

 

 

 

10

 

16

1

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

13

13

13

56

0

16

 

14

 

 

 

 

 

 

 

 

 

 

 

 

16

10

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

BAT

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

4

-

SM

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

10

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

LT

 

 

 

 

 

 

GND2

 

16

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

 

 

 

 

 

 

GND1

 

 

 

 

 

 

 

0A

 

 

 

 

 

 

 

 

 

0

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

FS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

HCT

 

 

 

 

 

 

1

85

 

 

 

 

 

0

1

BLK

 

 

 

 

 

 

 

 

WLS

 

 

 

 

 

 

 

RED

 

DEG

0

1

765

2

766

3

14

4

766

5

765

6

767

7

770

8

771

9

768

10

767

11

769

12

GOV

771

1

767

2

765

3

770

4

N/C

5

766

6

1416

16

14IM

016

449

16

 

1

 

4

 

6

 

2

449

 

 

 

 

 

3

5

 

 

 

 

 

 

 

 

 

14

 

IC

 

 

 

0

 

 

 

 

3

2 5 1

 

0

 

0

23

23

66

66

LEGEND:

 

LEGEND [CONT.]:

ALT -

D.C. CHARGE ALTERNATOR

HCT -

HIGH COOLANT TEMP SWITCH

BAT -

12VDC BATTERY

IC -

IGNITION COIL

C1 -

CONNECTOR 1 (ENGINE)

IM -

IGNITION MODULE (ON DISTRIBUTOR)

CC -

STARTER CONTACTOR

J-1 -

JUNCTION 1 (ON PCB)

DEG -

DRIVER ELEC. GOVERNOR

J-2 -

JUNCTION 2 (ON PCB)

FS -

FUEL SOLENOID

JB -

JUNCTION BLOCK (RUN POWER)

GND1-

GROUND (SENSING/LOW AMP)

LOS -

LOW OIL PRESSURE SWITCH

GND2-

GROUND (POWER/HIGH AMP)

SM -

STARTER MOTOR

GOV -

ELEC. GOVERNOR ACTUATOR

WLS -

COOLANT LEVEL SWITCH

Generac® Power Systems, Inc. 25

Image 27
Contents Installation Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceTable of Contents General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationGenerator Fuel System ‹ 1.7.2 High Coolant Temperature Switch‹ 1.7.1 LOW OIL Pressure Switch ‹ 1.7.3 LOW Coolant Level SwitchLifting the Generator Unpacking‹ 1.10.2 Engine Specifications SpecificationsReconfiguring the Fuel System ‹ 1.10.1 Generator SpecificationsCoolant Recommendations Torque SpecificationsBefore Installation Engine OIL Recommendations‹ 2.1.1 Nfpa Standards Generator LocationGenerator Mounting Support Basic Standby Electric SystemGenerator AC Neutral Connections Transfer Switch Signal ConnectionsEmergency Circuit Isolation Method Total Circuit Isolation MethodBattery Installation ‹ 2.9.2 GTS-TYPE ATS‹ 2.10.1 Vented Batteries Preparation Before START-UP Using a Standard GTS Transfer SwitchControl Console Components ‹ 3.2.1 AUTO/OFF/MANUAL Switch‹ 3.2.2 Fault Indicator LED ‹ 3.2.5 SET Exercise Time SwitchManual Transfer START-UP Engine Governor Adjustments Retransfer and Shutdown‹ 3.2.6 System Ready LED Weekly Exercise Cycle Cooling System Overload Protection for Engine DC Electrical SystemChecking Fluid Levels ‹ 4.5.6 Perform Visual Inspection ‹ 4.5.11 Changing the Engine AIR Cleaner‹ 4.5.4 Inspect Cooling System ‹ 4.5.5 Check Engine Coolant Level‹ 4.5.12 Spark Plugs Miscellaneous Maintenance‹ 4.6.1 Cleaning the Generator ‹ 4.6.2 Battery‹ 4.6.4 Battery Replacement ‹ 4.6.3 Battery MaintenanceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCustomer Connection PCB J2 ICT LOS WLS HCT Starter Carrier Bolt Hold Down Battery Boot Battery CableBattery Post Cover Baclk Battery Post Cover RED +Detail Duct Discharge RH AL Assy GRD Wire 99HSBASSEMBLY,BASE-DOOR Ground Wire Duct Intake MID ALGenerac Power Systems, Inc Cover TOP Panel HSB Assy 2A 12V UL BatteryControl BOX HSB Cover Front Panel HSB512 Washer Lock M12 Wire SET 3.0L Ford notCover Flywheel Access Shown 0LHSB Not SHOWN-USED to Hold OIL Drain AssemblyFrame Side Support Radiator HSB Tank Coolant RecoveryRadiator R-IN,L-OUT Venturi 3.0L Ford HSBNER Washer Flat 5/16 Zinc Weldment Mounting BaseFlange Fuel Inlet Assy Regulator 3.0L NG or LPVLeads Rotor 390 40KW 1P Direct HSB 3.9L Chrysler Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 25KW 1P Direct HSB 2.5L FordWasher Lock 3/8 SS OUTExhaust Flange 2 Pipe Pipe Muffler OUTWasher Flat M5 ELEMENT, AIR CleanerCover AIR Cleaner Tube AIR Intake 3.0L FordInstallation Diagram Quietsource Liquid-cooled 30 kW Generators This Warranty Shall not Apply to the Following

004917-2 specifications

Generac Power Systems 004917-2 is a noteworthy addition to the realm of home power solutions, designed to provide reliable backup power during outages and enhance energy management for residential users. This model is recognized for its robust engineering and advanced features, making it a preferred choice for homeowners seeking uninterrupted power supply.

One of the standout characteristics of the 004917-2 is its quiet operation, achieved through innovative noise-reduction technology. This feature ensures that users can enjoy a peaceful environment without the disruptive sounds often associated with traditional generators. The unit is designed not only for functionality but also for discretion, seamlessly blending into residential settings.

Built with a powerful engine, the 004917-2 delivers an impressive wattage capacity, ensuring that essential appliances such as refrigerators, lights, and heating systems can function smoothly during power outages. Its automatic transfer switch capability is a significant technological advancement, allowing the generator to detect power loss and activate without user intervention. This means that homeowners can have peace of mind knowing that their critical systems will remain operational when most needed.

Another notable feature of the Generac 004917-2 is its user-friendly control panel, equipped with digital indicators that provide real-time monitoring of the generator's performance. This interface allows users to easily assess power usage, fuel levels, and maintenance schedules, empowering them with the information necessary to manage their energy needs effectively.

Moreover, the 004917-2 is designed for fuel efficiency, incorporating eco-friendly technologies that optimize fuel consumption while delivering high power output. This design not only helps to reduce operational costs but also minimizes the environmental impact.

In terms of durability, the unit boasts a corrosion-resistant exterior that enhances its lifespan, making it suitable for various climates and conditions. Generac's commitment to quality assurance is evident in the rigorous testing that each model undergoes before reaching the consumer market.

In summary, the Generac Power Systems 004917-2 stands out as a reliable and efficient solution for homeowners looking for dependable backup power. With its quiet operation, powerful performance, automatic transfer capabilities, user-friendly interface, fuel efficiency, and robust construction, it meets the demands of modern energy use while offering peace of mind during unexpected outages.