Generac Power Systems 004917-2 Tube AIR Intake 3.0L Ford, Washer Flat M5, Conn, Washer Flat M10

Page 45

Section 7 - Exploded Views and Parts

QUIETSOURCELiquid-cooled 30 kW Generators

Air Cleaner — Drawing No. 0E8189

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

0E5193

1

PLATE AIR CLEANER ADAPTER

11

049226

8

WASHER LOCK M5

2

0E8200

1

TUBE AIR INTAKE 3.0L FORD

12

091526

4

SCREW PPHM M5-0.8 X 12 ZNC

3

0E8201

1

BRACKET AIR INTAKE 3.0L FORD

13

052619

4

SCREW HHC M5-0.8 X 20 G8.8

4

036434

1

BOLT U 5/16-18 X 2.09

14

051713

4

WASHER FLAT M5

5

0E0519A

1

ADAPTER, CARBURETOR W/PVC

15

051716

4

NUT HEX M5-0.8 G8 YEL CHR

 

 

 

CONN

16

022131

2

WASHER FLAT 3/8-M10

6

0C8127

1

ELEMENT, AIR CLEANER

17

046526

2

WASHER FLAT M10

7

0A5547

1

COVER - AIR CLEANER

18

051755

2

SCREW HHC M10-1.5 X 16 G8.8

8

062974

1

STUD TH 1/4-20 X 4-1/2 G2 ZNC

19

022145

2

WASHER FLAT 5/16-M8 ZINC

9

022127

1

NUT HEX 1/4-20 STEEL

20

022129

2

WASHER LOCK M8-5/16

10

037561

1

NUT WING 1/4-20 NYLK

21

022259

2

NUT HEX 5/16-18 STEEL

Generac® Power Systems, Inc. 43

Image 45
Contents Installation ‹ Operation and Maintenance Authorized Service Dealer Location‹ HOW to Obtain Service IntroductionTable of Contents General Hazards Electrical Hazards Generator Transfer SwitchAutomatic System Operation Generator AC Connection Systems‹ 1.7.1 LOW OIL Pressure Switch ‹ 1.7.2 High Coolant Temperature Switch‹ 1.7.3 LOW Coolant Level Switch Generator Fuel SystemLifting the Generator UnpackingReconfiguring the Fuel System Specifications‹ 1.10.1 Generator Specifications ‹ 1.10.2 Engine SpecificationsBefore Installation Torque SpecificationsEngine OIL Recommendations Coolant RecommendationsGenerator Mounting Support Generator LocationBasic Standby Electric System ‹ 2.1.1 Nfpa StandardsEmergency Circuit Isolation Method Transfer Switch Signal ConnectionsTotal Circuit Isolation Method Generator AC Neutral ConnectionsBattery Installation ‹ 2.9.2 GTS-TYPE ATS‹ 2.10.1 Vented Batteries Preparation Before START-UP Using a Standard GTS Transfer Switch‹ 3.2.2 Fault Indicator LED ‹ 3.2.1 AUTO/OFF/MANUAL Switch‹ 3.2.5 SET Exercise Time Switch Control Console ComponentsManual Transfer START-UP Engine Governor Adjustments Retransfer and Shutdown‹ 3.2.6 System Ready LED Weekly Exercise Cycle Cooling System Overload Protection for Engine DC Electrical SystemChecking Fluid Levels ‹ 4.5.4 Inspect Cooling System ‹ 4.5.11 Changing the Engine AIR Cleaner‹ 4.5.5 Check Engine Coolant Level ‹ 4.5.6 Perform Visual Inspection‹ 4.6.1 Cleaning the Generator Miscellaneous Maintenance‹ 4.6.2 Battery ‹ 4.5.12 Spark Plugs‹ 4.6.4 Battery Replacement ‹ 4.6.3 Battery MaintenanceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCustomer Connection PCB J2 ICT LOS WLS HCT Starter Carrier Bolt Battery Post Cover Baclk Boot Battery CableBattery Post Cover RED + Hold Down BatteryDetail ASSEMBLY,BASE-DOOR Ground Wire Assy GRD Wire 99HSBDuct Intake MID AL Duct Discharge RH ALGenerac Power Systems, Inc Control BOX HSB Assy 2A 12V UL BatteryCover Front Panel HSB Cover TOP Panel HSB512 Cover Flywheel Access Shown 0LHSB Wire SET 3.0L Ford notNot SHOWN-USED to Hold OIL Drain Assembly Washer Lock M12Frame Radiator R-IN,L-OUT Tank Coolant RecoveryVenturi 3.0L Ford HSB Side Support Radiator HSBNER Flange Fuel Inlet Weldment Mounting BaseAssy Regulator 3.0L NG or LPV Washer Flat 5/16 ZincLeads Rotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 25KW 1P Direct HSB 2.5L Ford Rotor 390 40KW 1P Direct HSB 3.9L ChryslerExhaust Flange 2 Pipe OUTPipe Muffler OUT Washer Lock 3/8 SSCover AIR Cleaner ELEMENT, AIR CleanerTube AIR Intake 3.0L Ford Washer Flat M5Installation Diagram Quietsource Liquid-cooled 30 kW Generators This Warranty Shall not Apply to the Following

004917-2 specifications

Generac Power Systems 004917-2 is a noteworthy addition to the realm of home power solutions, designed to provide reliable backup power during outages and enhance energy management for residential users. This model is recognized for its robust engineering and advanced features, making it a preferred choice for homeowners seeking uninterrupted power supply.

One of the standout characteristics of the 004917-2 is its quiet operation, achieved through innovative noise-reduction technology. This feature ensures that users can enjoy a peaceful environment without the disruptive sounds often associated with traditional generators. The unit is designed not only for functionality but also for discretion, seamlessly blending into residential settings.

Built with a powerful engine, the 004917-2 delivers an impressive wattage capacity, ensuring that essential appliances such as refrigerators, lights, and heating systems can function smoothly during power outages. Its automatic transfer switch capability is a significant technological advancement, allowing the generator to detect power loss and activate without user intervention. This means that homeowners can have peace of mind knowing that their critical systems will remain operational when most needed.

Another notable feature of the Generac 004917-2 is its user-friendly control panel, equipped with digital indicators that provide real-time monitoring of the generator's performance. This interface allows users to easily assess power usage, fuel levels, and maintenance schedules, empowering them with the information necessary to manage their energy needs effectively.

Moreover, the 004917-2 is designed for fuel efficiency, incorporating eco-friendly technologies that optimize fuel consumption while delivering high power output. This design not only helps to reduce operational costs but also minimizes the environmental impact.

In terms of durability, the unit boasts a corrosion-resistant exterior that enhances its lifespan, making it suitable for various climates and conditions. Generac's commitment to quality assurance is evident in the rigorous testing that each model undergoes before reaching the consumer market.

In summary, the Generac Power Systems 004917-2 stands out as a reliable and efficient solution for homeowners looking for dependable backup power. With its quiet operation, powerful performance, automatic transfer capabilities, user-friendly interface, fuel efficiency, and robust construction, it meets the demands of modern energy use while offering peace of mind during unexpected outages.